• BS 7970:2012

    Current The latest, up-to-date edition.

    Electric cables. Metal foil and longitudinally welded aluminium sheath constructions of power cables having XLPE insulation for rated voltages from 66 kV (Um = 72.5 kV) to 132 kV (Um = 145 kV)

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  31-12-2012

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Construction of metal wire and foil sheaths
    5 Marking of cables
    6 Routine tests on cables
    7 Sample tests on cables
    8 Type tests on cables and components
    Annexes
    Annex A (normative) - Die penetrant test for weld
            integrity
    Annex B (normative) - Test for peel strength of
            overlapped metal foil
    Annex C (normative) - Test for adhesion strength
            of metal foil
    Annex D (normative) - Test for impact
    Annex E (normative) - Test for sidewall loading
    Annex F (normative) - Test for corrosion
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes requirements for construction and performance, and gives methods of test, for metal wire and foil sheath, or metal wire and longitudinally welded aluminium, or longitudinally welded aluminium constructions of power cables having XLPE insulation for rated voltages from 66 kV (U[m] = 72.5 kV) to 132 kV (U[m] = 145 kV).

    Scope - (Show below) - (Hide below)

    This British Standard specifies requirements for construction and performance, and gives methods of test, for metal wire and foil sheath, or metal wire and longitudinally welded aluminium, or longitudinally welded aluminium constructions of power cables having XLPE insulation for rated voltages from 66 kV (Um = 72.5 kV) to 132 kV (Um = 145 kV). The tests and requirements in this British Standard are additional to the tests and requirements for cables and their accessories specified in BS 7912.

    NOTE 1 In exceptional cases, with very low fault currents, foil sheath designs without metal wires may also be used.

    NOTE 2 Tests described in BS 7912:2012, 15.2, 15.3 and 15.4 are not required in this standard.

    This British Standard is applicable to single-core cables for usual conditions of installation and operation, but not to special cables, such as those designed for submarine applications.

    NOTE 3 Annex A gives requirements for a die penetrant test for weld integrity. Annex B lists a test for peel strength of overlapped metal foil. Annex C lists test requirements for adhesion strength of metal foil. Annex D covers the test for impact and Annex E the test for sidewall loading. Annex F covers the test for corrosion.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20/16
    Development Note Supersedes BS 7970(2005) & 12/30244364 DC. (12/2012)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    HD 632 : 1998 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
    BS 7870-2:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test
    BS EN 60228:2005 Conductors of insulated cables
    IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective