• BS 7870-8.4:2003

    Current The latest, up-to-date edition.

    LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire or double steel tape armoured and PVC sheathed multipair cable with copper conductors, having reduced fire propagation performance - Section 8.4 Single wire or double steel tape armoured and PVC sheathed multipair cable with copper conductors, having reduced fire propagation performance

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  16-06-2003

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Voltage designation
    4 Conductors
    5 Insulation
    6 Identification of cores
    7 Assembly of cores, fillers and binders
    8 Bedding layer
    9 Armouring
    10 Oversheath
    11 Marking
    12 Dimensions
    13 Tests
    14 Routine tests
    15 Sample tests
    16 Type test
    Annex A (informative) Guide to use
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines requirements for the construction, dimensions and mechanical and physical properties of multipair PVC insulated and PVC sheathed cables having reduced fire propagation performance.

    Scope - (Show below) - (Hide below)

    This section of BS 7870 specifies requirements for the construction, dimensions and mechanical and physical properties of multipair PVC insulated and PVC sheathed cables having reduced fire propagation performance conforming to BS EN 50265-2-1 and BS EN ISO 4589-3.

    It specifies requirements for:

    1. multipair cables (2 pairs to 200 pairs) having copper conductors, a collective screen and armouring consisting of a single layer of steel wires;
    2. multipair cables (20 pairs to 200 pairs) having copper conductors, a collective screen and armouring consisting of a double layer of steel tapes.

    This section of BS 7870 is applicable to cables for use in and around power stations and other installations having similar cable densities.

    NOTE A “guide to use?? is given in Annex A.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20/16
    Development Note Supersedes 99/244662 DC To be read in conjunction with BS 7870-1(1996) and BS 7870-2(1999). (06/2003) Reviewed and confirmed by BSI, October 2008. (09/2008)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    HD 622 S1:1996/A2:2005 Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations
    HD 627 S1:1996/A2:2005 MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND
    IEC 60189-1:2007 Low-frequency cables and wires with PVC insulation and PVC sheath - Part 1: General test and measuring methods
    BS EN ISO 4589-3:2017 Plastics. Determination of burning behaviour by oxygen index Elevated-temperature test
    HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
    HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
    BS EN 60811-1-1:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
    HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
    BS EN 60811-3-1:1995 Insulating and sheathing materials of electric cables. Common test methods. Methods specific to PVC compounds Pressure test at high temperature. Tests for resistance to cracking
    HD 626 S1:1996/A2:2002 OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV
    BS EN 50265-2-1:1999 Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable. Procedures 1 kW pre-mixed flame - 1 kW pre-mixed flame
    IEC 60189-2:2007 Low-frequency cables and wires with PVC insulation and PVC sheath - Part 2: Cables in pairs, triples, quads and quintuples for inside installations
    BS EN 60811-1-4:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Tests at low temperature
    BS EN 60811-3-2:1995 Insulating and sheathing materials of electric cables. Common test methods Methods specific to PVC compounds - Loss of mass test. Thermal stability test
    HD 604 S1:1994/A3:2005 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective