BS EN 12016:2013
Current
The latest, up-to-date edition.
Electromagnetic compatibility. Product family standard for lifts, escalators and moving walks. Immunity
Hardcopy , PDF
English
31-08-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test procedure
5 Applicability of tests
6 Evaluation of tests results
7 Documentation for the installer of the apparatus/assembly
of apparatus
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements
of EU Directive 2004/108/EC
Annex ZB (informative) - Relationship between this European
Standard and the Essential Requirements
of EU Directive 2006/42/EC
Annex ZC (informative) - Relationship between this European
Standard and the Essential Requirements
of EU Directive 95/16/EC
Bibliography
Describes the immunity performance criteria and test levels for apparatus used in lifts, escalators and moving walks which are intended to be permanently installed in buildings including the basic safety requirements in regard to their electromagnetic environment.
Committee |
MHE/4
|
DevelopmentNote |
Supersedes 95/710914 DC. (08/2004) Supersedes 02/700415 DC. (01/2005) Supersedes 11/30253123 DC. (08/2013)
|
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
1.1 This European Standard specifies the immunity performance criteria and test levels for apparatus used in lifts, escalators and moving walks which are intended to be permanently installed in buildings including the basic safety requirements in regard to their electromagnetic environment. These levels represent essential EMC requirements.
The standard refers to EM conditions as existing in residential, office and industrial buildings.
This standard addresses commonly known EMC related hazards and hazardous situations relevant to lifts, escalators and moving walks when they are used as intended and under the conditions foreseen by the lift installer or escalator and/or moving walk manufacturer.
However:
performance criteria and test levels for apparatus/assembly of apparatus used in general function circuits do not cover situations with an extremely low probability of occurrence;
this standard does not apply to other apparatus already proven to be in conformity to the EMC Directive, and not related to the safety of the lift, escalator or moving walk, such as lighting apparatus, communication apparatus, etc.
1.2 This European Standard does not apply to electromagnetic environments such as:
radio-transmitter stations,
railways and metros,
heavy industrial plant,
electricity power station,
which need additional investigations.
1.3 This standard is not applicable to apparatus which were manufactured before the date of its publication as EN 12016.
Standards | Relationship |
UNI EN 12016 : 2013 | Identical |
EN 12016:2013 | Identical |
SN EN 12016 : 2013 | Identical |
UNE-EN 12016:2014 | Identical |
NEN EN 12016 : 2013 | Identical |
DIN EN 12016:2013-12 | Identical |
I.S. EN 12016:2013 | Identical |
NBN EN 12016 : 2013 | Identical |
NF EN 12016 : 2013 | Identical |
NS EN 12016 : 2013 | Identical |
05/30128013 DC : DRAFT JULY 2005 | BS 5655-12 - LIFTS AND SERVICE LIFTS - PART 12: CODE OF PRACTICE FOR THE UNDERTAKING OF MODIFICATIONS TO EXISTING HYDRAULIC LIFTS |
BS 6440:2011 | Powered vertical lifting platforms having non-enclosed or partially enclosed liftways intended for use by persons with impaired mobility. Specification |
BS 5655-11:2005 | Lifts and service lifts Code of practice for the undertaking of modifications to existing electric lifts |
BS 5900:2012 | Powered homelifts with partially enclosed carriers and no liftway enclosures. Specification |
BS 5655-12:2005 | Lifts and service lifts Code of practice for the undertaking of modifications to existing hydraulic lifts |
05/30128010 DC : DRAFT JUL 2005 | BS 5655-11 - LIFTS AND SERVICE LIFTS - PART 11: CODE OF PRACTICE FOR THE UNDERTAKING OF MODIFICATIONS TO EXISTING ELECTRIC LIFTS |
11/30194294 DC : 0 | BS 6440 - POWERED LIFTING PLATFORMS WITH NON-ENCLOSED LIFTWAYS FOR USE BY PERSONS WITH LIMITED MOBILITY - SPECIFICATION |
BS 5655-6:2002 | Lifts and service lifts Code of practice for the selection and installation of new lifts |
BS 5655-6:2011 | Lifts and service lifts Code of practice for the selection, installation and location of new lifts |
04/30089457 DC : DRAFT APR 2004 | BS 5656-2 - SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF ESCALATORS AND PASSENGER CONVEYORS - SELECTION, INSTALLATION AND LOCATION OF NEW ESCALATORS AND MOVING WALKS |
BS 5656-2:2004 | Escalator and moving walks. Safety rules for the construction and installation of escalators and moving walks Code of practice for the selection, installation and location of new escalators and moving walks |
11/30194292 DC : 0 | BS 5900 - POWERED HOME LIFTS WITH FULLY OR PARTIALLY ENCLOSED CARS AND NO LIFT-WELL ENCLOSURES - SPECIFICATION |
11/30229088 DC : 0 | BS 5655-6 - LIFTS AND SERVICE LIFTS - PART 6: CODE OF PRACTICE FOR THE SELECTION AND INSTALLATION OF NEW LIFTS |
IEC 61800-3:2017 | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
EN 55024 : 2010 AMD 1 2015 | INFORMATION TECHNOLOGY EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 24:2010/A1:2015) |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
EN 115-1:2017 | Safety of escalators and moving walks - Part 1: Construction and installation |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 81-1:1998+A3:2009 | Safety rules for the construction and installation of lifts - Part 1: Electric lifts |
ISO 12100:2010 | Safety of machinery — General principles for design — Risk assessment and risk reduction |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
1995/16/EC : 1995 | DIRECTIVE 95/16/EC OF 29 JUNE 1995 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO LIFTS |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 81-2 : 1998 + A3 2009 | SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 2: HYDRAULIC LIFTS |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
EN ISO 12100:2010 | Safety of machinery - General principles for design - Risk assessment and risk reduction (ISO 12100:2010) |
EN 61800-3 : 2004 AMD 1 2012 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004/A1:2011) |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
CISPR 24:2010+AMD1:2015 CSV | Information technology equipment - Immunity characteristics - Limitsand methods of measurement |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.