BS 8512:2008
Current
The latest, up-to-date edition.
Electric cables. Code of practice for the storage, handling, installation and disposal of cables on wooden drums
Hardcopy , PDF
English
31-03-2008
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Personal protective equipment
5 Storage
6 Manual handling
7 Lifting
8 Unwinding and rewinding
9 Storage and handling at the installation site
10 Installation
11 Disposal
Bibliography
Provides recommendations for the storage and handling of cables for fixed installations, rated up to 1900/3300 V, that are packaged on wooden cable drums suitable for storage outdoors.
Committee |
GEL/20/17
|
DevelopmentNote |
Supersedes 07/30169968 DC. (03/2008)
|
DocumentType |
Standard
|
Pages |
16
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This British Standard gives recommendations for the storage and handling of cables for fixed installations, rated up to 1 900/3 300 V, that are packaged on wooden cable drums suitable for storage outdoors.
NOTE The recommendations could also be applied to:
- cables of higher rated voltages that are packaged on wooden drums; and
- cables of similar size, on similar wooden drums, and made to standards and specifications not specifically quoted here.
This standard does not cover metal drums, cable spools or cable reels, or trailing and reeling cables.
BS 7889:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000 V, for fixed installations |
11/30214055 DC : 0 | BS 7870-1 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 1: GENERAL |
12/30244462 DC : 0 | BS 8573 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS, HAVING LOW EMISSIONS OF SMOKE AND CORROSIVE WHEN AFFECTED BY FIRE |
BS 7870-1:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities General |
BS 7846:2015 | Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS 7846:2009 | Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000 V, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS PAS 5308-1(2009) : 2009 | CONTROL AND INSTRUMENTATION CABLES - PART 1: SPECIFICATION FOR POLYETHYLENE INSULATED CABLES |
15/30301501 DC : 0 | BS 5467 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, FOR FIXED INSTALLATIONS - SPECIFICATION |
BS 6724:2016 | Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
15/30301742 DC : 0 | BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS |
BS PAS 5308-2(2009) : 2009 | CONTROL AND INSTRUMENTATION CABLES - PART 2: SPECIFICATION FOR PVC INSULATED CABLES |
BS 5467:2016 | Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations. Specification |
09/30199575 DC : 0 | BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION |
15/30301443 DC : 0 | BS 6724 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1 900/3300 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION |
BS 8573:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire |
12/30244369 DC : 0 | BS 7889 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS |
BS 6004:2000 | Electric cables. PVC insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring |
BS 7211:1998 | Electric cables. Thermosetting insulated, non-armoured cables for voltages up to and including 450/750 V, for electric power, lighting and internal wiring, and having low emission of smoke and corrosive gases when affected by fire |
BS 6346:1997 | Electric cables. PVC insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
BS 8436:2004 | Electric cables. 300/500 V screened electric cables having low emission of smoke and corrosive gases when affected by fire, for use in walls, partitions and building voids. Multicore cables |
BS 7919:2001 | Electric cables. Flexible cables rated up to 450/750V, for use with appliances and equipment intended for industrial and similar environments |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.