Foreword
1 Scope
2 Normative references
3 Terms, definitions and symbols
3.1 Terms and definitions
3.2 Symbols
4 Normal operating conditions
4.1 Flow range
4.2 Maximum working pressure
4.3 Temperature range
4.4 Range of gases
4.5 Orientation
5 Metrological performance
5.1 General
5.2 Mode comparison
5.3 Permissible errors
5.4 Gas - air relationship
5.5 Pressure absorption
5.6 Metrological stability
5.7 Immunity to contaminants in gas stream
5.8 Installation effects
5.9 Zero flow
5.10 Reverse flow
5.11 Low flow registration
5.12 High flow registration
5.13 Pulsed (unsteady) flow
5.14 Temperature sensitivity
6 Construction and materials
6.1 General
6.2 Robustness of meter case
6.3 Corrosion protection
6.4 Casework decorative finish
6.5 Ageing of non-metallic casework
6.6 Ageing of external surfaces of the meter, including
index windows and adhesion of the index window
6.7 Protection against solar radiation
6.8 Resistance to external humidity
6.9 Flame retardance of external surfaces
6.10 Resistance to storage temperature range
6.11 Resistance to the effects of toluene/iso-octane vapour
6.12 Resistance to water vapour
6.13 Ageing
7 Optional features
7.1 Pressure measuring point
7.2 Resistance to high ambient temperature
7.3 Meters with temperature conversion
7.4 Ancillary devices (if fitted)
7.5 Use in hazardous zones
8 Index
8.1 Recording and storage
8.2 Display
8.3 Segmental display
8.4 Non-volatile memory
8.5 Display reset
9 Marking
9.1 All meters
9.2 Two-pipe meters
9.3 Durability and legibility of marking
9.4 Accompanying information
10 Software
10.1 Requirements
10.2 Test
11 Communications
11.1 General
11.2 Character transmission
11.3 Communications protocol
11.4 Data
11.5 Test-mode
11.6 Data optical port
11.7 Galvanic port (optional)
11.8 Diagnostics
12 Battery
12.1 General
12.2 Voltage interruptions
12.3 Minimum operating voltage
12.4 Battery life
13 Immunity to electromagnetic disturbances
13.1 General
13.2 Electrostatic discharge
13.3 Radio frequency electromagnetic field
13.4 Electromagnetic induction (power frequency)
13.5 Electromagnetic induction (pulsed field)
13.6 Radio interference suppression
14 Ultrasonic (acoustic) noise interference
14.1 Requirements
14.2 Test
15 Meters supplied for testing
Annex A (informative) Test gases
A.1 General
A.2 Test gas properties
Annex B (normative) Production requirements for gas meters
B.1 Specification
B.2 Technical requirements
B.3 Certificates of conformity
Annex C (normative) Meters with gas temperature conversion
devices
C.1 Scope
C.2 Metrological performance
Annex ZA (informative) Relationship between this European
Standard and the Essential Requirements
of EU Directive 2004/22 Measuring
Instruments Directive
Bibliography
Specifies requirements and tests for the construction, performance and safety of class 1,0 and class 1,5 battery powered ultrasonic gas meters (hereinafter referred to as meters), having co-axial single pipe, or two pipe connections, used to measure volumes of distributed fuel gases of the second and/or third family, as given in EN 437, at maximum working pressures not exceeding 0,5 bar and maximum actual flow rates of up to 10 m[3]/h over a minimum ambient temperature range of -10 degrees C to +40 degrees C, and minimum gas temperature span of 40 K, for domestic applications.
| Committee |
GSE/25
|
| DevelopmentNote |
Supersedes DD ENV 14236. (03/2007)
|
| DocumentType |
Standard
|
| Pages |
86
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes | |
| UnderRevision |
This European Standard specifies requirements and tests for the construction, performance and safety of class 1,0 and class 1,5 battery powered ultrasonic gas meters (hereinafter referred to as meters), having co-axial single pipe, or two pipe connections, used to measure volumes of distributed fuel gases of the second and/or third family, as given in EN 437, at maximum working pressures not exceeding 0,5 bar ) and maximum actual flow rates of up to 10 m3/h over a minimum ambient temperature range of -10 °C to +40 °C, and minimum gas temperature span of 40 K, for domestic applications. This European Standard applies to meters where the measuring element and the register(s) are enclosed in the same case. This European Standard applies to meters with and without built-in temperature conversion, that are installed in locations with vibration and shocks of low significance and in ? closed locations (indoor or outdoor with protection as specified by the manufacturer) with condensing or with non-condensing humidity or, if specified by the manufacturer, ? open locations (outdoor without any covering) with condensing humidity or with non-condensing humidity and in locations with electromagnetic disturbances. Unless otherwise stated, all pressures given in this European Standard are gauge pressures. When more than one meter type is submitted for testing, then each meter type is required to be tested against this European Standard. Clauses 1 to 15 and Annex C are for design and type testing only. NOTE See Annex A for production requirements.
| Standards | Relationship |
| EN 14236:2007 | Identical |
| NBN EN 14236 : 2007 | Identical |
| NS EN 14236 : 1ED 2007 | Identical |
| I.S. EN 14236:2007 | Identical |
| NF EN 14236 : 2007 | Identical |
| DIN EN 14236:2008-06 | Identical |
| NEN EN 14236 : 2007 | Identical |
| UNE-EN 14236:2007 | Identical |