EN 13501-2:2016
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
31-12-2016
22-06-2016
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Fire scenarios
5 Resistance to fire performance characteristics
6 Declaration of fire resistance performance
7 Classification procedure for fire resistance
Annex A (normative) - Classification report
Annex B (informative) - Presentation of characterization
data and their field of application for products
and systems for protecting elements or parts of
work
Bibliography
This European Standard specifies the procedure for classification of construction products and building elements using data from fire resistance and smoke leakage tests which are within the direct field of application of the relevant test method. Classification on the basis of extended application of test results is also included in the scope of this European Standard."This European Standard deals with:a)loadbearing elements without a fire separating function:walls;floors;roofs;beams;columns;balconies;walkways;stairs.b)loadbearing elements with a fire separating function, with or without glazing, services and fixtures:walls;floors;roofs;raised floors.c)products and systems for protecting elements or parts of the works:ceilings with no independent fire resistance;fire protective coatings, claddings and screens;d)non-loadbearing elements or parts of works, with or without glazing, services and fixtures:partitions;facades (curtain walls) and external walls;ceilings with independent fire resistance;raised floorsfire doors and shutters and their closing devices;smoke control doors;conveyor systems and their closures;penetration seals;linear gap seals;service ducts and shafts;chimneys.e)wall and ceiling coverings with fire protection ability.f)lift landing doors which are tested according to EN 81-58 are excluded from this European Standard. Lift landing doors which are tested in accordance with EN 1634-1, are classified in accordance with 7.5.5.Relevant test methods which have been prepared for these elements are listed in Clauses 2 and 7.
Committee |
CEN/TC 127
|
DevelopmentNote |
Supersedes PREN 13501-2. (06/2016)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Supersedes |
Standards | Relationship |
NEN EN 13501-2 : 2016 | Identical |
SN EN 13501-2 : 2016 | Identical |
NS EN 13501-2 : 2007 + A1 2009 | Identical |
I.S. EN 13501-2:2016 | Identical |
NF EN 13501-2 : 2016 | Identical |
UNE-EN 13501-2:2009 | Identical |
NS-EN 13501-2:2016 | Identical |
NBN EN 13501-2 : 2016 | Identical |
BS EN 13501-2 : 2007 | Identical |
UNI EN 13501-2 : 2009 | Identical |
DIN EN 13501-2:2015-11 (Draft) | Identical |
DS EN 13501-2 : 2016 | Identical |
ONORM EN 13501-2 : 2016 | Identical |
DIN EN 13501-2:2003-12 | Identical |
UNI EN 13501-2 : 2016 | Identical |
UNE-EN 13501-2:2019 | Identical |
PN EN 13501-2 : 2016 | Identical |
BS EN 13501-2:2016 | Identical |
PREN 13658-2 : DRAFT 2017 | METAL LATH AND BEADS - DEFINITIONS, REQUIREMENTS AND TEST METHODS - PART 2: EXTERNAL RENDERING |
PREN 15497 : DRAFT 2011 | STRUCTURAL FINGER JOINTED SOLID TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
08/30188125 DC : 0 | BS EN 15269-3 - EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 3: TIMBER HINGED AND PIVOTED DOORSETS |
BS EN 14509:2013 | Self-supporting double skin metal faced insulating panels. Factory made products. Specifications |
UNI EN 15998 : 2011 | GLASS IN BUILDING - SAFETY IN CASE OF FIRE, FIRE RESISTANCE - GLASS TESTING METHODOLOGY FOR THE PURPOSE OF CLASSIFICATION |
17/30347436 DC : 0 | BS EN 15269-1 - EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 1: GENERAL REQUIREMENTS |
DIN EN 15882-3:2009-07 | EXTENDED APPLICATIONS OF RESULTS FROM FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS |
I.S. EN 15681-2:2017 | GLASS IN BUILDING - BASIC ALUMINO SILICATE GLASS PRODUCTS - PART 2: PRODUCT STANDARD |
15/30328765 DC : 0 | BS EN 12602 - PREFABRICATED REINFORCED COMPONENTS OF AUTOCLAVED AERATED CONCRETE |
DIN EN 15269-2:2012-12 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 2: Fire resistance of hinged and pivoted steel doorsets |
I.S. EN 15269-1:2010 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 1: GENERAL REQUIREMENTS |
CEN/TR 14819-2:2005 | Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 2: Other funicular railways and other installations |
I.S. EN 15269-7:2009 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 7: FIRE RESISTANCE FOR STEEL SLIDING DOORSETS |
11/30251988 DC : 0 | BS EN 14190 - GYPSUM PLASTERBOARD PRODUCTS FROM PROCESSING - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
DIN EN 15269-20:2009-12 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 20: Smoke control for hinged and pivoted steel, timber and metal framed glazed doorsets |
I.S. EN 15269-5:2014 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 5: FIRE RESISTANCE OF HINGED AND PIVOTED METAL FRAMED GLAZED DOORSETS AND OPENABLE WINDOWS |
PREN 13279-1 : DRAFT 2017 | GYPSUM BINDERS AND GYPSUM PLASTERS - PART 1: DEFINITIONS AND REQUIREMENTS |
UNI EN 1634-2 : 2009 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES AND ELEMENTS OF BUILDING HARDWARE - PART 2: FIRE RESISTANCE CHARACTERISATION TEST FOR ELEMENTS OF BUILDING HARDWARE |
BS EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows. Product standard, performance characteristics. Fire resisting and/or smoke control characteristics |
08/30152055 DC : DRAFT APR 2008 | BS EN 50518-1 - MONITORING AND ALARM RECEIVING CENTER - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
BS EN 1364-5:2017 | Fire resistance tests for non-loadbearing elements Air transfer grilles |
BS EN 15682-2:2013 | Glass in building. Heat soaked thermally toughened alkaline earth silicate safety glass Evaluation of conformity/Product standard |
13/30217369 DC : 0 | BS EN 13964 - SUSPENDED CEILINGS - REQUIREMENTS AND TEST METHODS |
BS EN 15269-2:2012 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware Fire resistance of hinged and pivoted steel doorsets |
BS EN 45545-1:2013 | Railway applications. Fire protection on railway vehicles General |
08/30171552 DC : DRAFT JAN 2008 | BS EN 13279-1 - GYPSUM BINDERS AND GYPSUM PLASTERS - PART 1: DEFINITIONS AND REQUIREMENTS |
CEI UNI EN 50518-1 : 2015 | MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
DIN EN 14509:2013-12 | SELF-SUPPORTING DOUBLE SKIN METAL FACED INSULATING PANELS - FACTORY MADE PRODUCTS - SPECIFICATIONS |
I.S. EN 15080-12:2011 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - PART 12: LOADBEARING MASONRY WALLS |
07/30166420 DC : DRAFT AUG 2007 | BS EN 1520 - PREFABRICATED REINFORCED COMPONENTS OF LIGHTWEIGHT AGGREGATE CONCRETE WITH OPEN STRUCTURE |
13/30267101 DC : 0 | BS EN 15269-11 - EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 11: FIRE RESISTANCE OF OPERABLE FABRIC CURTAINS |
BS EN 16309 : 2014 | SUSTAINABILITY OF CONSTRUCTION WORKS - ASSESSMENT OF SOCIAL PERFORMANCE OF BUILDINGS - CALCULATION METHODOLOGY |
PREN 13658-1 : DRAFT 2017 | METAL LATH AND BEADS - DEFINITIONS, REQUIREMENTS AND TEST METHODS - PART 1: INTERNAL PLASTERING |
10/30212126 DC : 0 | BS EN 845-2 - SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 2: LINTELS |
PREN 15254-4 : DRAFT 2016 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
PREN 572-9 : DRAFT 2017 | GLASS IN BUILDING - BASIC SODA LIME SILICATE GLASS PRODUCTS - PART 9: PRODUCT STANDARD |
