• BS 6724(1997) : 1997

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE

    Available format(s):  Hardcopy, PDF

    Superseded date:  30-04-2016

    Language(s):  English

    Published date:  01-01-2008

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Voltage designation
    5 Conductors
    6 Insulation
    7 Identification of cores
    8 Laying-up
    9 Bedding
    10 Armour
    11 Oversheath
    12 Cable marking
    13 End sealing
    14 Schedule of tests
    15 Test conditions
    16 Routine tests
    17 Sample tests
    18 Type tests
    Annex A (informative) Recommendations for the selection and
                          operation of cables
    Annex B (informative) Recommendations for the installation of
                          cables
    Annex C (informative) Information to be provided with enquiry
                          or order
    Annex D (normative) Measurement of thickness
    Annex E (normative) Abrasion test
    Annex F (normative) Insulation resistance constant test
                          on oversheath
    Annex G (normative) Armour wire tests
    Annex H (normative) Resistance of conductor and armour
    Annex J (normative) Test for shrinkage of sheath on cable
    Annex K (normative) Voltage test on completed cables
    Annex L Spare
    Annex M (normative) Compatibility test
    Annex N (informative) Gross cross-sectional area of armour
    Annex P (informative Notes on type tests
    Annex Q (informative) Guide to use
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines requirements for constructing and establishes test methods for armoured cables having thermosetting insulation of rated voltages 600/1000 V and 1900/3300 V for production of lower levels of smoke and corrosive products when exposed to fire comparable with cables conforming to BS 5467.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20
    Development Note Supersedes BS 6724(1990), 96/202305 DC and 02/206303 DC. (04/2004) 1997 Edition Re-issued in June 2008 & incorporates AMD 3 2008. Supersedes 07/30169735 DC. (06/2008) Superseded by BS 6724(2016) but remains current and will be withdrawn on 30.04.2017. (05/2016)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 7655-6.1(1994) : 1994 SPECIFICATION FOR INSULATING AND SHEATHING MATERIALS FOR CABLES - THERMOPLASTIC SHEATHING COMPOUNDS HAVING LOW EMISSION OF CORROSIVE GASES, AND SUITABLE FOR USE IN CABLES HAVING LOW EMISSION OF SMOKE WHEN AFFECTED BY FIRE - GENERAL APPLICATION THERMOPLASTIC TYPES
    BS EN 61034-2 : 2005 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS PART 2: TEST PROCEDURE AND REQUIREMENTS
    BS 7671:1992 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
    BS EN 60332-1-2 : 2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004)
    BS EN 50267-2-1:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures Determination of the amount of halogen acid gas - Determination of the amount of halogen acid gas
    BS EN 60228:2005 Conductors of insulated cables
    BS EN 60811-1-1:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
    BS EN 60811-1-3:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test
    BS EN 10244-2:2009 Steel wire and wire products. Non-ferrous metallic coatings on steel wire Zinc or zinc alloy coatings
    BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
    HD 308 S2:2001 Identification of cores in cables and flexible cords
    IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
    BS 7655-1.3:1993 Specification for insulating and sheathing materials for cables. Elastomeric insulating compounds XLPE
    BS EN 62230 : 2007 ELECTRIC CABLES - SPARK-TEST METHOD
    IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
    BS EN 60811-1-2:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods
    BS 7655-1.2(1993) : 1993 INSULATING AND SHEATHING MATERIALS FOR CABLES - ELASTOMERIC INSULATING COMPOUNDS - GENERAL 90 DEGREE C APPLICATION
    BS EN 50363-5 : 2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS
    BS EN 50266-2-4:2001 Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables. Procedures Category C
    BS EN 10002-1:2001 Tensile testing of metallic materials Method of test at ambient temperature
    BS EN 50396 : 2005 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective