BS 7870-3.40:2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for distribution cables of rated voltage 0.6/1 kV XLPE insulated, copper wire waveform concentric cables with solid aluminium conductors
Hardcopy , PDF
31-12-2011
English
04-02-2004
Committees responsible
Foreword
1 Scope
2 Normative references
3 Voltage designation
4 Core conductors
5 Insulation
6 Assembly of cores
7 Concentric conductor
8 Oversheath
9 Marking
10 End sealing
11 Dimensions
12 Tests
13 Routine tests
14 Sample tests
15 Type tests
Bibliography
Provides requirements for the construction, dimensions and mechanical and electrical properties of waveform cables with solid aluminium core conductors, XLPE insulation and PVC oversheath having a rated voltage of 0.6/1(1.2) kV.
Committee |
GEL/20/16
|
DevelopmentNote |
Supersedes BS 7870-3.4(1996) (08/2001) To be read in conjunction with BS 7870-1(1996) & BS 7870-2(1999) Supersedes 99/244661 DC & 02/209791 DC (02/2004)
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
BS 7870-3.50:2005 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire. (Implementation of HD 603) |
11/30214071 DC : 0 | BS 7870-3.50 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.50: XLPE INSULATED, COPPER WIRE WAVEFORM OR HELICAL CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
05/30126924 DC : DRAFT MAY 2005 | BS 7870-3.50 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 3: SPECIFICATION FOR DISTRIBUTION CABLES OF RATED VOLTAGE 0.6/1 KV - SECTION 3.50: XLPE INSULATED, COPPER WIRE WAVEFORM OR HELICAL CONCENTRIC CABLES WITH SOLID ALUMINIUM CONDUCTORS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
HD 622 S1:1996/A2:2005 | Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations |
HD 627 S1:1996/A2:2005 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
BS 4109:1970 | Specification for copper for electrical purposes. Wire for general electrical purposes and for insulated cables and flexible cords |
HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
BS EN 60811-1-3:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test |
HD 603 S1:1994/A3:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
HD 626 S1:1996/A2:2002 | OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV |
HD 308 S2:2001 | Identification of cores in cables and flexible cords |
BS EN 60811-1-2:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods |
HD 604 S1:1994/A3:2005 | 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.