16/30336421 DC : 0 | BS EN 81-58 - SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - EXAMINATION AND TESTS - PART 58: LANDING DOORS FIRE RESISTANCE TEST |
16/30330693 DC : 0 | BS EN 15254-5 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 5: METAL SANDWICH PANEL CONSTRUCTION |
17/30309558 DC : 0 | BS IEC 60772 ED 2.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION SYSTEMS IMPORTANT TO SAFETY - ELECTRICAL PENETRATION ASSEMBLIES IN CONTAINMENT STRUCTURES |
NF EN 15998 : 2011 | GLASS IN BUILDING - SAFETY IN CASE OF FIRE, FIRE RESISTANCE - GLASS TESTING METHODOLOGY FOR THE PURPOSE OF CLASSIFICATION |
UNE-EN 16623:2015 | Paints and varnishes - Reactive coatings for fire protection of metallic substrates - Definitions, requirements, characteristics and marking |
UNI EN 16240 : 2014 | LIGHT TRANSMITTING FLAT SOLID POLYCARBONATE (PC) SHEETS FOR INTERNAL AND EXTERNAL USE IN ROOFS, WALLS AND CEILINGS - REQUIREMENTS AND TEST METHODS |
I.S. EN 15269-20:2009 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 20: SMOKE CONTROL FOR HINGED AND PIVOTED STEEL, TIMBER AND METAL FRAMED GLAZED DOORSETS |
DIN EN 15254-7:2012-09 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING CEILINGS - PART 7: METAL SANDWICH PANEL CONSTRUCTION |
PREN 1364-3 : DRAFT 2011 | FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 3: CURTAIN WALLING - FULL CONFIGURATION (COMPLETE ASSEMBLY) |
PREN 14081-1 : DRAFT 2013 | TIMBER STRUCTURES - STRENGTH GRADED STRUCTURAL TIMBER WITH RECTANGULAR CROSS SECTION - PART 1: GENERAL REQUIREMENTS |
DIN EN 1364-5:2017-09 | Fire resistance tests for non-loadbearing elements - Part 5: Air transfer grilles |
UNE-EN 45545-1:2013 | Railway applications - Fire protection on railway vehicles - Part 1: General |
PREN 1364-4 : DRAFT 2011 | FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 4: CURTAIN WALLING - PART CONFIGURATION |
ISO/TS 19880-1:2016 | Gaseous hydrogen Fuelling stations Part 1: General requirements |
DIN EN 15254-4:2013-10 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
CEN/TR 14819-1:2004 | Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 1: Funicular railways in tunnels |
S.R. CEN TS 1992-4-1:2009 | DESIGN OF FASTENINGS FOR USE IN CONCRETE - PART 4-1: GENERAL |
I.S. EN 16034:2014 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS |
BS EN 16153 : 2013 | LIGHT TRANSMITTING FLAT MULTIWALL POLYCARBONATE (PC) SHEETS FOR INTERNAL AND EXTERNAL USE IN ROOFS, WALLS AND CEILINGS - REQUIREMENTS AND TEST METHODS |
UNE-EN 15882-4:2013 | Extended application of results from fire resistance tests for service installations - Part 4: Linear joint seals |
I.S. EN 45545-3:2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 3: FIRE RESISTANCE REQUIREMENTS FOR FIRE BARRIERS |
DIN EN 15254-5:2010-04 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 5: METAL SANDWICH PANEL CONSTRUCTION |
PREN 12602 : DRAFT 2015 | PREFABRICATED REINFORCED COMPONENTS OF AUTOCLAVED AERATED CONCRETE |
UNI EN 16034 : 2014 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS |
UNI CEI EN 45545-1 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 1: GENERAL |
CEI UNI EN 45545-3 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 3: FIRE RESISTANCE REQUIREMENTS FOR FIRE BARRIERS |
DD CEN/TS 1992-4-1:2009 | Design of fastenings for use in concrete General |
UNI CEI EN 50518-1 : 2014 | MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
17/30360105 DC : 0 | BS EN 1748-1-2 - GLASS IN BUILDING - SPECIAL BASIC PRODUCTS - BOROSILICATE FLOAT GLASS - PART 1-2: PRODUCT STANDARD |
UNI EN 1279-5 : 2010 | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY |
UNI EN 1090-1 : 2012 | EXECUTION OF STEEL STRUCTURES AND ALUMINIUM STRUCTURES - PART 1: REQUIREMENTS FOR CONFORMITY ASSESSMENT OF STRUCTURAL COMPONENTS |
UNI EN 15682-2 : 2013 | GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED ALKALINE EARTH SILICATE SAFETY GLASS - PART 2: EVALUATION OF CONFORMITY/PRODUCT STANDARD |
I.S. EN 14963:2006 | ROOF COVERINGS - CONTINUOUS ROOFLIGHTS OF PLASTICS WITH OR WITHOUT UPSTANDS - CLASSIFICATION, REQUIREMENTS AND TEST METHODS |
DIN EN 1096-4:2015-06 (Draft) | GLASS IN BUILDING - COATED GLASS - PART 4: EVALUATION OF CONFORMITY/PRODUCT STANDARD |
I.S. EN 1634-1:2014 | Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows |
I.S. EN 14915:2013 | SOLID WOOD PANELLING AND CLADDING - CHARACTERISTICS, EVALUATION OF CONFORMITY AND MARKING |
EN 14915:2013+A1:2017 | Solid wood panelling and cladding - Characteristics, requirements and marking |
DIN EN 1993-1-2:2010-12 | Eurocode 3: Design of steel structures - Part 1-2: General rules - Structural fire design (includes Corrigendum AC:2009) |
DIN EN 1364-3:2014-05 | FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 3: CURTAIN WALLING - FULL CONFIGURATION (COMPLETE ASSEMBLY) |
BS EN 13063-2:2005 | Chimneys. System chimneys with clay/ceramic flue liners Requirements and test methods under wet conditions |
BS EN 14471 : 2013 | CHIMNEYS - SYSTEM CHIMNEYS WITH PLASTIC FLUE LINERS - REQUIREMENTS AND TEST METHODS |
BS EN 845-2 : 2013 | SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 2: LINTELS |
13/30280057 DC : 0 | BS EN 13782 - TEMPORARY STRUCTURE - TENTS - SAFETY |
BS EN 13063-3:2007 | Chimneys. System chimneys with clay/ceramic flue liners Requirements and test methods for air flue system chimneys |
BS EN 14620-4:2006 | Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0°C and -165°C Insulation components |
BS EN 179:2008 | Building hardware. Emergency exit devices operated by a lever handle or push pad, for use on escape routes. Requirements and test methods |
BS EN 12337-2:2004 | Glass in building. Chemically strengthed soda lime silicate glass Evaluation of conformity/Product standard |
BS EN 14190:2014 | Gypsum board products from reprocessing. Definitions, requirements and test methods |
BS EN 1634-3:2004 | Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware Smoke control test for door and shutter assemblies |
BS EN 12209:2016 | Building hardware. Mechanically operated locks and locking plates. Requirements and test methods |
BS EN 438-7:2005 | High-pressure decorative laminates (HPL). Sheets based on thermosetting resins (usually called laminates) Compact laminate and HPL composite panels for internal and external wall and ceiling finishes |
BS EN 357:2004 | Glass in building. Fire resistant glazed elements with transparent or translucent glass products. Classification of fire resistance |
UNE-EN 14496:2017 | Gypsum based adhesives for thermal/acoustic insulation composite panels and gypsum boards - Definitions, requirements and test methods |
BS EN 13658-2:2005 | Metal lath and beads. Definitions, requirements and test methods External rendering |
BS EN 303-5:2012 | Heating boilers Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW. Terminology, requirements, testing and marking |
BS EN 520 : 2004 | GYPSUM PLASTERBOARDS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
BS EN 14989-1:2007 | Chimneys. Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications Vertical air/flue terminals for C6-type appliances |
I.S. EN 1364-3:2014 | FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 3: CURTAIN WALLING - FULL CONFIGURATION (COMPLETE ASSEMBLY) |
