    Sampling for Legionella bacteria in water systems. Code of practice

    Available format(s):  Hardcopy, PDF

    Superseded date:  21-02-2022

    Language(s):  English

    Published date:  30-11-2008

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    Section 1: General
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Risk assessments
    5 Safety of sampling personnel
    6 Survey and sampling
    7 Apparatus and materials
    Section 2: Routine sampling
    8 Sampling procedures
    9 Sample transport and storage
    Section 3: Sampling for outbreak and other
               investigations
    10 General
    11 Safety of sampling personnel
    12 Apparatus and materials
    13 Sampling procedures
    14 Other sources
    Annexes
    Annex A (informative) - Label and sample collection form
            information
    Bibliography

    Abstract - (Show below) - (Hide below)

    Provides recommendations and guidance on the sampling of water and related materials for determination of the presence of organisms of the genus Legionella. Applies to sampling artificial water systems and also gives methods for sampling of biofilms and sediments that might be present in water systems.

    Scope - (Show below) - (Hide below)

    This British Standard gives recommendations and guidance on the sampling of water and related materials for determination of the presence of organisms of the genus Legionella. it is applicable to sampling artificial water systems and also gives methods for sampling of biofilms and sediments that might be present in water systems. Some of the same sampling principles can be applied to natural water systems.

    The standard is applicable to both sampling for routine monitoring and in outbreak investigations. For the latter, recommendations and guidance on the selection of sampling points are given. The rationale for the selection of sampling points for particular situations is also discussed.

    This British Standard is intended for use by all those involved in water sampling for legionellae including the persons taking samples on site and their employers.

    General Product Information - (Show below) - (Hide below)

    Committee EH/3/4
    Development Note Supersedes BS 7592(1992) and 08/30161147 DC. (12/2008)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    EN 15154-1:2006 Emergency safety showers - Part 1: Plumbed-in body showers for laboratories
    BS 8515(2009) : 2009 RAINWATER HARVESTING SYSTEMS - CODE OF PRACTICE
    BS 8552:2012 Sampling and monitoring of water from building services closed systems. Code of practice
    ISO 5667-21:2010 Water quality Sampling Part 21: Guidance on sampling of drinking water distributed by tankers or means other than distribution pipes
    BS 8525-1:2010 Greywater systems Code of practice
    BS 8558:2011 Guide to the design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages. Complementary guidance to BS EN 806
    BS EN 15154-1:2006 Emergency safety showers Plumbed-in body showers for laboratories
    BS 8580:2010 Water quality. Risk assessments for Legionella control. Code of practice
    BS 8554:2015 Code of practice for the sampling and monitoring of hot and cold water services in buildings
    BS 8558:2015 Guide to the design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages. Complementary guidance to BS EN 806
    PD 855468:2015 Guide to the flushing and disinfection of services supplying water for domestic use within buildings and their curtilages
    BS ISO 5667-21:2010 Water quality. Sampling Guidance on sampling of drinking water distributed by tankers or means other than distribution pipes

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 6068-4.18(2004) : 2004 WATER QUALITY - DETECTION AND ENUMERATION OF LEGIONELLA - PART 2: DIRECT MEMBRANE FILTRATION METHOD FOR WATERS WITH LOW BACTERIAL COUNTS
    BS 6068-4.12:1998 Water quality. Microbiological methods Detection and enumeration of Legionella
    BS EN ISO 19458:2006 Water quality. Sampling for microbiological analysis
    ISO 11731:2017 Water quality — Enumeration of Legionella
    BS EN ISO 11731-2:2008 Water quality. Detection and enumeration of Legionella Direct membrane filtration method for waters with low bacterial counts
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective