BS 9991:2015
Current
The latest, up-to-date edition.
Fire safety in the design, management and use of residential buildings. Code of practice
Hardcopy , PDF
English
30-11-2016
Foreword
Section 1: General
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General recommendations
Section 2: Designing means of escape
5 General
6 Means of escape and provision for rescue from
houses
7 Means of escape from flats and maisonettes
8 Means of escape from specialized housing
9 Internal planning of flats and maisonettes
Section 3: Active fire protection
10 Fire detection and fire alarm systems
11 Automatic fire suppression systems
12 Manual fire-fighting equipment
13 Special risk protection
14 Smoke control
15 Power supplies, cabling and installation
Section 4: Design for construction
16 Fire resistance
17 Compartmentation
18 External fire spread and building separation
19 Concealed spaces
20 Materials
21 Service ducts, pipes and shafts
22 Glazed fire-resisting elements
23 Active fire curtain/barrier assemblies
24 Openings
25 Floors and ramps on escape routes
26 Design and construction of common stairs
Section 5: Stairs and final exits
27 Number and siting of common stairs
28 Width of common stairs
29 Enclosure of common stairs
30 Basement stairs
31 Stairs within mixed-use developments
32 Access lobbies and corridors to protected stairways
33 External stairs
34 Discharge from common stairs and final exits
Section 6: Mechanical systems for ducted heating,
ventilation and air conditioning (HVAC)
35 HVAC systems within individual dwellings
36 HVAC systems serving the whole building or
interconnecting dwellings and other residential units
Section 7: Ancillary accommodation to flats and maisonettes
37 General recommendations for ancillary accommodation
38 Places of special fire hazard
39 Installation of engineering services
40 Engineering service installation rooms
41 Gas services, installation and service pipes
42 Electrical services
43 Gas and electricity meters
44 Lighting
45 Lift machine rooms and machinery spaces
46 Communal heating, ventilation and air conditioning
systems
47 Refuse storage, disposal and incineration
48 Car parks and domestic garages
Section 8: Access and facilities for fire-fighting
49 General recommendations for fire-fighting facilities
50 Fire-fighting access
51 Water supplies for fire and rescue service fire-fighting use
52 Information for fire and rescue service use
Section 9: Management
53 Management of specialized housing
54 Evacuation of disabled occupants or occupants that
require assistance to escape
55 Residents
56 Caretakers
57 Maintenance of fire protection measures
58 Maintenance of building plant and equipment
59 Ensuring that systems respond properly in an emergency
Section 10: Building works: Material alterations, extensions,
refurbishment, change of use, disuse, decommissioning
and demolition
60 Design of works
61 Change of use
62 Refurbishments
63 Dwellings in disuse and areas decommissioned
64 Managing building work and material alterations
65 Building works to occupied or partly occupied buildings
Annexes
Annex A (informative) - Methods of smoke ventilation
Annex B (normative) - Additional recommendations for
property protection and business continuity
Annex C (normative) - Atria
Annex D (normative) - Private balconies (open or enclosed)
and communal roof gardens
Annex E (informative) - Management of additional needs
and disabilities
Annex F (informative) - Advice to occupiers of dwellings in
residential buildings
Bibliography
Explains recommendations and guidance on the design, management and use of the following building types, to achieve reasonable standards of fire safety for all people in and around: a) dwellings (single-family dwelling houses, self-contained flats or maisonettes); b) residential accommodation blocks (e.g. for students or hospital staff), with individual bedrooms and the provision of kitchen/sanitary facilities constructed within a fire compartment; c) specialized housing.
Committee |
FSH/14
|
DevelopmentNote |
Supersedes BS 9991(2011) & 15/30301829 DC. (11/2015)
|
DocumentType |
Standard
|
ISBN |
9780580963568
|
Pages |
188
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This British Standard gives recommendations and guidance on the design, management and use of the following building types, to achieve reasonable standards of fire safety for all people in and around: dwellings (single-family dwelling houses, self-contained flats or maisonettes); residential accommodation blocks (e.g. for students or hospital staff), with individual bedrooms and the provision of kitchen/sanitary facilities constructed within a fire compartment; specialized housing. NOTE1 Recommendations for fire safety in the design, management and use of buildings other than residential buildings are given in BS9999. It is not applicable to hotels, caravans/mobile homes, hospitals, residential care homes, places of lawful detention or hostels. NOTE2 Requirements for means of escape from caravans and mobile homes are given in BS3632. This British Standard is applicable to the design of new buildings, and to material alterations, extensions and material change of use of an existing building. NOTE3 Attention is drawn to the Building Regulations 2010 [1] and equivalent regional variations [3] to [5] in respect of the definition of material alterations, extensions and material change of use. It also provides recommendations and guidance on the ongoing management of fire safety in a building throughout the entire life cycle of the building, including measures for designers to ensure that the overall design of a building assists and enhances the management of fire safety. It can be used as a tool for assessing existing buildings, although fundamental change in line with its recommendations might be limited or not practicable. The recommendations and guidance given in this British Standard are intended to safeguard the lives of building occupants and fire-fighters. Whilst some of the recommendations and guidance might also assist in the achievement of other fire safety objectives – such as protection of property, the environment, communities and business/service viability – additional measures might be necessary which are outside the scope of this British Standard. This British Standard does not cover fire safety design strategies for extreme events such as terrorist actions.
I.S. 3218:2013+A1:2019 | Fire detection and alarm systems for buildings - System design, installation, commissioning, servicing and maintenance & Amendment 1:2019 |
BS 5410-2:2013 | Code of practice for oil firing Installations over 45 kW output capacity for space heating, hot water and steam supply services |
BS 5234-2:1992 | Partitions (including matching linings) Specification for performance requirements for strength and robustness including methods of test |
BS 5306-9:2015 | Fire extinguishing installations and equipment on premises Recharging of portable fire extinguishers. Code of practice |
BS 5266-1:2011 | Emergency lighting Code of practice for the emergency escape lighting of premises |
BS EN 1634-1 : 2014 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 1: FIRE RESISTANCE TEST FOR DOOR AND SHUTTER ASSEMBLIES AND OPENABLE WINDOWS |
BS 5306-3:2009 | Fire extinguishing installations and equipment on premises Commissioning and maintenance of portable fire extinguishers. Code of practice |
BS 5234-1:1992 | Partitions (including matching linings) Code of practice for design and installation |
BS EN 1155:1997 | Building hardware. Electrically powered hold-open devices for swing doors. Requirements and test methods |
BS 7273-4:2015 | Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors |
BS 5516-2:2004 | Patent glazing and sloping glazing for buildings Code of practice for sloping glazing |
BS EN 1634-3:2004 | Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware Smoke control test for door and shutter assemblies |
BS 8524-1:2013 | Active fire curtain barrier assemblies Specification |
BS EN 1991-1-2:2002 | Eurocode 1. Actions on structures General actions. Actions on structures exposed to fire |
BS 6262-4:2005 | Glazing for buildings Code of practice for safety related to human impact |
BS DD8458-1(2010) : 2010 | FIXED FIRE PROTECTION SYSTEMS - RESIDENTIAL AND DOMESTIC WATERMIST SYSTEMS - PART 1: CODE OF PRACTICE FOR DESIGN AND INSTALLATION |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 5852:2006 | Methods of test for assessment of the ignitability of upholstered seating by smouldering and flaming ignition sources |
BS EN ISO 1182:2010 | Reaction to fire tests for products. Non-combustibility test |
BS 9990:2015 | Non automatic fire-fighting systems in buildings. Code of practice |
BS 8524-2:2013 | Active fire curtain barrier assemblies Code of practice for application, installation and maintenance |
BS ISO 3864-1:2011 | Graphical symbols. Safety colours and safety signs Design principles for safety signs and safety markings |
DD ENV 1187:2002 | Test methods for external fire exposure to roofs |
BS EN ISO 14122-4:2016 | Safety of machinery. Permanent means of access to machinery Fixed ladders |
BS 7346-8:2013 | Components for smoke control systems Code of practice for planning, design, installation, commissioning and maintenance |
BS EN 12845:2015 | Fixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance |
BS 3632:2005 | Residential park homes. Specification |
BS EN ISO 11925-2:2010 | Reaction to fire tests. Ignitability of products subjected to direct impingement of flame Single-flame source test |
BS 8519:2010 | Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. Code of practice |
BS 7157:1989 | Method of test for ignitability of fabrics used in the construction of large tented structures |
BS EN ISO 1716:2010 | Reaction to fire tests for products. Determination of the gross heat of combustion (calorific value) |
BS 9266:2013 | Design of accessible and adaptable general needs housing. Code of practice |
BS EN 13823 : 2010 | REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - BUILDING PRODUCTS EXCLUDING FLOORINGS EXPOSED TO THE THERMAL ATTACK BY A SINGLE BURNING ITEM |
PD 7974-6:2004 | The application of fire safety engineering principles to fire safety design of buildings Human factors. Life safety strategies. Occupant evacuation, behaviour and condition (Sub-system 6) |
BS 7974:2001 | Application of fire safety engineering principles to the design of buildings. Code of practice |
BS 3251:1976 | Specification. Indicator plates for fire hydrants and emergency water supplies |
BS EN 1154:1997 | Building hardware. Controlled door closing devices. Requirements and test methods |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.