DIN EN 13815:2006-12 | Fibrous gypsum plaster casts - Definitions, requirements and test methods |
EN 13069:2005 | Chimneys - Clay/ceramic outer walls for system chimneys - Requirements and test methods |
DIN EN 15254-2:2009-10 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 2: MASONRY AND GYPSUM BLOCKS |
CEN/TS 1992-4-1:2009 | Design of fastenings for use in concrete - Part 4-1: General |
DIN EN 13063-3:2007-10 | CHIMNEYS - SYSTEM CHIMNEYS WITH CLAY/CERAMIC FLUE LINERS - PART 3: REQUIREMENTS AND TEST METHODS FOR AIR FLUE SYSTEM CHIMNEYS |
DIN EN 13830:2015-07 | CURTAIN WALLING - PRODUCT STANDARD |
DIN EN 14496:2017-09 | GYPSUM BASED ADHESIVES FOR THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS AND GYPSUM BOARDS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
EN 12602:2016 | Prefabricated reinforced components of autoclaved aerated concrete |
EN 12391-1:2003 | Chimneys - Execution standard for metal chimneys - Part 1: Chimneys for non-roomsealed heating appliances |
DIN EN 14209:2017-09 | PREFORMED PLASTERBOARD CORNICES - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
EN 12337-2:2004 | Glass in building - Chemically strengthened soda lime silicate glass - Part 2: Evaluation of conformity/Product standard |
EN 12859:2011 | Gypsum blocks - Definitions, requirements and test methods |
EN 12150-2:2004 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 1090-1:2009+A1:2011 | Execution of steel structures and aluminium structures - Part 1: Requirements for conformity assessment of structural components |
EN 50518-1:2013 | MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
DIN EN 15725:2012-05 | Extended application reports on the fire performance of construction products and building elements (includes Corrigendum AC:2012) |
DIN EN 13915:2017-09 | PREFABRICATED GYPSUM PLASTERBOARD PANELS WITH A CELLULAR PAPERBOARD CORE - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
EN 50583-2:2016 | Photovoltaics in buildings - Part 2: BIPV systems |
EN 13063-1:2005+A1:2007 | Chimneys - System chimneys with clay/ceramic flue liners - Part 1: Requirements and test methods for sootfire resistance |
EN 13024-2:2004 | Glass in building - Thermally toughened borosilicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 45545-3:2013 | Railway applications - Fire protection on railway vehicles - Part 3: Fire resistance requirements for fire barriers |
EN 14250:2010 | Timber structures - Product requirements for prefabricated structural members assembled with punched metal plate fasteners |
EN 13200-7:2014 | Spectator facilities - Part 7: Entry and exit elements and routes |
EN 1366-7:2004 | Fire resistance tests for service installations - Part 7: Conveyor systems and their closures |
DIN EN 15287-2:2008-06 | Chimneys - Design, installation and commissioning of chimneys - Part 2: Chimneys for roomsealed appliances |
PREN 13830 : DRAFT 2013 | CURTAIN WALLING - PRODUCT STANDARD |
UNI EN 16309 : 2014-10 | SUSTAINABILITY OF CONSTRUCTION WORKS - ASSESSMENT OF SOCIAL PERFORMANCE OF BUILDINGS - CALCULATION METHODOLOGY |
DIN EN 15882-4:2012-07 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 4: LINEAR JOINT SEALS |
CEI UNI EN 45545-1 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 1: GENERAL |
DIN EN 15682-2:2013-10 | GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED ALKALINE EARTH SILICATE SAFETY GLASS - PART 2: EVALUATION OF CONFORMITY/PRODUCT STANDARD |
UNI EN 15269-3 : 2012 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 3: FIRE RESISTANCE OF HINGED AND PIVOTED TIMBER DOORSETS AND OPENABLE TIMBER FRAMED WINDOWS |
BS EN 15283-1 : 2008 | GYPSUM BOARDS WITH FIBROUS REINFORCEMENT - DEFINITIONS, REQUIREMENTS AND TEST METHODS - PART 1: GYPSUM BOARDS WITH MAT REINFORCEMENT |
UNE-EN 13200-7:2014 | Spectator facilities - Part 7: Entry and exit elements and routes |
UNE-EN 15683-2:2014 | Glass in building - Thermally toughened soda lime silicate channel shaped safety glass - Part 2: Evaluation of conformity/Product standard |
UNE-EN 15269-10:2015 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies including their elements of building hardware - Part 10: Fire resistance of steel rolling shutter assemblies |
13/30266550 DC : 0 | BS EN 14509 - SELF-SUPPORTING DOUBLE SKIN METAL FACED INSULATING PANELS - FACTORY MADE PRODUCTS - SPECIFICATIONS |
10/30218654 DC : 0 | BS EN 12859 - GYPSUM BLOCKS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
11/30237554 DC : 0 | BS EN 14732 - TIMBER STRUCTURES - PREFABRICATED WALL, FLOOR AND ROOF ELEMENTS - REQUIREMENTS |
UNI EN 15269-7 : 2009 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 7: FIRE RESISTANCE FOR STEEL SLIDING DOORSETS |
DIN EN 16623:2015-04 | PAINTS AND VARNISHES - REACTIVE COATINGS FOR FIRE PROTECTION OF METALLIC SUBSTRATES - DEFINITIONS, REQUIREMENTS, CHARACTERISTICS AND MARKING |
BS EN 1090-1 : 2009 | EXECUTION OF STEEL STRUCTURES AND ALUMINIUM STRUCTURES - PART 1: REQUIREMENTS FOR CONFORMITY ASSESSMENT OF STRUCTURAL COMPONENTS |
BS EN 15681-2:2017 | Glass in Building. Basic alumino silicate glass products Product standard |
PREN 45545-3 : DRAFT 2010 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 3: FIRE RESISTANCE REQUIREMENTS FOR FIRE BARRIERS |
BS EN 50583-1:2016 | Photovoltaics in buildings BIPV modules |
BS EN 50583-2:2016 | Photovoltaics in buildings BIPV systems |
I.S. EN 12391-1:2004 | CHIMNEYS - EXECUTION STANDARD FOR METAL CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOMSEALED HEATING APPLIANCES |
UNI EN 15283-2 : 2009 | GYPSUM BOARDS WITH FIBROUS REINFORCEMENT - DEFINITIONS, REQUIREMENTS AND TEST METHODS - PART 2: GYPSUM FIBRE BOARDS |
12/30255284 DC : DRAFT APR 2012 | BS EN 1096-4 - GLASS IN BUILDING - COATED GLASS - PART 4: EVALUATION OF CONFORMITY - PRODUCT STANDARD |
DIN EN 15283-2:2009-12 | Gypsum boards with fibrous reinforcement - Definitions, requirements and test methods - Part 2: Gypsum fibre boards (includes Amendment A1:2009) |
PREN 14178-2 : DRAFT 2017 | GLASS IN BUILDING - BASIC ALKALINE EARTH SILICATE GLASS PRODUCTS - PART 2: PRODUCT STANDARD |
09/30188385 DC : 0 | BS EN 15269-2 - EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 2: FIRE RESISTANCE OF HINGED AND PIVOTED STEEL DOORSETS |
DIN EN 45545-1:2013-08 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 1: GENERAL |
10/30211850 DC : 0 | BS EN 16034 - PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS |
BS EN 16623:2015 | Paints and varnishes. Reactive coatings for fire protection of metallic substrates. Definitions, requirements, characteristics and marking |
DIN EN 15497:2014-07 | STRUCTURAL FINGER JOINTED SOLID TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
17/30354239 DC : 0 | BS EN 13369 - COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
12/30261882 DC : 0 | BS EN 14081-1 - TIMBER STRUCTURES - STRENGTH GRADED STRUCTURAL TIMBER WITH RECTANGULAR CROSS-SECTION - PART 1: GENERAL REQUIREMENTS |
DIN EN 15287-1:2010-12 | Chimneys - Design, installation and commissioning of chimneys - Part 1: Chimneys for non-roomsealed heating appliances (includes Amendment A1:2010) |
UNE-EN 1090-1:2011 | Execution of steel structures and aluminium structures - Part 1: Requirements for conformity assessment of structural components |
I.S. EN 15283-1:2008 | GYPSUM BOARDS WITH FIBROUS REINFORCEMENT - DEFINITIONS, REQUIREMENTS AND TEST METHODS - PART 1: GYPSUM BOARDS WITH MAT REINFORCEMENT |
