• HD 629.2 S2:2006/A1:2008

    Current The latest, up-to-date edition.

    TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION

    Available format(s): 

    Language(s): 

    Published date:  10-09-2008

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Definitions
    4 Components
    5 Test assemblies
    6 Range of compliance
    7 Test sequences
    8 Test results
    Annex A (informative) - Identification of test
            cable (paper insulated)
    Annex B (informative) - Identification of test
            cable (extruded insulation)

    Abstract - (Show below) - (Hide below)

    Provides performance requirements for cable accessories for use on impregnated paper insulated power cables as specified in HD 621.

    General Product Information - (Show below) - (Hide below)

    Committee TC 20
    Development Note Also numbered as BS 7888-4.2(2006). (03/2006) Supersedes UNE HD 629-2. (09/2008)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 50655-3:2017 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 3: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV
    BS 7888-2:1998 LV AND MV ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGE FROM 0.6/1 KV (U[M] = 1.2 KV) UP TO AND INCLUDING 20.8/36 KV (U[M] = 42 KV) - PART 2: METHODS OF TEST
    NF EN 60684-3-282 : 2010 FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 282: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, STRESS CONTROL
    BS EN 50655-2:2017 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 2: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV
    ENA ER G81-5 : ISSUE 2 2016 FRAMEWORK FOR NEW INDUSTRIAL AND COMMERCIAL UNDERGROUND CONNECTIONS - PART 5: MATERIALS SPECIFICATION
    EN 50655-3:2017 Electric cables - Accessories - Material characterization - Part 3: Fingerprinting for cold shrinkable components for low and medium voltage applications up to 20,8/36 (42) kV
    PREN 50655-2 : DRAFT 2015 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 2: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV
    HD 631.4 S1:2008 Electrical cables - Accessories - Material characterisation - Part 4: Fingerprinting for cold shrinkable components for low and medium voltage applications up to 20,8/36 (42) kV
    EN 60455-3-8:2013 Resin based reactive compounds used for electrical insulation - Part 3: Specifications for individual materials - Sheet 8: Resins for cable accessories
    I.S. EN 50655-1:2017 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 1: FINGERPRINTING FOR RESINOUS COMPOUNDS
    EN 50655-1:2017 Electric cables - Accessories - Material characterization - Part 1: Fingerprinting for resinous compounds
    I.S. EN 45510-2-9:2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
    PREN 50655-3 : DRAFT 2015 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 3: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV
    NF EN 60684-3-281 : 2010 FLEXIBLE INSULATING SLEEVING - PART 3: SPECIFICATION FOR INDIVIDUAL TYPES OF SLEEVING - SHEET 281: HEAT-SHRINKABLE, POLYOLEFIN SLEEVING, SEMICONDUCTIVE
    PREN 50655-1 : DRAFT 2015 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 1: FINGERPRINTING FOR RESINOUS COMPOUNDS
    17/30365113 DC : 0 BS EN 60455-3-8 ED.2.0 - RESIN BASED REACTIVE COMPOUNDS USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 8: RESINS FOR CABLE ACCESSORIES
    CEI EN 60455-3-8 : 2014 RESIN BASED REACTIVE COMPOUNDS USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 8: RESINS FOR CABLE ACCESSORIES
    I.S. EN 50655-2:2017 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 2: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV
    CEI 20-94 : 2010 ELECTRICAL CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 4: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV
    BS 7933-1:2007 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 1: FINGERPRINTING AND TYPE TESTS FOR RESINOUS COMPOUNDS
    15/30325650 DC : 0 BS EN 50655-1 - ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 1: FINGERPRINTING FOR RESINOUS COMPOUNDS
    HD 631.3 : 2008 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 3: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR MEDIUM VOLTAGE APPLICATIONS FROM 3,6/6 (7,2) KV UP TO 20,8/36 (42) KV
    BS EN 60455-3-8:2013 RESIN BASED REACTIVE COMPOUNDS USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 8: RESINS FOR CABLE ACCESSORIES
    15/30325653 DC : 0 BS EN 50655-2 - ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 2: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV
    BS 7933-1:1998 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - RESINOUS COMPOUNDS BEFORE CURE AND IN THE CURED STATE
    NFC 33 009-1 : 2008 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 1: FINGERPRINTING AND TYPE TESTS FOR RESINOUS COMPOUNDS
    BS 7888-4.2:1998 LV AND MV ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGE FROM 0.6/1 KV (U[M] = 1.2 KV) UP TO AND INCLUDING 20.8/36 KV (U[M] = 42 KV) - PART 4: TEST REQUIREMENTS FOR MV ACCESSORIES - SECTION 4.2: ACCESSORIES FOR CABLES WITH IMPREGNATED PAPER INSULATION
    EN 50655-2:2017 Electric cables - Accessories - Material characterization - Part 2: Fingerprinting for heat shrinkable components for low and medium voltage applications up to 20,8/36 (42) kV
    HD 631.1 : 200S2 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 1: FINGERPRINTING AND TYPE TESTS FOR RESINOUS COMPOUNDS
    I.S. HD 631.4:2008 ELECTRICAL CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 4: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV
    EN 45510-2-9:2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
    BS 7888-3:1998 LV AND MV ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGE FROM 0.6/1 KV (U[M] = 1.2 KV) UP TO AND INCLUDING 20.8/36 KV (U[M] = 42 KV) - PART 3: TEST REQUIREMENTS FOR LV ACCESSORIES
    BS 7888-1:1998 LV AND MV ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGE FROM 0.6/1 KV (U[M] = 1.2 KV) UP TO AND INCLUDING 20.8/36 KV (U[M] = 42 KV) - PART 1: GENERAL
    05/30134209 DC : DRAFT MAY 2005 HD 631.4 S1 ED. 1 - ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 4: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36(42) KV
    I.S. EN 60455-3-8:2013 RESIN BASED REACTIVE COMPOUNDS USED FOR ELECTRICAL INSULATION - PART 3: SPECIFICATIONS FOR INDIVIDUAL MATERIALS - SHEET 8: RESINS FOR CABLE ACCESSORIES (IEC 60455-3-8:2013 (EQV))
    BS 7933-4(2008) : 2008 ELECTRICAL CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 4: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV
    BS EN 50655-1:2017 Electric cables. Accessories. Material characterization Fingerprinting for resinous compounds
    CEI 20-93 : 2010 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 3: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR MEDIUM VOLTAGE APPLICATIONS FROM 3,6/6 (7,2) KV UP TO 20,8/36 (42) KV
    IEC 60455-3-8:2013 Resin based reactive compounds used for electrical insulation - Part 3: Specifications for individual materials - Sheet 8: Resins for cable accessories
    EN 45510-2-9 : 2008 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS
    05/30134174 DC : DRAFT MAY 2005 HD 631.3 S1 ED. 1 - ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 3: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR MEDIUM VOLTAGE APPLICATIONS FROM 3,6/6 (7,2) KV UP TO 20,8/36 (42) KV
    15/30325656 DC : 0 BS EN 50655-3 - ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 3: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV
    I.S. EN 50655-3:2017 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 3: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36 (42) KV
    NFC 33 009-3 : 2008 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 3: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR MEDIUM VOLTAGE APPLICATIONS FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV
    BS 7933-3(2008) : 2008 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 3: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR MEDIUM VOLTAGE APPLICATIONS FROM 3,6/6 (7,2) KV UP TO 20,8/36 (42) KV
    CEI 20-79 : 2009 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 1: FINGERPRINTING AND TYPE TESTS FOR RESINOUS COMPOUNDS
    NFC 33 009-4 : 2008 ELECTRICAL CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 4: FINGERPRINTING FOR COLD SHRINKABLE COMPONENTS FOR LOW AND MEDIUM VOLTAGE APPLICATIONS UP TO 20,8/36(42) KV
    I.S. HD 631.3:2008 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 3: FINGERPRINTING FOR HEAT SHRINKABLE COMPONENTS FOR MEDIUM VOLTAGE APPLICATIONS FROM 3,6/6 (7,2) KV UP TO 20,8/36 (42) KV
    BS EN 45510-2-9:2008 Guide for procurement of power station equipment Electrical equipment. Cabling systems

