BS EN 14246:2006
Current
The latest, up-to-date edition.
Gypsum elements for suspended ceilings. Definitions, requirements and test methods
Hardcopy , PDF
English
31-08-2007
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Types of gypsum ceiling elements for suspended ceilings
4.1 General
4.2 Gypsum units
4.3 Gypsum tiles
5 Requirements
5.1 Fire behaviour
5.2 Water vapour permeability (expressed as water vapour
resistance factor)
5.3 Flexural strength (expressed as flexural breaking load)
5.4 Acoustic properties
5.5 Thermal properties - Thermal resistance (expressed as
thermal conductivity)
5.6 Regulated substances
5.7 Appearance
5.8 Dimensions and tolerances
5.9 Squareness
5.10 Flatness (not for tiles with decorative face)
5.11 Mass per unit of surface and tolerance
5.12 Moisture content
5.13 pH
6 Test methods
6.1 Sampling
6.2 Preparation of the test specimens
6.3 Determination of flexural strength
6.4 Determination of surface appearance
6.5 Measurement of dimensions
6.6 Determination of squareness
6.7 Determination of flatness (not for gypsum elements with
decorated faces)
6.8 Determination of the mass per surface unit
6.9 Determination of the moisture content
6.10 pH measurement
6.11 Test report
7 Evaluation of conformity
7.1 General
7.2 Type testing
7.3 Factory production control (FPC)
8 Designation
9 Marking, labelling and packaging
Annex A (informative) Sampling procedure for testing
A.1 General
A.2 Sampling procedure
Annex ZA (informative) Clauses of this European Standard
addressing provisions of EU Construction
Products Directive
ZA.1 Scope and relevant characteristics
ZA.2 Attestation and declaration of conformity of
gypsum elements for suspended ceilings
ZA.3 CE Marking and labelling
Bibliography
Defines the characteristics and performance of factory made cast gypsum elements, for which the main intended uses are the construction of suspended ceilings under universal substrates.
Committee |
B/544
|
DevelopmentNote |
Supersedes 01/105976 DC (07/2006)
|
DocumentType |
Standard
|
Pages |
38
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This European Standard specifies the characteristics and performance of factory made cast gypsum elements, for which the main intended uses are the construction of suspended ceilings under universal substrates.
It covers the following product performance characteristics: reaction to fire, water vapour permeability, flexural strength (expressed as breaking load) and thermal resistance (expressed as thermal conductivity).
The following performance characteristics are linked to systems assembled with gypsum elements for suspended ceilings: fire resistance, direct airborne sound insulation and acoustic absorption, which can be measured according to the corresponding European test methods. If required, tests should be done on assembled system simulating the end use conditions.
This European Standard describes the reference tests for technical specifications.
This European Standard also covers additional technical characteristics that are of importance for the use and the acceptance of the product by the construction industry and the reference tests for these characteristics.
It provides for the evaluation of conformity of the product to this European Standard.
This European Standard does not cover metal ceiling grids or plasterboard products.
This European Standard excludes stiffening timber roof truss structure applications.
Standards | Relationship |
I.S. EN 14246:2006 | Identical |
UNI EN 14246 : 2006 | Identical |
NEN EN 14246 : 2006 C1 2007 | Identical |
NS EN 14246 : 2006 AC 2007 | Identical |
SN EN 14246 : 2006 | Identical |
NF EN 14246 : 2006 | Identical |
NBN EN 14246 : 2006 COR 2007 | Identical |
DIN EN 14246:2006-09 | Identical |
UNE-EN 14246:2007 | Identical |
EN 14246:2006/AC:2007 | Identical |
EN 14246:2006 | Equivalent |
ISO 354:2003 | Acoustics — Measurement of sound absorption in a reverberation room |
ISO 140-3:1995 | Acoustics — Measurement of sound insulation in buildings and of building elements — Part 3: Laboratory measurements of airborne sound insulation of building elements |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
EN 13964:2014 | Suspended ceilings - Requirements and test methods |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
EN 12524 : 2000 | BUILDING MATERIALS AND PRODUCTS - HYGROTHERMAL PROPERTIES - TABULATED DESIGN VALUES |
EN ISO 6946:2017 | Building components and building elements - Thermal resistance and thermal transmittance - Calculation methods (ISO 6946:2017, Corrected version 2021-12) |
EN ISO 12572:2016 | Hygrothermal performance of building materials and products - Determination of water vapour transmission properties - Cup method (ISO 12572:2016) |
EN ISO 354:2003 | Acoustics - Measurement of sound absorption in a reverberation room (ISO 354:2003) |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 717-1:2013 | Acoustics Rating of sound insulation in buildings and of building elements Part 1: Airborne sound insulation |
ISO 6946:2017 | Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.