UNI EN 15283-1 : 2009 | GYPSUM BOARDS WITH FIBROUS REINFORCEMENT - DEFINITIONS, REQUIREMENTS AND TEST METHODS - PART 1: GYPSUM BOARDS WITH MAT REINFORCEMENT |
11/30236369 DC : 0 | BS EN 14080 - TIMBER STRUCTURES - GLUED LAMINATED TIMBER AND GLUED SOLID TIMBER |
09/30203195 DC : 0 | BS EN 15497 - FINGER JOINTED STRUCTURAL TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
BS EN 16351:2015 | Timber structures. Cross laminated timber. Requirements |
UNI EN 15080-12 : 2011 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - PART 12: LOADBEARING MASONRY WALLS |
UNE-EN 45545-3:2013 | Railway applications - Fire protection on railway vehicles - Part 3: Fire resistance requirements for fire barriers |
13/30281348 DC : 0 | BS EN 13830 - CURTAIN WALLING - PRODUCT STANDARD |
10/30218985 DC : DRAFT JUNE 2010 | BS EN 13369 - COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
11/30250549 DC : 0 | BS EN 14471 - CHIMNEYS - SYSTEM CHIMNEYS WITH PLASTIC FLUE LINERS - REQUIREMENTS AND TEST METHODS |
PREN 1748-1-2 : DRAFT 2017 | GLASS IN BUILDING - SPECIAL BASIC PRODUCTS - BOROSILICATE FLOAT GLASS - PART 1-2: PRODUCT STANDARD |
BS EN 81-58:2003 | Safety rules for the construction and installation of lifts Examination and tests. Landing doors fire resistance test |
UNI CEN/TS 1992-4-1 : 2009 | DESIGN OF FASTENINGS FOR USE IN CONCRETE - PART 4-1: GENERAL |
I.S. EN 1096-4:2004 | GLASS IN BUILDING - COATED GLASS - PART 4: EVALUATION OF CONFORMITY/PRODUCT STANDARD |
I.S. EN 13200-7:2014 | SPECTATOR FACILITIES - PART 7: ENTRY AND EXIT ELEMENTS AND ROUTES |
BS EN 1999-1-2:2007 | Eurocode 9. Design of aluminium structures Structural fire design |
I.S. EN 15998:2010 | GLASS IN BUILDING - SAFETY IN CASE OF FIRE, FIRE RESISTANCE - GLASS TESTING METHODOLOGY FOR THE PURPOSE OF CLASSIFICATION |
FM 4100 : 1988 | FIRE DOOR ASSEMBLIES |
PREN 14374 : DRAFT 2016 | TIMBER STRUCTURES - LAMINATED VENEER LUMBER (LVL) - REQUIREMENTS |
PREN 12150-2 : DRAFT 2017 | GLASS IN BUILDING - THERMALLY TOUGHENED SODA LIME SILICATE SAFETY GLASS - PART 2: PRODUCT STANDARD |
DIN EN 15269-1:2010-07 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 1: GENERAL REQUIREMENTS |
UNI EN 15497 : 2014 | STRUCTURAL FINGER JOINTED SOLID TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
PREN 1748-2-2 : DRAFT 2017 | GLASS IN BUILDING - SPECIAL BASIC PRODUCTS - GLASS CERAMICS - PART 2-2: PRODUCT STANDARD |
PREN 303-5 : DRAFT 2010 | CENTRAL-HEATING BOILERS - PART 5: HEATING BOILERS FOR SOLID FUELS, HAND AND AUTOMATICALLY STOKED, NOMINAL HEAT OUTPUT OF UP TO 500 KW - TERMINOLOGY, REQUIREMENTS, TESTING AND MARKING |
S.R. CEN/TR 12101-4:2009 | SMOKE AND HEAT CONTROL SYSTEMS - PART 4: INSTALLED SHEVS SYSTEMS FOR SMOKE AND HEAT VENTILATION |
BS EN 15269-1:2010 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware General requirements |
I.S. EN 14081-1:2016 | TIMBER STRUCTURES - STRENGTH GRADED STRUCTURAL TIMBER WITH RECTANGULAR CROSS SECTION - PART 1: GENERAL REQUIREMENTS |
BS EN 13369:2013 | Common rules for precast concrete products |
I.S. EN 16035:2012 | HARDWARE PERFORMANCE SHEET (HPS) - IDENTIFICATION AND SUMMARY OF TEST EVIDENCE TO FACILITATE THE INTER-CHANGEABILITY OF BUILDING HARDWARE FOR APPLICATION TO FIRE RESISTING AND/OR SMOKE CONTROL DOORSETS AND/OR OPENABLE WINDOWS |
UNI EN 15269-10 : 2011 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 10: FIRE RESISTANCE OF STEEL ROLLING SHUTTER ASSEMBLIES |
I.S. EN 13369:2013 | COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
UNE-EN 15725:2011 | Extended application reports on the fire performance of construction products and building elements |
DIN EN 15681-2:2015-07 (Draft) | GLASS IN BUILDING - BASIC ALUMINO SILICATE GLASS PRODUCTS - PART 2: PRODUCT STANDARD |
PREN 14471 : DRAFT 2011 | CHIMNEYS - SYSTEM CHIMNEYS WITH PLASTIC FLUE LINERS - REQUIREMENTS AND TEST METHODS |
PREN 15269-1 : DRAFT 2017 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 1: GENERAL REQUIREMENTS |
UNI EN 15287-1 : 2010 | CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOMSEALED HEATING APPLIANCES |
UNI EN 15287-2 : 2008 | CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 2: CHIMNEYS FOR ROOM-SEALED APPLIANCES |
UNI EN 15254-5 : 2009 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 5: METAL SANDWICH PANEL CONSTRUCTION |
I.S. EN 1364-5:2017 | FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 5: AIR TRANSFER GRILLES |
I.S. EN 16309:2014 | SUSTAINABILITY OF CONSTRUCTION WORKS - ASSESSMENT OF SOCIAL PERFORMANCE OF BUILDINGS - CALCULATION METHODOLOGY |
15/30319715 DC : 0 | BS EN 1279-5 - GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY |
17/30353865 DC : 0 | BS EN 1443 - CHIMNEYS - GENERAL REQUIREMENTS |
PREN 14449 : DRAFT 2017 | GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - PRODUCT STANDARD |
I.S. EN 15682-2:2013 | GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED ALKALINE EARTH SILICATE SAFETY GLASS - PART 2: EVALUATION OF CONFORMITY/PRODUCT STANDARD |
UNI EN 15269-20 : 2009 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 20: SMOKE CONTROL FOR HINGED AND PIVOTED STEEL, TIMBER AND METAL FRAMED GLAZED DOORSETS |
UNE-EN 15080-12:2011 | Extended application of results from fire resistance tests - Part 12: Loadbearing masonry walls |
UNE-EN 50518-1:2014 | Monitoring and alarm receiving centre - Part 1: Location and construction requirements |
EN 1096-4:2004 | Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard |
IEC 61936-1:2010+AMD1:2014 CSV | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
DIN EN 12337-2:2005-01 | Glass in building - Chemically strengthened soda lime silicate glass - Part 2: Evaluation of conformity/Product standard; German version EN 12337-2:2004 |
DIN EN 13279-1:2008-11 | GYPSUM BINDERS AND GYPSUM PLASTERS - PART 1: DEFINITIONS AND REQUIREMENTS |
DIN EN 1366-3:2009-07 | Fire resistance tests for service installations - Part 3: Penetration seals |
DIN EN 1748-1-2:2005-01 | Glass in building - Special basic products - Borosilicate glasses - Part 1-2: Evaluation of conformity/Product standard |
DIN EN 572-9:2005-01 | Glass in building - Basic soda lime silicate glass products - Part 9: Evaluation of conformity/Product standard |
DIN EN 1520:2011-06 | Prefabricated reinforced components of lightweight aggregate concrete with open structure with structural or non-structural reinforcement |
DIN EN 1748-2-2:2005-01 | Glass in building - Special basic products - Glass ceramics - Part 2-2: Evaluation of conformity/Product standard |
DIN EN 1364-4:2014-05 | Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration |
DIN EN 14178-2:2005-01 | Glass in Building - Basic alkaline earth silicate glass products - Part 2: Evaluation of conformity/Product standard |
DIN EN 1279-5:2015-08 (Draft) | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY |
DIN EN 14449:2005-07 | Glass in building - Laminated glass and laminated safety glass - Evaluation of conformity/Product standard |
DIN EN 14246:2006-09 | Gypsum elements for suspended ceilings - Definitions, requirements and test methods |
DIN EN 14471:2015-03 | CHIMNEYS - SYSTEM CHIMNEYS WITH PLASTIC FLUE LINERS - REQUIREMENTS AND TEST METHODS |
DIN EN 303-5:2012-10 | Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking |
DIN EN 15318:2008-01 | Design and application of gypsum blocks |
DIN EN 14250:2010-05 | Timber structures - Product requirements for prefabricated structural members assembled with punched metal plate fasteners |
DIN EN 14496:2016-02 (Draft) | GYPSUM BASED ADHESIVES FOR THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS AND GYPSUM BOARDS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
UNE-EN 14080:2013 | Timber structures - Glued laminated timber and glued solid timber - Requirements |
UNE-EN 1364-3:2015 | Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration (complete assembly) |
I.S. EN 13830:2015 | CURTAIN WALLING - PRODUCT STANDARD |
I.S. EN 14471:2013 | CHIMNEYS - SYSTEM CHIMNEYS WITH PLASTIC FLUE LINERS - REQUIREMENTS AND TEST METHODS |
I.S. EN 1364-4:2014 | FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 4: CURTAIN WALLING - PART CONFIGURATION |
I.S. EN 14496:2017 | GYPSUM BASED ADHESIVES FOR THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS AND GYPSUM BOARDS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
I.S. EN 13063-2:2005 | CHIMNEYS - SYSTEM CHIMNEYS WITH CLAY/CERAMIC FLUE LINERS - PART 2: REQUIREMENTS AND TEST METHODS UNDER WET CONDITIONS |
I.S. EN 179:2008 | BUILDING HARDWARE - EMERGENCY EXIT DEVICES OPERATED BY A LEVER HANDLE OR PUSH PAD, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
I.S. EN 14209:2017 | PREFORMED PLASTERBOARD CORNICES - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
DIN EN 12391-1:2004-04 | CHIMNEYS - EXECUTION STANDARD FOR METAL CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOM SEALED HEATING APPLIANCES |
I.S. EN 1520:2011 | PREFABRICATED REINFORCED COMPONENTS OF LIGHTWEIGHT AGGREGATE CONCRETE WITH OPEN STRUCTURE WITH STRUCTURAL OR NON-STRUCTURAL REINFORCEMENT |
I.S. EN 13915:2017 | PREFABRICATED GYPSUM PLASTERBOARD PANELS WITH A CELLULAR PAPERBOARD CORE - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
I.S. EN 1634-3:2004 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 3: SMOKE CONTROL TEST FOR DOOR AND SHUTTER ASSEMBLIES |
DIN EN 1036-2:2008-05 | GLASS IN BUILDING - MIRRORS FROM SILVER-COATED FLOAT GLASS FOR INTERNAL USE - PART 2: EVALUATION OF CONFORMITY - PRODUCT STANDARD |
I.S. EN 520:2005 | GYPSUM PLASTERBOARDS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
I.S. EN 845-2:2013 | SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 2: LINTELS |
I.S. EN 13063-1:2006 | CHIMNEYS - SYSTEM CHIMNEYS WITH CLAY/CERAMIC FLUE LINERS - PART 1: REQUIREMENTS AND TEST METHODS FOR SOOTFIRE RESISTANCE |
I.S. EN 14250:2010 | TIMBER STRUCTURES - PRODUCT REQUIREMENTS FOR PREFABRICATED STRUCTURAL MEMBERS ASSEMBLED WITH PUNCHED METAL PLATE FASTENERS |
I.S. EN 357:2004 | GLASS IN BUILDING - FIRE RESISTANT GLAZED ELEMENTS WITH TRANSPARENT OR TRANSLUCENT GLASS PRODUCTS - CLASSIFICATION OF FIRE RESISTANCE |
I.S. EN 13950:2014 | GYPSUM BOARD THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
I.S. EN 12209:2016 | BUILDING HARDWARE - MECHANICALLY OPERATED LOCKS AND LOCKING PLATES - REQUIREMENTS AND TEST METHODS |
I.S. EN 303-5:2012 | HEATING BOILERS - PART 5: HEATING BOILERS FOR SOLID FUELS, MANUALLY AND AUTOMATICALLY STOKED, NOMINAL HEAT OUTPUT OF UP TO 500 KW - TERMINOLOGY, REQUIREMENTS, TESTING AND MARKING |
I.S. EN 1125:2008 | BUILDING HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
I.S. EN 13964:2014 | SUSPENDED CEILINGS - REQUIREMENTS AND TEST METHODS |
DIN EN 13069:2005-12 | Chimneys - Clay/ceramic outer walls for system chimneys - Requirements and test methods |
I.S. EN 12859:2011 | GYPSUM BLOCKS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
I.S. EN 14600:2005 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
DIN EN 15269-7:2010-04 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 7: Fire resistance for steel sliding doorsets |
I.S. EN 14190:2014 | GYPSUM BOARD PRODUCTS FROM REPROCESSING - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
I.S. EN 1366-3:2009 | FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS |
EN 16351:2015 | Timber structures - Cross laminated timber - Requirements |
VDI 2050 Blatt 1.1:2017-07 | Requirements for technical equipment rooms - Space for service shafts |
VDI 3564 Blatt 1:2017-05 | Fire protection - Recommendations for high-bay warehouses |
UNE-EN 1634-1:2016 | Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows |
EN 1279-5:2005+A2:2010 | Glass in building - Insulating glass units - Part 5: Evaluation of conformity |
09/30194124 DC : DRAFT MAY 2009 | BS EN 15254-7 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 7: NON-LOAD BEARING SANDWICH PANELS - CEILINGS |
BS EN 15287-2:2008 | Chimneys. Design, installation and commissioning of chimneys Chimneys for roomsealed appliances |
10/30216690 DC : 0 | BS EN 45545-3 - RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 3: FIRE RESISTANCE REQUIREMENTS FOR FIRE BARRIERS |
05/30134012 DC : 0 | EN 15254-4 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTION |
BS EN 50518-1:2013 | Monitoring and alarm receiving centre Location and construction requirements |
PREN 1125 : DRAFT 2016 | BUILD HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
16/30340523 DC : 0 | BS EN 17020-4 - EXTENDED APPLICATION OF TEST RESULTS ON DURABILITY OF SELFCLOSING FOR DOORSETS AND OPENABLE WINDOWS - PART 4: DURABILITY OF SELF-CLOSING OF FIRE RESISTANCE HINGED AND PIVOTED METAL FRAMED GLAZED DOORSETS AND OPENABLE WINDOWS |
DIN EN 15269-10:2011-07 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies including their elements of building hardware - Part 10: Fire resistance of steel rolling shutter assemblies |
16/30332911 DC : 0 | BS EN 14496 - GYPSUM BASED ADHESIVES FOR THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS AND GYPSUM BOARDS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
PD CEN/TR 14819-2:2005 | Safety recommendations for cableway installations designed to carry persons. Prevention and fight against fire Other funicular railways and other installations |
16/30347446 DC : 0 | BS EN 17064 - SAFETY REQUIREMENTS FOR CABLEWAY INSTALLATIONS DESIGNED TO CARRY PERSONS - PREVENTION AND FIGHT AGAINST FIRE |
10/30211853 DC : 0 | BS EN 16035 - HARDWARE PERFORMANCE SHEET (HPS) - IDENTIFICATION AND SUMMARY OF TEST EVIDENCE TO FACILITATE THE INTERCHANGEABILITY OF BUILDING HARDWARE FOR APPLICATION TO FIRE RESISTING AND SMOKE CONTROL DOORSETS AND OPENABLE WINDOWS |
I.S. EN 15080-8:2009 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - PART 8: BEAMS |
BS EN 15254-2:2009 | Extended application of results from fire resistance tests. Nonloadbearing walls Masonry and gypsum blocks |
BS EN 16240:2013 | Light transmitting flat solid polycarbonate (PC) sheets for internal and external use in roofs, walls and ceilings. Requirements and test methods |
BS EN 15269-7:2009 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware Fire resistance for steel sliding doorsets |
BS EN 15497:2014 | Structural finger jointed solid timber. Performance requirements and minimum production requirements |
UNE-EN 15681-2:2017 | Glass in Building - Basic alumino silicate glass products - Part 2: Product standard |
05/30137949 DC : 0 | EN 15269-3 - EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE FOR DOORSETS AND SHUTTER ASSEMBLIES - FOR DOORS AND SHUTTERS - PART 3: TIMBER HINGED AND PIVOTED DOORSETS |
BS EN 15254-5:2009 | Extended application of results from fire resistance tests. Non-loadbearing walls Metal sandwich panel construction |