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 61238-1:2003 Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV) - Part 1: Test methods and requirements
    IEC 61442:2005 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
    BS 7870-4.13:2001 LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.13: SINGLE CORE 33 KV COPPER WIRE/FOIL SHEATH CABLES
    HD 631.1 : 200S2 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 1: FINGERPRINTING AND TYPE TESTS FOR RESINOUS COMPOUNDS
    BS 7933-1:2007 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 1: FINGERPRINTING AND TYPE TESTS FOR RESINOUS COMPOUNDS
    BS 7894:2003 MV IMPREGNATED PAPER INSULATED DISTRIBUTION CABLES OF RATED VOLTAGES OF 3.8/6.6 KV TO 19/33 KV
    HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
    BS 7870-4.10(2011) : 2011 LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION OF RATED VOLTAGES OF 11 KV TO 33 KV - SECTION 4.10: SINGLE-CORE 11 KV TO 33 KV CABLES (IMPLEMENTATION OF HD 620)
    HD 428.2.2 : 200S1 THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 2: DISTRIBUTION TRANSFORMERS WITH CABLE BOXES ON THE HIGH-VOLTAGE AND/OR LOW VOLTAGE SIDE - SECTION 2: CABLE BOXES TYPE 1 FOR USE ON DISTRIBUTION TRANSFORMERS MEETING THE REQUIREMENTS OF HD 428.2.1 S1
    BS 7821-2.2:1998 THREE PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS, 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - DISTRIBUTION TRANSFORMERS WITH CABLE BOXES ON THE HIGH VOLTAGE AND/OR LOW VOLTAGE SIDE - CABLE BOXES OF TYPE 1 FOR USE ON DISTRIBUTION TRANSFORMERS MEETING THE REQUIREMENTS OF BS 7821-2.1
    EN 50180:2010 Bushings above 1 kV up to 52 kV and from 250 A to 3,15 kA for liquid filled transformers – Part 1: General requirements for bushings
    IEC 61238-1:2003 Compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV) - Part 1: Test methods and requirements
    EN 61442:2005 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV)
    IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
    EN 50181:2010 Plug-in type bushings above 1 kV up to 52 kV and from 250 A to 2,50 kA for equipment other than liquid filled transformers
    HD 629.1 S2:2006/A1:2008 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION
    HD 621 S1:1996/A1:2001 MV IMPREGNATED PAPER INSULATED DISTRIBUTION CABLES OF RATED VOLTAGES OF 3.8/6.6 KV TO 19/33 KV
    BS 7870-4.12:2001 LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 4: SPECIFICATION FOR DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES OF 11 KV AND 33 KV - SECTION 4.12: SINGLE CORE 11 KV COPPER FOIL SHEATH CABLES
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective