BS 8512:2008

Current

Current

The latest, up-to-date edition.

Electric cables. Code of practice for the storage, handling, installation and disposal of cables on wooden drums

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-03-2008

€165.94
Excluding VAT

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Personal protective equipment
5 Storage
6 Manual handling
7 Lifting
8 Unwinding and rewinding
9 Storage and handling at the installation site
10 Installation
11 Disposal
Bibliography

Provides recommendations for the storage and handling of cables for fixed installations, rated up to 1900/3300 V, that are packaged on wooden cable drums suitable for storage outdoors.

Committee
GEL/20/17
DevelopmentNote
Supersedes 07/30169968 DC. (03/2008)
DocumentType
Standard
Pages
16
PublisherName
British Standards Institution
Status
Current
Supersedes

This British Standard gives recommendations for the storage and handling of cables for fixed installations, rated up to 1 900/3 300 V, that are packaged on wooden cable drums suitable for storage outdoors.

NOTE The recommendations could also be applied to:

  • cables of higher rated voltages that are packaged on wooden drums; and
  • cables of similar size, on similar wooden drums, and made to standards and specifications not specifically quoted here.

This standard does not cover metal drums, cable spools or cable reels, or trailing and reeling cables.

BS 7889:2012 Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000 V, for fixed installations
11/30214055 DC : 0 BS 7870-1 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 1: GENERAL
12/30244462 DC : 0 BS 8573 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS, HAVING LOW EMISSIONS OF SMOKE AND CORROSIVE WHEN AFFECTED BY FIRE
BS 7870-1:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities General
BS 7846:2015 Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification
BS 7846:2009 Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000 V, having low emission of smoke and corrosive gases when affected by fire. Specification
BS PAS 5308-1(2009) : 2009 CONTROL AND INSTRUMENTATION CABLES - PART 1: SPECIFICATION FOR POLYETHYLENE INSULATED CABLES
15/30301501 DC : 0 BS 5467 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, FOR FIXED INSTALLATIONS - SPECIFICATION
BS 6724:2016 Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification
15/30301742 DC : 0 BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS
BS PAS 5308-2(2009) : 2009 CONTROL AND INSTRUMENTATION CABLES - PART 2: SPECIFICATION FOR PVC INSULATED CABLES
BS 5467:2016 Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations. Specification
09/30199575 DC : 0 BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION
15/30301443 DC : 0 BS 6724 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1 900/3300 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION
BS 8573:2012 Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire
12/30244369 DC : 0 BS 7889 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS

BS 6004:2000 Electric cables. PVC insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring
BS 7211:1998 Electric cables. Thermosetting insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring, and having low emission of smoke and corrosive gases when affected by fire
BS 6346:1997 Electric cables. PVC insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
BS 8436:2004 Electric cables. 300/500 V screened electric cables having low emission of smoke and corrosive gases when affected by fire, for use in walls, partitions and building voids. Multicore cables
BS 7919:2001 Electric cables. Flexible cables rated up to 450/750V, for use with appliances and equipment intended for industrial and similar environments

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.