Foreword
Committees responsible
Code of practice
Section one. General
1.0 Introduction
1.1 Scope
1.2 Definitions
1.3 Major symbols
1.4 Other materials
1.5 Design documents
1.6 Detailing
1.7 References to BS 5400
Section two. Limit state design
2.1 General principles and design methods
2.2 Loading
2.3 Temperature effects
2.4 Ultimate limit states
2.5 Serviceability limit states
Section three. Properties of materials and section
               properties
3.1 General
3.2 Welds and fasteners
3.3 Section properties
3.4 Deductions for holes
3.5 Limiting proportions of cross sections
3.6 Slender cross sections
Section four. Design of structural elements
4.1 General
4.2 Members in bending
4.3 Lateral torsional buckling
4.4 Plate girders
4.5 Web bearing, buckling and stiffener design
4.6 Axially loaded tension members
4.7 Compression members
4.8 Axially loaded members with moments
4.9 Members with biaxial moments
4.10 Empirical design rules for members in lattice
      frames and trusses
4.11 Additional provisions for gantry girders
4.12 Purlins and side rails
4.13 Column bases
4.14 Cased sections
4.15 Web openings
Section five. Continuous construction
5.1 General
5.2 Elastic design
5.3 Plastic design
5.4 Continuous beams
5.5 Portal frames
5.6 Multi-storey rigid frames: elastic design
5.7 Multi-storey rigid frames: plastic design
Section six. Connections
6.1 General recommendations
6.2 Fastener spacing and edge distances
6.3 Ordinary bolting
6.4 Friction grip fasteners
6.5 Pin connections
6.6 Weld detail and design
6.7 Holding-down bolts
Section seven. Loading tests
7.1 General
7.2 Test conditions
7.3 Test procedures
Appendices
A Formal statement of safety factor format adopted
      in BS 5950 : Part 1 to facilitate correlation with
      ISO 2394 and BS 5400 : Part 3
B Lateral torsional buckling of members subject to
      bending
C Compression strength: Perry strut formula
D Effective lengths of struts in simple construction
E Effective lengths of struts in rigid frames
F Frame instability
G Design of restrained members with an unrestrained
      compression flange
H Web buckling
Tables
1 Limit states
2 Load factors and combinations
3 Factor K for location of material and tensile
      stress
4 Maximum thickness for adequate notch thickness of
      parts subject to applied tensile stress
5 Deflection limits other than for pitched roof
      portal frames
6 Design strengths, py
7 Limiting width to thickness ratio
8 Strength reduction factors for slender elements
9 Effective length, LE, for beams
10 Effective length, LE, for cantilever of length L
11 Bending strength, pb, (in N/mm2) for rolled
      sections
12 Bending strength, pb, (in N/mm2) for welded
      sections
13 Use of m and n factors for members of uniform
      section
14 Slenderness factor v for flanged beams of uniform
      section
15 Slenderness correction factor, n, for members with
      applied loading substantially concentrated within
      the middle fifth of the unrestrained length
16 Slenderness correction factor, n, for members with
      applied loading other than as for table 15
17 Moment diagram between adjacent points of lateral
      restraint
18 Equivalent uniform moment factor, m
19 Bending strength, pb, (in N/mm2) for rolled
      sections with equal flanges
      (a) Py = 265 N/mm2
      (b) Py = 275 N/mm2
      (c) Py = 340 N/mm2
      (d) Py = 355 N/mm2
20 Slenderness correction factor, n, for standard
      load conditions
21 Critical shear strength, qcr (in N/mm2)
      (a) Py = 265 N/mm2
      (b) Py = 275 N/mm2
      (c) Py = 340 N/mm2
      (d) Py = 355 N/mm2
22 Basic shear strength, qb (in N/mm2)
      (a) Py = 265 N/mm2
      (b) Py = 275 N/mm2
      (c) Py = 340 N/mm2
      (d) Py = 355 N/mm2
23 Flange dependent shear strength factor, qf (in N/
      mm2)
      (a) Py = 265 N/mm2
      (b) Py = 275 N/mm2
      (c) Py = 340 N/mm2
      (d) Py = 355 N/mm2
24 Nominal effective length, LE, for a strut
25 Strut table selection
26 Type of section obtained for table 25
27 Compressive strength, Pc, (in N/mm2) for struts
28 Angle, channel and T-section struts
29 Empirical values for purlins
30 Empirical values for side rails
31 Minimum edge and end distances to fasteners
32 Strength of bolts in clearance holes
33 Bearing strength on connected parts for ordinary
      bolts in clearance holes, pbs
34 Bearing strength on parts connected by parallel
      shank friction grip fasteners, pbg
35 Maximum dimensions of holes
36 Design strength, pw
37 Comparison of partial safety factors
38 Limiting lambda for box sections of uniform wall
      thickness, including RHS
39 Equivalent uniform moment factor, mt
Figures
1 Staggered holes
2 Angles with holes in both legs
3 Dimensions of sections
4 Effective shear area of typical sections
5 End panel designed not using tension field action
6 End panel designed using tension field action
      (single stiffener)
7 End panel designed using tension field action
      (double stiffener)
8 Stiff bearing length
9 Dimensions of castellated sections
10 Haunch restraints
11 Subframes
11a Minimum edge and end distances
12 Joint length at splice
13 Pin-ended tension members
14 Welded end connections
15 Symmetrical fillet welds
16 Dimensions for symmetrical plate girders
17 Side stanchion
18 Side stanchion with restraints
19 Simple side stanchion with crane gantry
20 Compound side stanchion with crane gantry
21 Compound valley stanchion with crane gantry
22 Restraint coefficients for limited frame
23 Effective length ratio LE/L for a column in a
      rigid-jointed frame with unrestricted sidesway for
      k3 = infinity
24 Effective length ratio LE/L for a column in a
      rigid-jointed frame with unrestricted sidesway for
      k3 = 0
25 Effective length ratio LE/L for a column in a
      rigid-jointed frame with partial sway bracing of
      relative stiffness k3 = 1
26 Effective length ratio LE/L for a column in a
      rigid-jointed frame with partial sway bracing of
      relative stiffness k3 = 2
27 Critical buckling mode of frame braced against
      sidesway
28 Critical buckling mode of frame free to sway
29 Members restrained on tension flange
30 Typical haunch
31 Value of beta t
32 Intermediate moments