16/30332908 DC : 0 | BS EN 14209 - PREFORMED PLASTERBOARD CORNICES - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
PD CEN/TR 15123:2005 | Design, preparation and application of internal polymer plastering systems |
BS EN 16035:2012 | Hardware performance sheet (HPS). Identification and summary of test evidence to facilitate the inter-changeability of building hardware for application to fire resisting and/or smoke control doorsets and/or openable windows |
DIN EN 15283-1:2009-12 | Gypsum boards with fibrous reinforcement - Definitions, requirements and test methods - Part 1: Gypsum boards with mat reinforcement (includes Amendment A1:2009) |
BS EN 15683-2:2013 | Glass in building. Thermally toughened soda lime silicate channel shaped safety glass Evaluation of conformity. Product standard |
BS EN 13200-7:2014 | Spectator facilities Entry and exit elements and routes |
BS EN 15882-3:2009 | Extended applications of results from fire resistance tests for service installations Penetration seals |
DIN EN 15498:2008-08 | PRECAST CONCRETE PRODUCTS - WOOD-CHIP CONCRETE SHUTTERING BLOCKS - PRODUCT PROPERTIES AND PERFORMANCE |
BS EN 15269-20:2009 | Extended application of test results for fire resistance and/ or smoke control for door, shutter and openable window assemblies, including their elements of building hardware Smoke control for hinged and pivoted steel, timber and metal framed glazed doorsets |
UNE-EN 50583-2:2016 | Photovoltaics in buildings - Part 2: BIPV systems |
BS EN 15725:2010 | Extended application reports on the fire performance of construction products and building elements |
DIN EN 13200-7 E : 2014 | SPECTATOR FACILITIES - PART 7: ENTRY AND EXIT ELEMENTS AND ROUTES |
UNI EN 303-5 : 2012 | HEATING BOILERS - PART 5: HEATING BOILERS FOR SOLID FUELS, MANUALLY AND AUTOMATICALLY STOKED, NOMINAL HEAT OUTPUT OF UP TO 500 KW - TERMINOLOGY, REQUIREMENTS, TESTING AND MARKING |
03/115046 DC : DRAFT SEP 2003 | BS EN 1366-4 - FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 4: LINEAR JOINT SEALS |
12/30266506 DC : 0 | BS EN 50583 - PHOTOVOLTAICS IN BUILDINGS |
UNE-EN 15998:2011 | Glass in building - Safety in case of fire, fire resistance - Glass testing methodology for the purpose of classification |
16/30347433 DC : 0 | BS EN 15254-4 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
DIN EN 13200-7:2014-06 | SPECTATOR FACILITIES - PART 7: ENTRY AND EXIT ELEMENTS AND ROUTES |
05/30136031 DC : 0 | EN 15287-1 - CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOMSEALED HEATING APPLIANCES |
BS EN 45545-3:2013 | Railway applications. Fire protection on railway vehicles Fire resistance requirements for fire barriers |
05/30138009 DC : DRAFT AUG 2005 | EN 15319 - GENERAL PRINCIPLES OF DESIGN OF FIBROUS (GYPSUM) PLASTER WORKS |
BS EN 15287-1 : 2007 | CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOMSEALED HEATING APPLIANCES |
DIN EN 15080-12:2011-04 | Extended application of results from fire resistance tests - Part 12: Loadbearing masonry walls |
10/30228886 DC : 0 | BS EN 303-5 - CENTRAL-HEATING BOILERS - PART 5: HEATING BOILERS FOR SOLID FUELS, HAND AND AUTOMATICALLY STOKED, NOMINAL HEAT OUTPUT OF UP TO 500 KW - TERMINOLOGY, REQUIREMENTS, TESTING AND MARKING |
DIN EN 14963:2006-12 | Roof coverings - Continuous rooflights of plastics with or without upstands - Classification, requirements and test methods; German version EN 14963:2006 |
11/30238648 DC : DRAFT FEB 2011 | BS EN 16240 - LIGHT TRANSMITTING FLAT SOLID POLYCARBONATE (PC) SHEETS FOR INTERNAL AND EXTERNAL ROOFS, WALLS AND CEILINGS - REQUIREMENTS AND TEST METHODS |
PREN 15269-20 : DRAFT 2017 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 20: SMOKE CONTROL FOR DOORS, SHUTTERS AND OPENABLE WINDOWS |
BS EN 15498:2008 | Precast concrete products. Wood-chip concrete shuttering blocks. Product properties and performance |
12/30274727 DC : 0 | BS EN 61936-1 AMD 1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
I.S. EN 15254-7:2012 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING CEILINGS - PART 7: METAL SANDWICH PANEL CONSTRUCTION |
DIN EN 16153:2015-05 | LIGHT TRANSMITTING FLAT MULTIWALL POLYCARBONATE (PC) SHEETS FOR INTERNAL AND EXTERNAL USE IN ROOFS, WALLS AND CEILINGS - REQUIREMENTS AND TEST METHODS |
PREN 50518 : DRAFT 2016 | MONITORING AND ALARM RECEIVING CENTRE |
I.S. CEN TR 14819-1:2004 | SAFETY RECOMMENDATIONS FOR CABLEWAY INSTALLATIONS DESIGNED TO CARRY PERSONS - PREVENTION AND FIGHT AGAINST FIRE - PART 1: FUNICULAR RAILWAYS IN TUNNELS |
PREN 14209 : DRAFT 2016 | PREFORMED PLASTERBOARD CORNICES - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
I.S. CEN/TR 15123:2005 | DESIGN, PREPARATION AND APPLICATION OF INTERNAL POLYMER PLASTERING SYSTEMS |
I.S. EN 50518-1:2013 | MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS |
PREN 15254-7 : DRAFT 2016 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING CEILINGS - PART 7: METAL SANDWICH PANEL CONSTRUCTION |
BS EN 1634-1 : 2014 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 1: FIRE RESISTANCE TEST FOR DOOR AND SHUTTER ASSEMBLIES AND OPENABLE WINDOWS |
I.S. EN 16240:2013 | LIGHT TRANSMITTING FLAT SOLID POLYCARBONATE (PC) SHEETS FOR INTERNAL AND EXTERNAL USE IN ROOFS, WALLS AND CEILINGS - REQUIREMENTS AND TEST METHODS |
UNI EN 13200-7 : 2014 | SPECTATOR FACILITIES - PART 7: ENTRY AND EXIT ELEMENTS AND ROUTES |
UNI EN 15254-6 : 2014 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 6: CURTAIN WALLING |
I.S. EN 15269-3:2012 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 3: FIRE RESISTANCE OF HINGED AND PIVOTED TIMBER DOORSETS AND OPENABLE |
I.S. EN 15725:2010 | EXTENDED APPLICATION REPORTS ON THE FIRE PERFORMANCE OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS |
ISO/TS 20100:2008 | Gaseous hydrogen Fuelling stations |
PREN 14190 : DRAFT 2011 | GYPSUM PLASTERBOARD PRODUCTS FROM PROCESSING - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
DIN EN 13369:2013-08 | COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
NF EN 1279-5 : 2005 + A2 2010 | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY |
UNE-EN 15254-6:2015 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 6: Curtain walling |
PREN 14509 : DRAFT 2013 | SELF-SUPPORTING DOUBLE SKIN METAL FACED INSULATING PANELS - FACTORY MADE PRODUCTS - SPECIFICATIONS |
I.S. EN 1634-2:2008 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES AND ELEMENTS OF BUILDING HARDWARE - PART 2: FIRE RESISTANCE CHARACTERISATION TEST FOR ELEMENTS OF BUILDING HARDWARE |
UNE-EN 15269-3:2016 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 3: Fire resistance of hinged and pivoted timber doorsets and openable timber framed windows |
PREN 1279-5 : DRAFT 2015 | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY |
BS EN 1096-4:2004 | Glass in building. Coated glass Evaluation of conformity/Product standard |
PREN 179 : DRAFT 2016 | BUILDING HARDWARE - EMERGENCY EXIT DEVICES OPERATED BY A LEVER HANDLE OR PUSH PAD, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
UNI EN 15254-2 : 2009 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 2: MASONRY AND GYPSUM BLOCKS |
UNI EN 15498 : 2008 | PRECAST CONCRETE PRODUCTS - WOOD-CHIP CONCRETE SHUTTERING BLOCKS - PRODUCT PROPERTIES AND PERFORMANCE |
UNI EN 16035 : 2013 | HARDWARE PERFORMANCE SHEET (HPS) - IDENTIFICATION AND SUMMARY OF TEST EVIDENCE TO FACILITATE THE INTER-CHANGEABILITY OF BUILDING HARDWARE FOR APPLICATION TO FIRE RESISTING AND/OR SMOKE CONTROL DOORSETS AND/OR OPENABLE WINDOWS |
I.S. CEN TR 14819-2:2006 | SAFETY RECOMMENDATIONS FOR CABLEWAY INSTALLATIONS DESIGNED TO CARRY PERSONS - PREVENTION AND FIGHT AGAINST FIRE - PART 2: OTHER FUNICULAR RAILWAYS AND OTHER INSTALLATIONS |
UNE-EN 16034:2015 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
PREN 1443 : DRAFT 2017 | CHIMNEYS - GENERAL REQUIREMENTS |
UNE-EN 15269-5:2016 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 5: Fire resistance of hinged and pivoted metal framed glazed doorsets and openable windows |
PREN 13950 : DRAFT 2011 | GYPSUM BOARD THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
PREN 13915 : DRAFT 2016 | PREFABRICATED GYPSUM PLASTERBOARD PANELS WITH A CELLULAR PAPERBOARD CORE - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
UNI CEI EN 45545-3 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 3: FIRE RESISTANCE REQUIREMENTS FOR FIRE BARRIERS |
PREN 81-58 : DRAFT 2016 | SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - EXAMINATION AND TESTS - PART 58: LANDING DOORS FIRE RESISTANCE TEST |
EN 61936-1 : 2010 AMD 1 2014 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014) |
EN 1634-1:2014 | Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows |
EN 15269-11:2018 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 11: Fire resistance for operable fabric curtains |
I.S. EN 14509:2013 | SELF-SUPPORTING DOUBLE SKIN METAL FACED INSULATING PANELS - FACTORY MADE PRODUCTS - SPECIFICATIONS |
I.S. EN 1279-5:2005 | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY |
I.S. EN 15498:2008 | PRECAST CONCRETE PRODUCTS - WOOD-CHIP CONCRETE SHUTTERING BLOCKS - PRODUCT PROPERTIES AND PERFORMANCE |
DIN EN 14179-2:2005-08 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
DIN EN 12150-2:2005-01 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard; German version EN 12150-2:2004 |
DIN EN 12859:2011-05 | Gypsum blocks - Definitions, requirements and test methods |
DIN EN 1366-7:2004-09 | Fire resistance tests for service installations - Part 7: Conveyor systems and their closures |
DIN EN 1863-2:2005-01 | Glass in building - Heat strengthened soda lime silicate glass - Part 2: Evaluation of conformity/Product standard; German version EN 1863-2:2004 |
DIN EN 1125:2008-04 | BUILDING HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
DIN EN 13024-2:2005-01 | Glass in building - Thermally toughened borosilicate safety glass - Part 2: Evaluation of conformity/Product standard; German version EN 13024-2:2004 |
DIN EN 438-7:2005-04 | High-pressure decorative laminates (HPL) - Sheets based on thermosetting resins (usually called laminates) - Part 7: Compact laminate and HPL composite panels for internal and external wall and ceiling finishes; German version EN 438-7:2005 |
DIN EN 13950:2014-09 | GYPSUM BOARD THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
DIN EN 13915:2016-02 (Draft) | PREFABRICATED GYPSUM PLASTERBOARD PANELS WITH A CELLULAR PAPERBOARD CORE - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
DIN EN 13964:2014-08 | SUSPENDED CEILINGS - REQUIREMENTS AND TEST METHODS |
UNE-EN 14509:2014 | Self-supporting double skin metal faced insulating panels - Factory made products - Specifications |
BS EN 1125:2008 | Building hardware. Panic exit devices operated by a horizontal bar, for use on escape routes. Requirements and test methods |
BS EN 14178-2:2004 | Glass in building. Basic alkaline earth silicate glass products Evaluation of conformity/Product standard |
BS EN 14600:2005 | Doorsets and openable windows with fire resisting and/ or smoke control characteristics. Requirements and classification |
BS EN 1520:2011 | Prefabricated reinforced components of lightweight aggregate concrete with open structure with structural or non-structural reinforcement |
UNE-EN 14250:2010 | Timber structures - Product requirements for prefabricated structural members assembled with punched metal plate fasteners |
BS EN 572-9:2004 | Glass in building. Basic soda lime silicate glass products Evaluation of conformity/Product standard |
BS EN 13069:2005 | Chimneys. Clay/ceramic outer walls for system chimneys. Requirements and test methods |
UNE-EN 13830:2016 | Curtain walling - Product standard |
18/30359998 DC : 0 | BS ISO 19880-1 - GASEOUS HYDROGEN - FUELLING STATIONS - PART 1: GENERAL REQUIREMENTS |
I.S. EN 14080:2013 | TIMBER STRUCTURES - GLUED LAMINATED TIMBER AND GLUED SOLID TIMBER - REQUIREMENTS |
EN 13830:2015 | Curtain walling - Product standard |
UNE-EN 15269-1:2011 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 1: General requirements |
UNE-EN 12859:2012 | Gypsum blocks - Definitions, requirements and test methods |
EN 15269-20:2009 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 20: Smoke control for hinged and pivoted steel, timber and metal framed glazed doorsets |
EN 15998:2010 | Glass in building - Safety in case of fire, fire resistance - Glass testing methodology for the purpose of classification |
EN 15283-1:2008+A1:2009 | Gypsum boards with fibrous reinforcement - Definitions, requirements and test methods - Part 1: Gypsum boards with mat reinforcement |
EN 13964:2014 | Suspended ceilings - Requirements and test methods |
EN 16240:2013 | Light transmitting flat solid polycarbonate (PC) sheets for internal and external use in roofs, walls and ceilings - Requirements and test methods |
UNI EN 12859 : 2011 | GYPSUM BLOCKS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
UNI EN 14509 : 2013 | SELF-SUPPORTING DOUBLE SKIN METAL FACED INSULATING PANELS - FACTORY MADE PRODUCTS - SPECIFICATIONS |
UNI EN 520 : 2009 | GYPSUM PLASTERBOARDS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
EN 15681-2:2017 | Glass in Building - Basic alumino silicate glass products - Part 2: Product standard |
UNI EN 14600 : 2006 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
EN 1125:2008 | Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods |
UNI EN 14449 : 2005 | GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - EVALUATION OF CONFORMITY/PRODUCT STANDARD |
UNI EN 1520 : 2011 | Prefabricated reinforced components of lightweight aggregate concrete with open structure with structural or non- structural reinforcement |
UNI EN 14080 : 2013 | TIMBER STRUCTURES - GLUED LAMINATED TIMBER AND GLUED SOLID TIMBER - REQUIREMENTS |
UNI EN 1993-1-2 : 2005 | EUROCODE 3 - DESIGN OF STEEL STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN |
UNI EN 1634-3 : 2005 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 3: SMOKE CONTROL TEST FOR DOOR AND SHUTTER ASSEMBLIES |
UNI EN 14190 : 2014 | GYPSUM BOARD PRODUCTS FROM REPROCESSING - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
UNI EN 13964 : 2014 | SUSPENDED CEILINGS - REQUIREMENTS AND TEST METHODS |
UNI EN 14250 : 2010 | TIMBER STRUCTURES - PRODUCT REQUIREMENTS FOR PREFABRICATED STRUCTURAL MEMBERS ASSEMBLED WITH PUNCHED METAL PLATE FASTENERS |
ONORM EN 1366-3 : 2009 | FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS |
UNI EN 1364-3 : 2014 | FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 3: CURTAIN WALLING - FULL CONFIGURATION (COMPLETE ASSEMBLY) |
