• Shopping Cart
    There are no items in your cart

BS 5871-2:2005

Current

Current

The latest, up-to-date edition.

Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Inset live fuel effect gas fires of heat input not exceeding 15 kW, and fire/back boilers (2nd and 3rd family gases)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-11-2007

€322.53
Excluding VAT

Committees responsible
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Exchange of information and planning
5 Appliances
6 Materials and components
7 Location
8 Appliance sizing
9 Ventilation
10 Flueing
11 Appliance fixing
12 Fire precautions
13 Gas supply
14 Electricity supplies and wiring
15 Ventilation (Fire/back boilers and fire/back
   circulators only)
16 Appliance fixing (Fire/back boilers and fire/back
   circulators only)
17 Fire precautions (Fire/back boilers and fire/back
   circulators only)
18 Water connections (Fire/back boilers and fire/back
   circulators only)
19 Commissioning
20 Instructions and use of fireguards
21 Advice to be given to the user
Annex A (informative) Calculation of required heat output
                      of a fire
Annex B (informative) Calculation of clearance flue flow
Bibliography

Describes installation and maintenance requirements for inset live fuel effect gas fires of heat input not exceeding 15 kW (16.6 kW based on gross calorific value) burning 2nd and 3rd family gases for the purpose of heating rooms or spaces in domestic or commercial premises.

Committee
GSE/30/-/4
DevelopmentNote
Supersedes 03/320605 DC & BS 5871-2(2001). (04/2005) Also available as part of BS KIT 174. (05/2005) Supersedes 07/301559372 DC. (01/2008)
DocumentType
Standard
Pages
56
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of BS 5871 specifies installation and maintenance requirements for inset live fuel effect gas fires of heat input not exceeding 15 kW (16.6 kW based on gross calorific value) burning 2nd and 3rd family gases for the purpose of heating rooms or spaces in domestic (see Note 5) or commercial premises. Combined appliances of the type where a fire is used in conjunction with a boiler or circulator are also covered in so far as the installation of the combined appliance is concerned. The standard is applicable to appliances intended for installation either: within a builder’s opening and/or fireplace recess and which may, additionally, be suitable for installation in a purpose designed metal flue box conforming to BS 715 and flue conforming to the constructional and temperature requirements of BS EN 1856-1 and BS EN 1856-2; or using a direct flue connection, if specified in the manufacturer’s instructions; or in the case of a room sealed appliance, using a flue terminal/air duct assembly supplied by the appliance manufacturer. This standard covers the selection of a suitable appliance, the ventilation and flueing requirements, and other measures necessary to ensure a safe installation. The central heating and/or hot water system connected to a combined appliance is not within the scope of this standard and reference should be made to BS 5449 (see Note 6) and BS 5546 for this part of such an installation. This standard is not applicable to mobile and portable appliances conforming to BS EN 449 or to appliances in touring caravans. Additional requirements for the installation of fire/back boilers and fire/back circulators are specified in Clauses 15, 16, 17 and 18. NOTE 1 Inset live fuel effect gas fires differ from decorative fuel effect gas appliances, which burn gas so as to simulate a solid fuel fire or produce other decorative effects, in that they incorporate a heat exchanger and restrict the passage of the products of combustion between the appliance firebed and the chimney or flue. The only decorative fuel effect gas appliances covered by this part of BS 5871 are those shown in Figure 1b) and detailed in 1d) of the commentary and recommendations on Clause 5 of this standard. NOTE 2 Unless the context requires otherwise, inset live fuel effect gas fires are hereinafter referred to as fires. NOTE 3 Heat inputs in this document are based on net calorific value. Figures based on gross calorific value are given in parenthesis where deemed necessary. See also Clause 5, commentary and recommendations g). NOTE 4 Attention is drawn to the foreword concerning the installation of used appliances. NOTE 5 As well as normally constructed dwellings, domestic premises include any permanently sited caravan holiday homes, residential park homes and permanently moored boats. See IGE/UP/8 [8]. NOTE 6 BS 5449 has been partly replaced by BS EN 12828 and BS EN 12831, and is to be withdrawn once BS EN 14336 and BS EN 14337 are published.

BS 5440-1:2008 Flueing and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases) Specification for installation of gas appliances to chimneys and for maintenance of chimneys
BS 7967-2:2005 Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers in the measurement of carbon monoxide and the determination of combustion performance
BS 7977-1(2009) : 2009 SPECIFICATION FOR SAFETY AND RATIONAL USE OF ENERGY OF DOMESTIC GAS APPLIANCES - PART 1: RADIANT/CONVECTORS
BS 6798:2014 Specification for selection, installation, inspection, commissioning, servicing and maintenance of gas-fired boilers of rated input not exceeding 70 kW net
BS 8660-1:2011 Gas-fired micro-cogeneration appliances of rated thermal input not exceeding 70 kW net Specification for selection, installation, inspection, commissioning, servicing and maintenance of Stirling engine micro-cogeneration appliances
BS 7967-3:2005 Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for responding to measurements obtained from electronic portable combustion gas analysers
BS 5440-2:2009 Flueing and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases) Specification for the installation and maintenance of ventilation provision for gas appliances
BS 6798:2009 Specification for installation and maintenance of gas-fired boilers of rated input not exceeding 70 kW net
BS 5546:2010 Specification for installation and maintenance of gas-fired water-heating appliances of rated input not exceeding 70 kW net
BS 7967-1:2005 Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for identifying and managing sources of fumes, smells, spillage/leakage of combustion products and carbon monoxide detector activation

BS 476-4:1970 Fire tests on building materials and structures Non-combustibility test for materials
BS 1289-1:1986 Flue blocks and masonry terminals for gas appliances Specification for precast concrete flue blocks and terminals
BS EN 1806:2006 Chimneys Clay/ceramic flue blocks for single wall chimneys Requirements and test methods
02/701494 DC : DRAFT FEB 2002 HEATING SYSTEMS IN BUILDINGS - DESIGN AND INSTALLATION OF DIRECT ELECTRICAL ROOM HEATING SYSTEMS
BS EN 13502:2002 Chimneys. Requirements and test methods for clay/ceramic flue terminals
BS 6700:1997 Specification for design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages
BS 7977-2:2003 Specification for safety and rational use of energy of domestic gas appliances Combined appliances. Gas fire/back boiler
BS 7435-2:1991 Fibre cement flue pipes, fittings and terminals Specification for heavy quality fibre cement flue pipes, fittings and terminals
02/701496 DC : DRAFT FEB 2002 EN 14336 HEATING SYSTEMS IN BUILDINGS - INSTALLATION AND COMMISSIONING OF THE WHOLE SYSTEM
BS EN 14336:2004 Heating systems in buildings. Installation and commissioning of water based heating systems
PD 6501-1:1982 The preparation of British Standards for building and civil engineering Guide to the types of British Standard, their aims, relationship, content and application
BS 6539:1984 Specification for fireguards for use with solid fuel appliances
BS 7977-1:2002 Specification for safety and rational use of energy of domestic gas appliances Radiant/convectors
BS EN 449 : 2002 SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - DOMESTIC FLUELESS SPACE HEATERS (INCLUDING DIFFUSIVE CATALYTIC COMBUSTION HEATERS)
BS 6461-1:1984 Installation of chimneys and flues for domestic appliances burning solid fuel (including wood and peat) Code of practice for masonry chimneys and flue pipes
BS EN 14337:2005 Heating systems in buildings. Design and installation of direct electrical room heating systems
BS 5482-2:1977 Domestic butane- and propane-gas-burning installations Installations in caravans and non-permanent dwellings
BS 7671(2001) : 2001 AMD 14905 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
BS 7860:1996 Specification for carbon monoxide detectors (electrical) for domestic use
BS 715:1993 Specification for metal flue pipes, fittings, terminals and accessories for gas-fired appliances with a rated input not exceeding 60 kW
BS EN 50379-3:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances
BS 5449:1990 Specification for forced circulation hot water central heating systems for domestic premises
BS EN 1443:2003 Chimneys. General requirements
CR 1472:1997 General guidance for the marking of gas appliances
BS EN 50291:2001 Electrical apparatus for the detection of carbon monoxide in domestic premises. Test methods and performance requirements
BS EN 1856-1:2009 Chimneys. Requirements for metal chimneys System chimney products
BS 6778:1986 Specification for fireguards for use with portable, free-standing or wall-mounted heating appliances
PD 6516:1987 Guide to guarding fires and heating appliances
BS EN 1856-2:2009 Chimneys. Requirements for metal chimneys Metal flue liners and connecting flue pipes
BS 7435-1:1991 Fibre cement flue pipes, fittings and terminals Specification for light quality fibre cement flue pipes, fittings and terminals

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.