Foreword
1 Scope
2 Normative references
3 Terms, definitions and symbols
   3.1 Terms and definitions
   3.2 Symbols
4 Normal operating conditions
   4.1 Flow range
   4.2 Maximum working pressure
   4.3 Temperature range
   4.4 Range of gases
   4.5 Orientation
5 Metrological performance
   5.1 General
   5.2 Mode comparison
   5.3 Permissible errors
   5.4 Gas - air relationship
   5.5 Pressure absorption
   5.6 Metrological stability
   5.7 Immunity to contaminants in gas stream
   5.8 Installation effects
   5.9 Zero flow
   5.10 Reverse flow
   5.11 Low flow registration
   5.12 High flow registration
   5.13 Pulsed (unsteady) flow
   5.14 Temperature sensitivity
6 Construction and materials
   6.1 General
   6.2 Robustness of meter case
   6.3 Corrosion protection
   6.4 Casework decorative finish
   6.5 Ageing of non-metallic casework
   6.6 Ageing of external surfaces of the meter, including
        index windows and adhesion of the index window
   6.7 Protection against solar radiation
   6.8 Resistance to external humidity
   6.9 Flame retardance of external surfaces
   6.10 Resistance to storage temperature range
   6.11 Resistance to the effects of toluene/iso-octane vapour
   6.12 Resistance to water vapour
   6.13 Ageing
7 Optional features
   7.1 Pressure measuring point
   7.2 Resistance to high ambient temperature
   7.3 Meters with temperature conversion
   7.4 Ancillary devices (if fitted)
   7.5 Use in hazardous zones
8 Index
   8.1 Recording and storage
   8.2 Display
   8.3 Segmental display
   8.4 Non-volatile memory
   8.5 Display
9 Marking
   9.1 All meters
   9.2 Two-pipe meters
   9.3 Durability and legibility of marking
   9.4 Accompanying information
10 Software
   10.1 Requirements
   10.2 Test
11 Communications
   11.1 General
   11.2 Character transmission
   11.3 Communications protocol
   11.4 Data
   11.5 Test-mode
   11.6 Data optical port
   11.7 Galvanic port (optional)
   11.8 Diagnostics
12 Battery
   12.1 General
   12.2 Voltage interruptions
   12.3 Minimum operating voltage
   12.4 Battery life
13 Immunity to electromagnetic disturbances
   13.1 General
   13.2 Electrostatic discharge
   13.3 Radio frequency electromagnetic field
   13.4 Electromagnetic induction (power frequency)
   13.5 Electromagnetic induction (pulsed field)
   13.6 Radio interference suppression
14 Ultrasonic (acoustic) noise interference
   14.1 Requirements
   14.2 Test
15 Meters supplied for testing
Annex A (informative) Test gases
   A.1 General
   A.2 Test gas properties
Annex B (normative) Production requirements for gas meters
   B.1 Specification
   B.2 Technical requirements
   B.3 Certificates of conformity
Annex C (normative) Meters with gas temperature conversion
                    devices
   C.1 Scope
   C.2 Metrological performance
Annex ZA (informative) Relationship between this European
                       Standard and the Essential Requirements
                       of EU Directive 2004/22 Measuring
                       Instruments Directive
Bibliography

This European Standard specifies requirements and tests for the construction, performance and safety of class 1,0 and class 1,5 battery powered ultrasonic gas meters (hereinafter referred to as meters), having co-axial single pipe, or two pipe connections, used to measure volumes of distributed fuel gases of the second and/or third family, as given in EN 437, at maximum working pressures not exceeding 0,5 bar ) and maximum actual flow rates of up to 10 m3/h over a minimum ambient temperature range of -10 °C to +40 °C, and minimum gas temperature span of 40 K, for domestic applications. This European Standard applies to meters where the measuring element and the register(s) are enclosed in the same case.This European Standard applies to meters with and without built-in temperature conversion, that are installed in locations with vibration and shocks of low significance and inclosed locations (indoor or outdoor with protection as specified by the manufacturer) with condensing or with non-condensing humidityor, if specified by the manufacturer,open locations (outdoor without any covering) with condensing humidity or with non-condensing humidityand in locations with electromagnetic disturbances.Unless otherwise stated, all pressures given in this European Standard are gauge pressures.When more than one meter type is submitted for testing, then each meter type is required to be tested against this European Standard.Clauses 1 to 15 and Annex C are for design and type testing only.NOTESee Annex A for production requirements.

Committee
CEN/TC 237
DevelopmentNote
Supersedes ENV 14236. (02/2007)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
NBN EN 14236 : 2007 Identical
BS EN 14236:2007 Identical
PN EN 14236 : 2010 Identical
NS EN 14236 : 1ED 2007 Identical
I.S. EN 14236:2007 Identical
I.S. EN 14236:2018 Identical
NF EN 14236 : 2007 Identical
NS-EN 14236:2018 Identical
DIN EN 14236:2008-06 Identical
NEN EN 14236 : 2007 Identical
NEN EN 14236 : 2018en Identical
DS EN 14236 : 2007 Identical
UNE-EN 14236:2007 Identical

Sorry this product is not available in your region.