• BS 7870-3.50:2011

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated, copper wire waveform or helical concentric cables with solid aluminium conductors, having low emission of smoke and corrosive gases when affected by fire

    Available format(s):  Hardcopy, PDF

    Superseded date:  15-12-2023

    Language(s):  English

    Published date:  31-08-2012

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Voltage designation
    4 Core conductors
    5 Insulation
    6 Assembly of cores
    7 Concentric conductor
    8 Oversheath
    9 Marking
    10 End sealing
    11 Dimensions
    12 Tests
    13 Routine tests
    14 Sample tests
    15 Type tests
    Annexes
    Annex A (informative) - Guide to selection and
            use of cables
    Annex B (normative) - Test for shrinkage of
            oversheath on cable
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines requirements for the construction, dimensions and mechanical and electrical properties of XLPE insulated, concentric copper wire screened waveform or helical cables with solid aluminium core conductors having a rated voltage of 0.6/1(1.2) kV.

    Scope - (Show below) - (Hide below)

    This section of BS 7870 specifies requirements for the construction, dimensions and mechanical and electrical properties of XLPE insulated, concentric copper wire screened waveform or helical cables with solid aluminium core conductors having a rated voltage of 0.6/1(1.2) kV. It is applicable to cables that, when assessed by the specified tests, produce lower levels of smoke and corrosive gases under exposure to fire than cables conforming to BS 7870-3.11 or to BS 7870-3.40.

    It specifies requirements for the following types of cable:

    • 3-core, 3-phase, with XLPE insulation, a concentric neutral/earth conductor of copper wires on a synthetic bedding and a thermoplastic oversheath;

    • 4-core, 3-phase and a separate neutral, with XLPE insulation, a concentric earth conductor of copper wires on a synthetic bedding, and a thermoplastic oversheath.

    This section of BS 7870 is applicable to cables that are designed for a maximum continuous conductor operating temperature of 80 °C and for a maximum short circuit conductor temperature of 250 °C.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20/16
    Development Note To be read in conjunction with BS 7870-1(2011) & BS 7870-2(2011). Supersedes BS 7870-3.50(2005) and 11/30214071 DC. (12/2011)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    HD 627 S1:1996/A2:2005 MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND
    BS EN 61034-2 : 2005 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS PART 2: TEST PROCEDURE AND REQUIREMENTS
    BS EN 61034-1 : 2005 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 1: TEST APPARATUS
    BS EN 60332-1-2 : 2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004)
    BS 7870-2:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test
    HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
    HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
    BS EN 50267-2-1:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures Determination of the amount of halogen acid gas - Determination of the amount of halogen acid gas
    BS EN 60228:2005 Conductors of insulated cables
    BS EN 60811-1-3:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test
    HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
    BS EN 60332-3-24:2009 Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category C
    HD 626 S1:1996/A2:2002 OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV
    BS EN 60811-1-2:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods
    BS 7870-3.11:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for distribution cables of rated voltage 0.6/1 kV. XLPE insulated combined neutral and earth copper wire concentric cables with copper or aluminium conductors
    BS 7870-1:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities General