1 Scope
2 Definitions
3 Dead loads
4 Imposed floor and ceiling loads
5 Reduction in total imposed floor loads
6 Imposed roof loads
7 Crane gantry girders
8 Dynamic loading (excluding wind)
9 Parapets and balustrades
10 Vehicle barriers for car parks
Tables
1 Occupancy class index
2 Reduction in total distributed imposed floor loads
with number of storeys
3 Reduction in total distributed imposed floor loads
on a supporting beam or girder with floor area
4 Horizontal loads on parapets and balustrades
5 Residential occupancy class
6 Institutional and educational occupancy class
(prisons, hospitals, schools, colleges)
7 Public assembly occupancy class (halls, auditoria,
restaurants, museums, libraries, non-residential
clubs, theatres, broadcasting studios, grandstands)
8 Offices occupancy class (offices, banks)
9 Retail occupancy class (shops, departmental stores,
supermarkets)
10 Industrial occupancy class (workshops, factories)
11 Storage occupancy class (warehouses)
12 Vehicular occupancy class (garages, car parks,
vehicle access ramps)
Gives dead and minimum recommended imposed loads. Applies to new buildings, alterations to existing structures and construction on change of use.
Committee |
B/525/1
|
DevelopmentNote |
REPLACES CP 3: CHAPTER V: PART 1: 1967, PARTIALLY REPLACED BY BS 6399: PART 3: 1988
|
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
BS 5628-2:1985 | Code of practice for use of masonry Structural use of reinforced and prestressed masonry |
BS 5950-9:1994 | Structural use of steelwork in building Code of practice for stressed skin design |
BS 8103-3:1996 | Structural design of low-rise buildings Code of practice for timber floors and roofs for housing |
DD ENV 1992-1.1 : DRAFT MAY 1992 | EUROCODE 2: DESIGN OF CONCRETE STRUCTURES - GENERAL RULES FOR BUILDINGS (TOGETHER WITH UNITED KINGDOM NATIONAL APPLICATION DOCUMENT) |
BS 5950-1:1985 | Structural use of steelwork in building Code of practice for design in simple and continuous construction: hot rolled sections |
BS 5502-22:1993 | Buildings and structures for agriculture Code of practice for design, construction and loading |
BS 5385-5:1990 | Wall and floor tiling Code of practice for the design and installation of terrazzo tile and slab, natural stone and composition block floorings |
BS 5534-1:1978 | Code of practice for slating and tiling. Design |
BS 5950-2:1985 | Structural use of steelwork in building Specification for materials, fabrication and erection: hot rolled sections |
BS 5950-6(1995) : 1995 | STRUCTURAL USE OF STEELWORK IN BUILDING - PART 6: CODE OF PRACTICE FOR DESIGN OF LIGHT GAUGE PROFILED STEEL SHEETING |
BS 5268-6.1(1988) : 1988 | STRUCTURAL USE OF TIMBER - CODE OF PRACTICE FOR TIMBER FRAME WALLS - DWELLINGS NOT EXCEEDING THREE STOREYS |
BS 5628-2:1995 | Code of practice for use of masonry Structural use of reinforced and prestressed masonry |
BS 1139-3:1994 | Metal scaffolding Specification for prefabricated mobile access and working towers |
BS 5973:1990 | Code of practice for access and working scaffolds and special scaffold structures in steel |
BS 5268-2:1991 | Structural use of timber Code of practice for permissible stress design, materials and workmanship |
BS 4076:1989 | Specification for steel chimneys |
BS 5385-5:1994 | Wall and floor tiling Code of practice for the design and installation of terrazzo tile and slab, natural stone and composition block floorings |
BS 5973:1993 | Code of practice for access and working scaffolds and special scaffold structures in steel |
BS 5268-2:1996 | Structural use of timber Code of practice for permissible stress design, materials and workmanship |
BS 5268-2(1989) : LATEST | STRUCTURAL USE OF TIMBER - CODE OF PRACTICE FOR PERMISSIBLE STRESS DESIGN, MATERIALS AND WORKMANSHIP |
BS 5534-1:1990 | Code of practice for slating and tiling Design |
BS 5950-1:1990 | Structural use of steelwork in building Code of practice for design in simple and continuous construction: hot rolled sections |
BS 8110-1:1997 | Structural use of concrete Code of practice for design and construction |
BS 6180:1995 | Code of practice for barriers in and about buildings |
BS 4994:1987 | Specification for design and construction of vessels and tanks in reinforced plastics |
BS 5669-5:1989 | Particleboard Code of practice for the selection and application of particleboards for specific purposes |
BS 5977-1:1981 | Lintels Method for assessment of load |
BS 5502-22:1987 | Buildings and structures for agriculture Code of practice for design, construction and loading |
BS 8110-1:1985 | Structural use of concrete Code of practice for design and construction |
BS 5950-5:1987 | Structural use of steelwork in building Code of practice for design of cold formed sections |
BS 5268-7.6(1990) : 1990 | STRUCTURAL USE OF TIMBER - PART 7: RECOMMENDATION FOR THE CALCULATION BASIS FOR SPAN TABLES - SECTION 7.6: PURLINS SUPPORTING RAFTERS |
BS 6399-3(1988) : 1988 | LOADING FOR BUILDINGS - PART 3: CODE OF PRACTICE FOR IMPOSED ROOF LOADS |
BS 4841-3:1987 | Rigid polyurethane (PUR) and polyisocyanurate (PIR) foam for building applications Specification for two types of laminated board (roofboards) with auto-adhesively bonded reinforcing facings for use as roofboard thermal insulation for built-up roofs |
BS 8103-4:1995 | Structural design of low-rise buildings Code of practice for suspended concrete floors for housing |
BS 5385-3:1989 | Wall and floor tiling Code of practice for the design and installation of ceramic floor tiles and mosaics |
BS 8118-1:1991 | Structural use of aluminium Code of practice for design |
BS 8093:1991 | Code of practice for the use of safety nets, containment nets and sheets on constructional works |
BS 5268-3:1985 | Structural use of timber Code of practice for trussed rafter roofs |
BS 5427-1:1996 | Code of practice for the use of profiled sheet for roof and wall cladding on buildings Design |
BS 8201:1987 | Code of practice for flooring of timber, timber products and wood based panel products |
BS 7491-3:1994 | Glass fibre reinforced plastics cisterns for cold water storage Specification for sectional tanks |
PD 6529:1990 | Report on a new approach for design loads for buildings |
I.S. 325-2:1995 | CODE OF PRACTICE FOR USE OF MASONRY - PART 2: MASONRY CONSTRUCTION |
BS 6661:1986 | Guide for design, construction and maintenance of single-skin air supported structures |
BS 6767-1:1992 | Transportable accommodation units Recommendations for design and construction |
BS 5234-1:1992 | Partitions (including matching linings) Code of practice for design and installation |
BS 8102:1990 | Code of practice for protection of structures against water from the ground |
BS 5628-3:1985 | Code of practice for use of masonry Materials and components, design and workmanship |
BS 5975:1996 | Code of practice for falsework |
BS 5950-4:1994 | STRUCTURAL USE OF STEELWORK IN BUILDING - PART 4: CODE OF PRACTICE FOR DESIGN OF COMPOSITE SLABS WITH PROFILED STEEL SHEETING |
BS 6399-3(1988) : 1988 | LOADING FOR BUILDINGS - PART 3: CODE OF PRACTICE FOR IMPOSED ROOF LOADS |
BS CP3:CH5-2(1972) : AMD 7908 | CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - LOADING - WIND LOADS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.