BS 8552:2012
Current
The latest, up-to-date edition.
Sampling and monitoring of water from building services closed systems. Code of practice
Hardcopy , PDF
English
30-11-2012
Foreword
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Design of the sampling programme
5 Sample locations and frequency
6 Sampling methodology
7 Documentation and reporting of results
8 Interpretation of results
Annexes
Annex A (normative) - Sampling points
Annex B (normative) - Laboratory analytical methods for
water quality sampling
Annex C (informative)- Method for detecting sulfate reducing
bacteria (SRBs)
Annex D (informative) - Minimum performance requirements
for on-site analysis
Annex E (normative) - Interpretation of results for
pre-commission cleaning
Bibliography
Specifies recommendations for the design of the sampling programme during each phase of the system lifecycle, including the location and suitability of sampling points, frequency of sampling and record keeping, to facilitate the control of closed system water quality throughout the life of the building.
Committee |
EH/3/6
|
DevelopmentNote |
Supersedes 12/30215289 DC. (12/2012)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This British Standard gives recommendations and guidance for the sampling of water from closed-circuit heating and cooling systems in buildings and related infrastructure to maintain water quality and the integrity of pipework, plant and fittings, including: hydronic space heating and cooling systems; heat pump ground and water loops; thermal storage systems; closed-circuit condenser water systems; low-temperature district heating and cooling mains; generator cooling systems; and similar closed-circuit water systems. The standard gives recommendations for the design of the sampling programme during each phase of the system lifecycle, including the location and suitability of sampling points, frequency of sampling and record keeping, to facilitate the control of closed system water quality throughout the life of the building. It also gives guidance on: procedures for the collection, preservation, handling and storage of samples prior to analysis (by reference to BSENISO5667‑3); analytical methods (by reference to other British Standards and approved methods) and the statistical treatment of results; and the selection of the analytical parameters appropriate to the sampled system and life stage. This standard does not provide guidance on the interpretation of results or associated action levels. These matters are discussed in other standards and industry guides, e.g. BSRIA BG29. This standard is not applicable to sampling water from open circuit systems such as: cold water services (see BS7592 and BSISO5667‑5); open circuit cooling towers and cooling ponds; steam boiler plant (see BS6068‑6.7 and BS2486); or sprinkler systems. NOTE AnnexA gives recommendations for sampling points. AnnexB gives guidance and recommendations for appropriate laboratory analytical methods for water quality sampling, while AnnexC describes the application of a statistical method for detecting sulfate reducing bacteria (SRBs). AnnexD summarizes the minimum performance requirements for on-site analysis of common parameters using test kits and portable instruments. Guidance on the interpretation of sample results for pre-commission cleaning with respect to the guidelines in BSRIA BG29 is given in AnnexE.
BS EN ISO 10304-1:2009 | Water quality. Determination of dissolved anions by liquid chromatography of ions Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate |
BS EN ISO 16264:2004 | Water quality. Determination of soluble silicates by flow analysis (FIA and CFA) and photometric detection |
BS EN 15216:2007 | Characterization of waste. Determination of total dissolved solids (TDS) in water and eluates |
BS EN ISO 11885:2009 | Water quality. Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES) |
BS 6068-2.11:1984 | Water quality. Physical, chemical and biochemical methods Determination of ammonium: manual spectrometric method |
BS 7592:2008 | Sampling for Legionella bacteria in water systems. Code of practice |
BS 6068-2.34:1988 | Water quality. Physical, chemical and biochemical methods Method for the determination of the chemical oxygen demand |
BS EN 27888:1993 | Water quality. Method for the determination of electrical conductivity |
BS EN 872:2005 | Water quality. Determination of suspended solids. Method by filtration through glass fibre filters |
BS EN ISO 19458:2006 | Water quality. Sampling for microbiological analysis |
BS ISO 17381:2003 | Water quality. Selection and application of ready-to-use test kit methods in water analysis |
ISO 5667-7:1993 | Water quality Sampling Part 7: Guidance on sampling of water and steam in boiler plants |
BS ISO 10523 : 2008 | WATER QUALITY - DETERMINATION OF PH |
BS EN ISO 13720:2010 | Meat and meat products. Enumeration of presumptive Pseudomonas spp. |
BS EN ISO 9963-1:1996 | Water quality. Determination of alkalinity Determination of total and composite alkalinity |
BS ISO 5667-5:2006 | Water quality. Sampling Guidance on sampling of drinking water from treatment works and piped distribution systems |
BS EN ISO 6222:1999 | Water quality. Enumeration of culturable micro-organisms. Colony count by inoculation in a nutrient agar culture medium |
NACE TM 01 94 : 2014 | FIELD MONITORING OF BACTERIAL GROWTH IN OIL AND GAS SYSTEMS |
BS 6068-6.7:1994 | Water quality. Sampling Guidance on sampling of water and steam in boiler plants |
BS EN ISO 5667-3:2012 | Water quality. Sampling Preservation and handling of water samples |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.