• BS 6230:2011

    Current The latest, up-to-date edition.

    Specification for installation of gas-fired forced convection air heaters for commercial and industrial space heating (2nd and 3rd family gases)

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  31-07-2011

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Selection of equipment and pre-installation
    5 Installation
    6 Post-installation
    Annexes
    Annex A (informative) - Occupational exposure limit
    Annex B (informative) - Checks to be carried out prior
            to commissioning
    Annex C (informative) - Typical live run checks
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes the installation requirements for direct and indirect gas-fired forced convection air heaters for space heating that are designed for commercial or industrial applications and to which The Gas Appliances (Safety) Regulations 1995 apply.

    Scope - (Show below) - (Hide below)

    This British Standard specifies the installation requirements for direct and indirect gas-fired forced convection air heaters for space heating that are designed for commercial or industrial applications and to which The Gas Appliances (Safety) Regulations 1995 [1] apply.

    This British Standard applies to the installation and maintenance of appliances that are designed to utilize gases of Group H of the 2nd family (e.g. natural gas), gases of Group P of the 3rd family (e.g. propane) as well as gases of Group B of the 3rd family (e.g. butane) when supplied under the conditions of the third family pressure couple (see BSEN437:2003+A1:2009).

    NOTE1 This British Standard does not specifically cover LPG/air for which additional requirements might be necessary.

    This British Standard applies to the installation of direct gas-fired air heaters within the scope of BSEN525:2009 and to indirect gas-fired forced convection air heaters within the scope of BSEN621:2009, BSEN1020:2009 and, where appropriate, BSEN1196:1998. These standards cover air heaters having a net heat input not exceeding 300kW. This standard also applies to the installation of direct gas-fired air heaters within the scope of BS5990:2006 and to indirect gas-fired forced convection air heaters within the scope of BS5991:1998. These standards cover air heaters having a gross heat input greater than 330kW but not exceeding 2MW (1.8MW net).

    NOTE2 For the purposes of this British Standard, installation includes design, inspection and commissioning. It is recognized that each of the tasks can be performed at the same time by different persons.

    NOTE3 The ratio of gross to net heat input is approximately 1.11:1 for Group H (natural gas), 1.09:1 for Group P (propane) and 1.08:1 for Group B (butane).

    NOTE4 The ventilation rates in cm2/kW of heat input given in this British Standard are based on the net calorific value.

    This British Standard also applies to air heaters designed to supply make-up air, door curtain heaters, transportable air heaters and heat exchange modules (i.e. air heaters without a main air movement fan) where such heat exchange modules are used in environmental non-process applications such as air handling units. It also covers installation of heaters in areas where petroleum or other flammable heavier-than-air vapours can be present (see 5.1.2).

    It does not include the safety requirements for installation where flammable dusts, toxic gases or flammable lighter-than-air gases might be present in significant quantities.

    NOTE5 In such cases it is important that liaison takes place with the Health and Safety Executive.

    This British Standard does not apply to the installation of air heaters to which The Gas Appliances (Safety) Regulations 1995 [1] apply, or that are designed for the sole use in domestic premises.

    General Product Information - (Show below) - (Hide below)

    Committee GSE/30
    Development Note Supersedes BS 6230(2005) and 11/30229803 DC. (07/2011)
    Document Type Standard
    Publisher British Standards Institution
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 5925:1991 Code of practice for ventilation principles and designing for natural ventilation
    BS 476-23:1987 Fire tests on building materials and structures Methods for determination of the contribution of components to the fire resistance of a structure
    BS 5991:2006 Specification for indirect gas fired forced convection air heaters with rated heat inputs greater than 330 kW but not exceeding 2 MW for industrial and commercial space heating. Safety and performance requirements (excluding electrical requirements) (2nd family gases)
    BS EN 437 : 2003 TEST GASES - TEST PRESSURES - APPLIANCE CATEGORIES
    BS EN ISO 10380:2012 Pipework. Corrugated metal hoses and hose assemblies
    BS 5854:1980 Code of practice for flues and flue structures in buildings
    BS EN 1020:2009 Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products
    BS 8494:2007 Electronic portable and transportable apparatus designed to detect and measure carbon dioxide in indoor ambient air. Requirements and test methods
    BS EN 1196:2011 Domestic and non-domestic gas-fired air heaters. Supplementary requirements for condensing air heaters
    BS EN 621:2009 Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products
    BS EN 60079-10-1:2015 Explosive atmospheres Classification of areas. Explosive gas atmospheres
    BS 7967-5:2010 Carbon monoxide in dwellings and other premises and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers in non-domestic premises for the measurement of carbon monoxide and carbon dioxide levels and the determination of combustion performance
    BS EN 50543:2011 Electronic portable and transportable apparatus designed to detect and measure carbon dioxide and/or carbon monoxide in indoor ambient air. Requirements and test methods
    BS 476-20:1987 Fire tests on building materials and structures Method for determination of the fire resistance of elements of construction (general principles)
    BS 476-21:1987 Fire tests on building materials and structures Methods for determination of the fire resistance of loadbearing elements of construction
    BS EN 525:2009 Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW
    PD CEN/TR 1749:2014 European scheme for the classification of gas appliances according to the method of evacuation of the combustion products (types)
    BS 476-22:1987 Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective