Foreword
Cooperating organizations
Specification
Section one. General
1 Scope
2 Definitions
3 Nominal size
4 Marking
Section two. Materials and design
5 Materials
6 End connections
Section three. Performance
7 Order of tests
8 Test 1: high velocity test
9 Test 2: pressure differential required to open the
            valve
10 Test 3: pressure tightness under a low downstream
            pressure
11 Test 4: pressure tightness under a high downstream
            pressure
12 Test 5: verification that the valve has not jammed
            as the results of the application of a
            pressure of 16 bar during test 4
13 Test 6: resistance of the valve to a bending moment
14 Test 7: repeat of tests 2 to 5 with the bending
            moment removed
15 Test 8: strength of check valve body
16 Test 9: endurance test
Section four. Instructions
17 Instructions for installation and use
Appendix
A Methods of test
Tables
1 Nominal size
2 Bending moments for body bending test
Figure
1 Test apparatus

Sets out characteristics of check valves of nominal size up to and including DN 54 that are suitable for use at pressures up to 10 bar and temperatures up to 90 degrees C when installed in any orientation.

Committee
B/504
DevelopmentNote
Supersedes 79/10567 DC (09/2005)
DocumentType
Standard
Pages
12
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

BS 3456-102.21:1988 Specification for safety of household and similar electrical appliances. Particular requirements Storage water heaters
BS 6280:1982 Method of vacuum (backsiphonage) test for water-using appliances
BS 6282-4:1982 Devices with moving parts for the prevention of contamination of water by backflow Specification for combined check and anti-vacuum valves of nominal size up to and including DN 42
BS 6614:1985 Specification for safety devices and water supply connections for washing machines and dishwashers connected to the water supply mains
BS 6281-3:1982 Devices without moving parts for the prevention of contamination of water by backflow Specification for pipe interrupters of nominal size up to and including DN 42
BS 7206:1990 Specification for unvented hot water storage units and packages
08/30176707 DC : DRAFT APR 2008 BS 336 - SPECIFICATION FOR FIRE HOSE COUPLINGS AND ANCILLARY EQUIPMENT
BS 6644:1991 Specification for installation of gas-fired hot water boilers of rated inputs between 60 kW and 2 MW (2nd and 3rd family gases)
BS 6644(2005) : 2005 SPECIFICATION FOR INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70 KW (NET) AND 1.8 MW (NET) (2ND AND 3RD FAMILY GASES)
BS 6700(2006) : 2006 DESIGN, INSTALLATION, TESTING AND MAINTENANCE OF SERVICES SUPPLYING WATER FOR DOMESTIC USE WITHIN BUILDINGS AND THEIR CURTILAGES - SPECIFICATION
BS 6700:1997 Specification for design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages
BS 6282-3:1982 Devices with moving parts for the prevention of contamination of water by backflow Specification for in-line anti-vacuum valves of nominal size up to and including DN 42
BS 3456-102.71:1991 Specification for safety of household and similar electrical appliances. Particular requirements Dispensing appliances for food, drink and packaged consumer products
BS 1415-2:1986 Mixing valves Specification for thermostatic mixing valves
BS 6281-2:1982 Devices without moving parts for the prevention of contamination of water by backflow Specification for type B air gaps
BS 6282-2:1982 Devices with moving parts for the prevention of contamination of water by backflow Specification for terminal anti-vacuum valves of nominal size up to and including DN 54
03/310868 DC : DRAFT JUNE 2003 BS 6644 - SPECIFICATION FOR INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70KW (NET) AND 2MW (GROSS) (2ND AND 3RD FAMILY GASES)

BS 1387(1967) : LATEST SCREWED AND SOCKETED STEEL TUBES AND TUBULARS AND FOR PLAIN END STEEL TUBES SUITABLE FOR WELDING OR FOR SCREWING TO BS 21 PIPE THREADS
BS 6281-1:1982 Devices without moving parts for the prevention of contamination of water by backflow. Specification for type A air gaps
BS 6281-3:1982 Devices without moving parts for the prevention of contamination of water by backflow Specification for pipe interrupters of nominal size up to and including DN 42
BS 5412&5413-5(1976) : AMD 4591 SPECIFICATION FOR THE PERFORMANCE OF DRAW-OFF TAPS WITH METAL BODIES FOR WATER SERVICES - PHYSIO-CHEMICAL CHARACTERISTICS MATERIALS COATINGS
BS 6282-3:1982 Devices with moving parts for the prevention of contamination of water by backflow Specification for in-line anti-vacuum valves of nominal size up to and including DN 42
BS 6282-4:1982 Devices with moving parts for the prevention of contamination of water by backflow Specification for combined check and anti-vacuum valves of nominal size up to and including DN 42
BS 2872:1969 Specification for copper and copper alloys. Forging stock and forgings
BS 6280:1982 Method of vacuum (backsiphonage) test for water-using appliances
BS 4127-2:1972 Specification for light gauge stainless steel tubes. Metric units
BS 6281-2:1982 Devices without moving parts for the prevention of contamination of water by backflow Specification for type B air gaps
BS 4504-2:1974 Circular flanges for pipes, valves and fittings (PN designated) Copper alloy and composite flanges
BS 864-3:1975 Capillary and compression tube fittings of copper and copper alloy Compression fittings for polyethylene pipes
BS 6282-2:1982 Devices with moving parts for the prevention of contamination of water by backflow Specification for terminal anti-vacuum valves of nominal size up to and including DN 54

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.