BS 5588-4:1998
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Fire precautions in the design, construction and use of buildings Code of practice for smoke control using pressure differentials
Hardcopy , PDF
30-06-2005
English
04-12-2002
Committees responsible
Foreword
1 Scope
2 References
3 Definitions
4 Analysis of the problem
5 System classification
6 Equipment
7 Actuation of pressure differential system
8 Electrical installations
9 Smoke control using pressure differentials
10 Design procedures
11 Installation and commissioning
12 Testing and maintenance
13 Documentation
14 Design calculations
Annex A (normative) Smoke control using pressure
differentials in atrium buildings
Annex B (normative) Test method for measuring the opening
force at a door
Annex C (normative) Interaction of pressure differential
systems with normal HVAC installations
Annex D (informative) Air leakage data
Annex E (normative) Test method for measuring the pressure
differentials under closed door conditions
Annex F (normative) Test method for measuring air velocities
Annex G (informative) Possible solutions for inability to
obtain design pressure differential
Annex H (informative) Design calculations requirements
List of references
Provides guidance on the design, installation, testing and maintenance in new and existing buildings of systems intended to limit the spread of smoke by means of pressure differentials.
Committee |
FSH/14
|
DevelopmentNote |
Supersedes BS 5588-4(1978), 92/39700 DC. (07/2002)
|
DocumentType |
Standard
|
Pages |
80
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
BS 5588-9:1989 | Fire precautions in the design, construction and use of buildings Code of practice for ventilation and air conditioning ductwork |
BS 7346-2:1990 | Components for smoke and heat control systems Specification for powered smoke and heat exhaust ventilators |
BS 5839-1:1988 | Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing |
BS 7671:1992 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS |
BS 5810:1979 | Code of practice for access for the disabled to buildings |
BS 5588-8:1988 | Fire precautions in the design, construction and use of buildings Code of practice for means of escape for disabled people |
BS 476-24:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of ventilation ducts |
BS 5720:1979 | Code of practice for mechanical ventilation and air conditioning in buildings |
BS 7346-1:1990 | Components for smoke and heat control systems Specification for natural smoke and heat exhaust ventilators |
BS 5588-7:1997 | Fire precautions in the design, construction and use of buildings Code of practice for the incorporation of atria in buildings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.