Gives recommendations for the design of structural steel work with hot rolled sections, flats, plates and hollow sections in buildings and allied structures.

Committee
CB/203
DevelopmentNote
Supersedes 87/15229 DC and 91/13069 DC. (03/2006)
DocumentType
Standard
Pages
126
PublisherName
British Standards Institution
Status
Superseded
Supersedes

BS 5950-5:1987 Structural use of steelwork in building Code of practice for design of cold formed sections
BS 4848-2:1975 Specification. Hot-rolled structural steel sections. Hollow sections
BS 4604-1:1970 SPECIFICATION FOR THE USE OF HIGH STRENGTH FRICTION GRIP BOLTS IN STRUCTURAL STEELWORK METRIC SERIES - PART 1: GENERAL GRADE
BS 4395-1:1969 Specification for high strength friction grip bolts and associated nuts and washers for structural engineering General grade
BS 6399-3(1988) : 1988 LOADING FOR BUILDINGS - PART 3: CODE OF PRACTICE FOR IMPOSED ROOF LOADS
ISO 2394:2015 General principles on reliability for structures
BS 5950-4:1982 Structural use of steelwork in building Code of practice for design of floors with profiled steel sheeting
BS CP3:CH5-2(1972) : AMD 7908 CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - LOADING - WIND LOADS
BS 5950-2:1985 Structural use of steelwork in building Specification for materials, fabrication and erection: hot rolled sections
BS 5400-3:1982 Steel, concrete and composite bridges Code of practice for design of steel bridges
BS 4604-2:1970 SPECIFICATION FOR THE USE OF HIGH STRENGTH FRICTION GRIP BOLTS IN STRUCTURAL STEELWORK - METRIC SERIES - HIGHER GRADE (PARALLEL SHANK)
BS 8110-1:1985 Structural use of concrete Code of practice for design and construction
BS 18-1:1970 Methods for tensile testing of metals Non-ferrous metals
BS 4395-2:1969 Specification for high strength friction grip bolts and associated nuts and washers for structural engineering Higher grade bolts and nuts and general grade washers
BS 6399-1:1984 Loading for buildings Code of practice for dead and imposed loads
BS 4848-4:1972 Hot-rolled structural steel sections Equal and unequal angles
BS 5400-10(1980) : 1980 STEEL CONCRETE AND COMPOSITE BRIDGES - PART 10: CODE OF PRACTICE FOR FATIGUE
BS 4848-5:1980 Hot-rolled structural steel sections Bulb flats
BS 18-4:1971 Methods for tensile testing of metals Steel tubes
BS 4395-3:1973 Specification for high strength friction grip bolts and associated nuts and washers for structural engineering Higher grade bolts (waisted shank), nuts and general grade washers

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.