BS 7870-8.4:2003
Current
The latest, up-to-date edition.
LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and PVC sheathed multipair cable with copper conductors, having reduced fire propagation performance - Section 8.4 Single wire or double steel tape armoured and PVC sheathed multipair cable with copper conductors, having reduced fire propagation performance
Hardcopy , PDF
English
16-06-2003
Foreword
1 Scope
2 Normative references
3 Voltage designation
4 Conductors
5 Insulation
6 Identification of cores
7 Assembly of cores, fillers and binders
8 Bedding layer
9 Armouring
10 Oversheath
11 Marking
12 Dimensions
13 Tests
14 Routine tests
15 Sample tests
16 Type test
Annex A (informative) Guide to use
Bibliography
Defines requirements for the construction, dimensions and mechanical and physical properties of multipair PVC insulated and PVC sheathed cables having reduced fire propagation performance.
Committee |
GEL/20/16
|
DevelopmentNote |
Supersedes 99/244662 DC To be read in conjunction with BS 7870-1(1996) and BS 7870-2(1999). (06/2003) Reviewed and confirmed by BSI, October 2008. (09/2008)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This section of BS 7870 specifies requirements for the construction, dimensions and mechanical and physical properties of multipair PVC insulated and PVC sheathed cables having reduced fire propagation performance conforming to BS EN 50265-2-1 and BS EN ISO 4589-3.
It specifies requirements for:
- multipair cables (2 pairs to 200 pairs) having copper conductors, a collective screen and armouring consisting of a single layer of steel wires;
- multipair cables (20 pairs to 200 pairs) having copper conductors, a collective screen and armouring consisting of a double layer of steel tapes.
This section of BS 7870 is applicable to cables for use in and around power stations and other installations having similar cable densities.
NOTE A “guide to use?? is given in Annex A.
Standards | Relationship |
HD 627 S1:1996/A2:2005 | Identical |
HD 622 S1:1996/A2:2005 | Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations |
HD 627 S1:1996/A2:2005 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
IEC 60189-1:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 1: General test and measuring methods |
BS EN ISO 4589-3:2017 | Plastics. Determination of burning behaviour by oxygen index Elevated-temperature test |
HD 605 S2:2008/corrigendum:2010 | ELECTRIC CABLES - ADDITIONAL TEST METHODS |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
BS EN 60811-1-1:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties |
HD 603 S1:1994/A3:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
BS EN 60811-3-1:1995 | Insulating and sheathing materials of electric cables. Common test methods. Methods specific to PVC compounds Pressure test at high temperature. Tests for resistance to cracking |
HD 626 S1:1996/A2:2002 | OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV |
BS EN 50265-2-1:1999 | Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable. Procedures 1 kW pre-mixed flame - 1 kW pre-mixed flame |
IEC 60189-2:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 2: Cables in pairs, triples, quads and quintuples for inside installations |
BS EN 60811-1-4:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Tests at low temperature |
BS EN 60811-3-2:1995 | Insulating and sheathing materials of electric cables. Common test methods Methods specific to PVC compounds - Loss of mass test. Thermal stability test |
HD 604 S1:1994/A3:2005 | 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.