BS 6811-3.8(1993) : 1993 AMD 8891

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

WINDING WIRES - SPECIFICATIONS FOR PARTICULAR TYPES OF ENAMELLED ROUND COPPER WINDING WIRES - POLYIMIDE ENAMELLED ROUND COPPER WIRE, CLASS 220

Superseded date

15-11-1995

Superseded by

BS EN 60317-7:1995

Published date

23-11-2012

Sorry this product is not available in your region.

Committees responsible
National foreword
Foreword
1. Scope
2. Normative references
3. Definitions and general notes on methods of test
4. Dimensions
5. Electrical resistance
6. Elongation
7. Springiness
8. Flexibility and adherence
9. Heat shock
10. Cut-through
11. Resistance to abrasion
12. Resistance to solvents
13. Breakdown voltage
14. Continuity of insulation
15. Temperature index
16. Resistance to refrigerants
17. Solderability
18. Heat or solvent bonding
19. Dielectric dissipation factor
20. Resistance to transformer oil
21. Loss of mass
22. High temperature failure
30. Packaging
Annex ZA. (normative) Other international publications
          quoted in this standard with the references
          of the relevant European publications
National annex NA (informative) Cross-references

Specifies the requirements of enamelled round copper winding wire of class 220 with a sole coating based on polyimide resin. Covers the following range of nominal conductor diameters: 0,020 mm up to and including 2,000 mm (Grade 1); 0,020 mm up to and including 5,000 mm (Grade 2). Coverage includes dimensions, electrical resistance, heat shock, resistance to abrasion, solderability, resistance to solvents and high temperature failure. BS AMD 8891 RENUMBERS THIS STANDARD TO BS EN 60317 PT7

Committee
CIL/55
DevelopmentNote
Renumbered and superseded by BS EN 60317-7. (10/2005)
DocumentType
Standard
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

IEC 60317-0-1:2013 Specifications for particular types of winding wires - Part 0-1: General requirements - Enamelled round copper wire

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.