BS 7888-3:1998
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
LV and MV accessories for power cables with rated voltage from 0.6/1 kV (Um=1.2 kV) up to and including 20.8/36 kV (Um=42 kV) Test requirements for LV accessories
Hardcopy , PDF
31-08-2006
English
02-05-2003
Committees responsible
Foreword
1 Scope
2 References
3 Definitions
4 Operating conditions
5 Requirements
6 Type testing
Tables
1 Maximum rated conductor temperatures
2 Summary of approvals for different cable insulations
3 Test sequence for joints for extruded insulation cables,
transition joints between extruded insulation cables and
impregnated paper insulated cables
4 Test sequence for stop ends on extruded insulation cables
5 Test sequence for outdoor terminations on extruded
insulation cables
6 Number of test samples and conductor size
List of references
Specifies performance requirements for joints, stop ends and outdoor terminations for LV cables to BS 7870-3. Accessories for special applications, such as submarine or ships cables or hazardous situations are not included.
Committee |
GEL/20/11
|
DevelopmentNote |
To be read in conjunction with BS 7888-1(1998) and BS 7888-2(1998) Supersedes 00/244006 DC and 92/26317 DC (05/2003)
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
HD 623 : S1 AMD 11 2001 | Similar to |
BS 7888-2:1998 | LV and MV accessories for power cables with rated voltage from 0.6/1 kV (<i>U</i><sub>m</sub>=1.2 kV) up to and including 20.8/36 kV (<i>U</i><sub>m</sub>=42 kV) Methods of test |
HD 629.2 S2:2006/A1:2008 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
BS 7888-1:1998 | LV and MV accessories for power cables with rated voltage from 0.6/1 kV (<i>U</i><sub>m</sub>=1.2 kV) up to and including 20.8/36 kV (<i>U</i><sub>m</sub>=42 kV) General |
HD 628 : 200S1 | TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 3.6/6 KV (UM = 7.2 KV) UP TO AND INCLUDING 20.8/36 KV (UM = 42 KV) |
BS 7888-2:1998 | LV and MV accessories for power cables with rated voltage from 0.6/1 kV (<i>U</i><sub>m</sub>=1.2 kV) up to and including 20.8/36 kV (<i>U</i><sub>m</sub>=42 kV) Methods of test |
BS 7933-1:1998 | Electric cables. Accessories. Material characterization Resinous compounds before cure and in the cured state |
HD 629.1 S2:2006/A1:2008 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.