BS EN 13030:2001
Current
The latest, up-to-date edition.
Ventilation for buildings. Terminals. Performance testing of louvres subjected to simulated rain
Hardcopy , PDF
English
30-11-2001
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and subscripts
4.1 Symbols
4.2 Subscripts
5 Instrumentation
5.1 Air flow rate measurement
5.2 Wind Velocity Measurement
5.3 Pressure Measurement
5.4 Temperature measurement
5.5 Water flow meters
5.6 Timers
5.7 Rain gauge
6 Test apparatus
6.1 General
6.2 Win simulation equipment
6.3 Weather section
6.4 Rain simulation equipment
6.5 Collection duct
6.6 Water collection
6.7 Aerodynamic measurement section
6.8 Mechanical ventilation section
6.9 Test specimen and calibration plate
7 Test methods
7.1 Water penetration test
7.2 Discharge and entry loss coefficient/pressure loss
8 Classification of weather louvers
8.1 General
8.2 Penetration classification
8.3 Discharge and Entry loss coefficient
8.4 Classification nomenclature
Annex A (normative) Simulated ran spray nozzles
Annex B (normative) Water eliminator performance test
B.1 General
B.2 Installation
B.3 Procedure
Annex C (normative) Diagrams of apparatus and typical graphs
Annex D (informative) Typical calculation examples
D.1 Test results
D.2 Entry loss coefficient of entry
D.3 Louvre effectiveness
D.4 Classification
Defines a method for measuring the water rejection performance of louvres subjected to simulated rain and wind pressures, both with and without air flow through the louvre under test. For the purpose of tests in this standard, a 1000 mm x 1000 mm section of weather louvre or the nearest possible blade increment is considered.
Committee |
RHE/2
|
DevelopmentNote |
Supersedes 97/719333 DC (12/2001)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies a method for measuring the water rejection performance of louvres subject to simulated rain and wind pressures, both with and without air flow through the louvre under test. For the purpose of tests in this standard, a 1000 mm ´ 1000 mm section of weather louvre or the nearest possible blade increment is considered. Weather louvres are designed to restrict the passage of water during rainfall while allowing the passage of air into or from an air distribution system or part of a building. They are used in a wide range of applications, where there may be differences in wind speed and direction, levels of local turbulence, rate and droplet size, distribution of rainfall and surface water flow from the surrounding structure. It is impractical to consider a standard test procedure simulating the whole range of likely conditions, but this standard provides for heavy rainfall directed on to the louvre surface, with simulated wind pressures. This provides a common basis on which to compare the water rejection performance of weather louvres of different designs. This standard is not intended for the evaluation of weather performance of pressure relief dampers. The purpose of tests incorporated in this European Standard is as follows: a) Weather tests To establish the weather louvre effectiveness when subjected to wind pressure at various air flow rates. b) Discharge and Entry loss coefficient/Pressure requirements To establish the air pressure loss through the weather louvre at various air flow rates and by calculation the Discharge and Entry Loss Coefficient.
Standards | Relationship |
SN EN 13030 : 2002 | Identical |
UNI EN 13030 : 2005 | Identical |
I.S. EN 13030:2002 | Identical |
UNE-EN 13030:2003 | Identical |
DIN EN 13030:2002-03 | Identical |
NS EN 13030 : 1ED 2002 | Identical |
NF EN 13030 : 2002 | Identical |
EN 13030:2001 | Identical |
NBN EN 13030 : 2002 | Identical |
NEN EN 13030 : 2001 | Identical |
ISO 5801:2017 | Fans — Performance testing using standardized airways |
EN ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003) |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
CR 12792 : 1997 | VENTILATION FOR BUILDINGS - SYMBOLS AND TERMINOLOGY |
ISO 5221:1984 | Air distribution and air diffusion Rules to methods of measuring air flow rate in an air handling duct |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.