BS 9990:2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Code of practice for non-automatic fire-fighting systems in buildings
Hardcopy , PDF
31-01-2015
English
31-05-2006
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Fire mains
4.1 Design considerations
4.2 Provision and siting
4.3 Electrical earthing
5 Private fire hydrants
5.1 Design considerations
5.2 Provision and siting
6 Water supplies and pumping arrangements
6.1 Means of supply
6.2 Adequacy of basic supply
6.3 Supplementing the basic supply for wet fire mains
6.4 Pumps for wet fire mains
6.5 Additional precautions for wet fire mains
6.6 Emergency arrangements for filling suction tanks
6.7 Ring main supply
7 Installation, commissioning and maintenance
7.1 Work on site
7.2 Protection of buildings under construction
7.3 Initial inspections and acceptance tests
7.4 Maintenance of systems and rectification of defects
8 Signage
8.1 Identification of equipment
8.2 System information
Annexes
Annex A (normative) Protecting installed equipment from theft and
vandalism
Bibliography
This British Standard gives recommendations for non-automatic fire-fighting systems in buildings. It covers good practice in matters affecting the design, installation, testing and maintenance of such systems including wet and dry fire-fighting mains. It does not cover hose reels, foam inlets, automatic foam systems and portable fire-fighting equipment. These systems are covered in BS EN 671-1, BS 5306-1, BS 5306-3, BS 5306-8 and BS EN 3-7.
Committee |
FSH/14
|
DevelopmentNote |
Supersedes 05/30133584 DC and BS 5306-1(1976). (05/2006) Reviewed and confirmed by BSI, December 2011. (11/2011)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
BS 5908-2:2012 | Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations |
PD 7974-5:2014 | Application of fire safety engineering principles to the design of buildings Fire and rescue service intervention (Sub-system 5) |
BS 5306-0:2011 | Fire protection installations and equipment on premises Guide for selection of installed systems and other fire equipment |
BS 9991:2011 | Fire safety in the design, management and use of residential buildings. Code of practice |
BS 9999:2008 | Code of practice for fire safety in the design, management and use of buildings |
BS 750:2006 | Specification for underground fire hydrants and surface box frames and covers |
BS 5306-1:2006 | Code of practice for fire extinguishing installations and equipment on premises Hose reels and foam inlets |
PD 5454:2012 | Guide for the storage and exhibition of archival materials |
BS 8519:2010 | Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. Code of practice |
BS 7629-1:1997 | Specification for 300/500 V fire resistant electric cables having low emission of smoke and corrosive gases when affected by fire Multicore cables |
BS 1710:1984 | Specification for identification of pipelines and services |
BS EN 14339:2005 | Underground fire hydrants |
BS 5588-12:2004 | Fire precautions in the design, construction and use of buildings Managing fire safety |
BS EN 671-1:2012 | Fixed firefighting systems. Hose systems Hose reels with semi-rigid hose |
BS EN 14384:2005 | Pillar fire hydrants |
BS 8434-2(2003) : 2003 | METHODS OF TEST FOR ASSESSMENT OF THE FIRE INTEGRITY OF ELECTRIC CABLES - PART 2: TEST FOR UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS - BS EN 50200 WITH A 930 DEGREE C FLAME AND WITH WATER SPRAY |
BS 5499-5:2002 | Graphical symbols and signs. Safety signs, including fire safety signs Signs with specific safety meanings |
BS EN 806-2:2005 | Specifications for installations inside buildings conveying water for human consumption Design |
BS EN 3-7 : 2004 | PORTABLE FIRE EXTINGUISHERS - PART 7: CHARACTERISTICS, PERFORMANCE REQUIREMENTS AND TEST METHODS |
BS 7671(2001) : 2001 AMD 14905 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS |
BS 5588-5:2004 | Fire precautions in the design, construction and use of buildings Access and facilities for fire-fighting |
BS 5306-1:1976 | Fire extinguishing installations and equipment on premises Hydrant systems, hose reels and foam inlets |
BS 7346-6:2005 | Components for smoke and heat control systems Specifications for cable systems |
BS EN 60702-1 : 2002 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES |
BS 5306-3:2003 | Fire extinguishing installations and equipment on premises Code of practice for the inspection and maintenance of portable fire extinguishers |