BS 7912(2012) : 2012
Current
The latest, up-to-date edition.
POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV)
Hardcopy , PDF
English
01-01-2012
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Voltage designation and cable design features
5 Marking of cables
6 Cable characteristics
7 Accessory characteristics
8 Test conditions
9 Routine tests on cables and on the main insulation
of prefabricated accessories
10 Sample tests
11 Type tests - Summary
12 Electrical type tests on cables
13 Type tests on cable components
14 Longitudinal water penetration type test on complete
cables
15 Mechanical and thermal type tests on complete cables
16 Type tests on accessories
17 Type tests on ancillary equipment
18 Electrical tests after installation
Annex A (normative) - Tests and requirements for cable
bonding leads
Annex B (normative) - Tests and requirements for sheath
voltage limiters (SVLs)
Annex C (normative) - Tests and requirements for link
housings
Annex D (normative) - Additional water blocking test for
phase conductor
Bibliography
Defines tests and requirements for power cables with XLPE insulation and metal sheath and their accessories for rated voltages from 66 kV (U[m] = 72.5 kV) to 132 kV (U[m] = 145 kV) for fixed installations.
Committee |
GEL/20/16
|
DevelopmentNote |
Supersedes BS 7912(2001) & 12/30244367 DC. (12/2012) Supersedes 17/30354015 DC. 2012 Edition Re-issued in July 2017 & incorporates AMD 1 2017. (07/2017)
|
DocumentType |
Standard
|
Pages |
66
|
PublisherName |
British Standards Institution
|
Status |
Current
|
HD 632 S1:1998 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
BS EN 60811-509:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Test for resistance of insulations and sheaths to cracking (heat shock test) |
BS EN 60811-401:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Miscellaneous tests. Thermal ageing methods. Ageing in an air oven |
BS EN 60229:2008 | Electric cables. Tests on extruded oversheaths with a special protective function |
BS EN 60811-605:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Physical tests. Measurement of carbon black and/or mineral filler in polyethylene compounds |
BS EN 60811-502:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Shrinkage test for insulations |
BS EN 60332-1-2 : 2004 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004) |
BS 7870-2:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test |
BS EN 60811-201:2012 | Electric and optical fibre cables. Test methods for non-metallic materials General tests. Measurement of insulation thickness |
BS EN 61462:2007 | Composite hollow insulators. Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1000 V. Definitions, test methods, acceptance criteria and design recommendations |
BS EN 60811-507:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Hot set test for cross-linked materials |
BS EN 62271-209:2007 | High-voltage switchgear and controlgear Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV. Fluid-filled and extruded insulation cables. Fluid-filled and dry-type cable-terminations |
BS EN 60228:2005 | Conductors of insulated cables |
BS 7970:2005 | Electric cables. Metallic wire and foil sheath constructions of power cables having XLPE insulation for rated voltages from 66kV (U<sub>m</sub> = 72.5 kV) to 132kV (U<sub>m</sub> = 145 kV) |
BS EN 60811-501 : 2012 | ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 501: MECHANICAL TESTS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES OF INSULATING AND SHEATHING COMPOUNDS |
BS EN 60885-3:2015 | Electrical test methods for electric cables Test methods for partial discharge measurements on lengths of extruded power cables |
BS EN 60811-409:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Miscellaneous tests. Loss of mass test for thermoplastic insulations and sheaths |
BS EN 60811-505:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Elongation at low temperature for insulations and sheaths |
IEC 60183:2015 | Guidance for the selection of high-voltage A.C. cable systems |
BS EN 60811-503:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Shrinkage test for sheaths |
BS EN 60230:2002 | Impulse tests on cables and their accessories |
BS EN 60060-1:2010 | High-voltage test techniques General definitions and test requirements |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
BS EN 60811-508:2012 | Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Pressure test at high temperature for insulation and sheaths |
BS EN 60811-202:2012 | Electric and optical fibre cables. Test methods for non-metallic materials General tests. Measurement of thickness of non-metallic sheath |
BS EN 60099-4:2014 | Surge arresters Metal-oxide surge arresters without gaps for a.c. systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.