UNI EN 1999-1-2 : 2007 | EUROCODE 9 - DESIGN OF ALUMINIUM STRUCTURES - PART 1-2: STRUCTURAL FIRE DESIGN |
UNI EN 14246 : 2006 | GYPSUM ELEMENTS FOR SUSPENDED CEILINGS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
UNI EN 13279-1 : 2008 | GYPSUM BINDERS AND GYPSUM PLASTERS - PART 1: DEFINITIONS AND REQUIREMENTS |
UNI EN 13950 : 2014 | GYPSUM BOARD THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
UNI EN 1364-4 : 2014 | FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 4: CURTAIN WALLING - PART CONFIGURATION |
UNI EN 179 : 2008 | BUILDING HARDWARE - EMERGENCY EXIT DEVICES OPERATED BY A LEVER HANDLE OR PUSH PAD, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
UNI EN 1125 : 2008 | BUILDING HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
UNE-EN 50223:2016 | Stationary electrostatic application equipment for ignitable flock material - Safety requirements |
DIN EN 15683-2:2014-02 | GLASS IN BUILDING - THERMALLY TOUGHENED SODA LIME SILICATE CHANNEL SHAPED SAFETY GLASS - PART 2: EVALUATION OF CONFORMITY/PRODUCT STANDARD |
17/30357430 DC | BS EN 13658-2. Metal lath and beads. Definitions, requirements and test methods. Part 2. External rendering |
UNI EN 15725 : 2010 | EXTENDED APPLICATION REPORTS ON THE FIRE PERFORMANCE OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS |
04/30111056 DC : DRAFT MARCH 2004 | EN 1806 - CHIMNEYS - CLAY/CERAMIC FLUE BLOCKS FOR SINGLE WALL CHIMNEYS - REQUIREMENTS AND TEST METHODS |
EN 303-5:2012 | Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking |
DIN EN 16351:2015-12 | Timber structures - Cross laminated timber - Requirements |
I.S. EN 15497:2014 | STRUCTURAL FINGER JOINTED SOLID TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
UNE-EN 13915:2018 | Prefabricated gypsum plasterboard panels with a cellular paperboard core - Definitions, requirements and test methods |
11/30249114 DC : 0 | BS EN 15497 - STRUCTURAL FINGER JOINTED SOLID TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
DIN EN 16309:2014-12 | SUSTAINABILITY OF CONSTRUCTION WORKS - ASSESSMENT OF SOCIAL PERFORMANCE OF BUILDINGS - CALCULATION METHODOLOGY |
I.S. EN 15269-11:2018+AC:2019 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 11: FIRE RESISTANCE FOR OPERABLE FABRIC CURTAINS |
BS EN 15080-8:2009 | Extended application of results from fire resistance tests Beams |
UNI CEI CEN/TS 45545-3 : 2009 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 3: FIRE RESISTANCE REQUIREMENTS FOR FIRE BARRIERS |
DIN EN 16034:2014-12 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resistance and/or smoke control characteristics; German version EN 16034:2014 |
04/30124508 DC : 0 | EN 15080-12 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - PART 12: PENETRATION SEALS |
16/30330690 DC : 0 | BS EN 15254-7 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING CEILINGS - PART 7: METAL SANDWICH PANEL CONSTRUCTION |
PREN 13369 : DRAFT 2017 | COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
07/30172842 DC : 0 | BS EN 15080-12 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - PART 12: LOADBEARING MASONRY WALLS |
13/30263194 DC : 0 | BS EN 16623 - PAINTS AND VARNISHES - REACTIVE COATINGS FOR FIRE PROTECTION OF METALLIC SUBSTRATES - DEFINITIONS, REQUIREMENTS, CHARACTERISTICS AND MARKING |
CEN/TR 12101-4:2009 | Smoke and heat control systems - Part 4: Installed SHEVS systems for smoke and heat ventilation |
17/30360667 DC : DRAFT SEP 2017 | BS EN 1748-2-2 - GLASS IN BUILDING - SPECIAL BASIC PRODUCTS - GLASS CERAMICS - PART 2-2: PRODUCT STANDARD |
13/30288842 DC : 0 | BS EN 14081-1 - TIMBER STRUCTURES - STRENGTH GRADED STRUCTURAL TIMBER WITH RECTANGULAR CROSS SECTION - PART 1: GENERAL REQUIREMENTS |
DIN EN 15998:2011-02 | GLASS IN BUILDING - SAFETY IN CASE OF FIRE, FIRE RESISTANCE - GLASS TESTING METHODOLOGY FOR THE PURPOSE OF CLASSIFICATION |
BS EN 15269-3:2012 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware Fire resistance of hinged and pivoted timber doorsets and openable timber framed windows |
DIN EN 1634-2:2009-05 | FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES AND ELEMENTS OF BUILDING HARDWARE - PART 2: FIRE RESISTANCE CHARACTERISATION TEST FOR ELEMENTS OF BUILDING HARDWARE |
00/107014 DC : DRAFT OCT 2000 | PREN 520 - GYPSUM PLASTERBOARDS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
DIN EN 15080-8:2010-02 | Extended application of results from fire resistance tests - Part 8: Beams |
UNI EN 15080-8 : 2009 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - PART 8: BEAMS |
DIN EN 16240:2014-03 | LIGHT TRANSMITTING FLAT SOLID POLYCARBONATE (PC) SHEETS FOR INTERNAL AND EXTERNAL USE IN ROOFS, WALLS AND CEILINGS - REQUIREMENTS AND TEST METHODS |
17/30357433 DC | BS EN 13279-1. Gypsum binders and gypsum plasters. Part 1. Definitions and requirements |
I.S. EN 16351:2015 | TIMBER STRUCTURES - CROSS LAMINATED TIMBER - REQUIREMENTS |
PREN 14496 : DRAFT 2016 | GYPSUM BASED ADHESIVES FOR THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS AND GYPSUM BOARDS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
PREN 50583 : DRAFT 2012 | PHOTOVOLTAICS IN BUILDINGS |
UNE-EN 13369:2013 | Common rules for precast concrete products |
BS EN 15998:2010 | Glass in building. Safety in case of fire, fire resistance. Glass testing methodology for the purpose of classification |
11/30252455 DC : 0 | BS EN 1364-4 - FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 4: CURTAIN WALLING - PART CONFIGURATION |
05/30135869 DC : 0 | EN 15283-1 - GYPSUM BOARDS WITH FIBROUS REINFORCEMENT - DEFINITIONS, REQUIREMENTS AND TEST METHODS - PART 1: GYPSUM BOARDS WITH MAT REINFORCEMENT |
11/30252458 DC : 0 | BS EN 1364-3 - FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 3: CURTAIN WALLING - FULL CONFIGURATION (COMPLETE ASSEMBLY) |
I.S. EN 1090-1:2009 | EXECUTION OF STEEL STRUCTURES AND ALUMINIUM STRUCTURES - PART 1: REQUIREMENTS FOR CONFORMITY ASSESSMENT OF STRUCTURAL COMPONENTS |
I.S. EN 1999-1-2:2007 | EUROCODE 9 - DESIGN OF ALUMINIUM STRUCTURES - PART 1-2: STRUCTURAL FIRE DESIGN (INCLUDING IRISH NATIONAL ANNEX) |
UNI EN 15882-3 : 2009 | EXTENDED APPLICATIONS OF RESULTS FROM FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS |
17/30357427 DC | BS EN 13658-1. Metal lath and beads. Definitions, requirements and test methods. Part 1. Internal plastering |
BS EN 12602:2016 | Prefabricated reinforced components of autoclaved aerated concrete |
UNI EN 15882-4 : 2012 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 4: LINEAR JOINT SEALS |
I.S. CEN/TR 15124:2005 | DESIGN, PREPARATION AND APPLICATION OF INTERNAL GYPSUM PLASTERING SYSTEMS |
PREN 14179-2 : DRAFT 2017 | GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED SODA LIME SILICATE SAFETY GLASS - PART 2: PRODUCT STANDARD |
I.S. EN 15254-6:2014 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 6: CURTAIN WALLING |
XP CEN/TS 45545-3 : 2009 XP | RAILWAY APPLICATIONS - FIRE PROTECTION OF RAILWAY VEHICLES - PART 3: FIRE RESISTANCE REQUIREMENTS FOR FIRE BARRIERS |
BS EN 15254-7:2012 | Extended application of results from fire resistance tests. Non-loadbearing ceilings Metal sandwich panel construction |
I.S. EN 15683-2:2013 | GLASS IN BUILDING - THERMALLY TOUGHENED SODA LIME SILICATE CHANNEL SHAPED SAFETY GLASS - PART 2: EVALUATION OF CONFORMITY/PRODUCT STANDARD |
I.S. EN 15287-2:2008 | CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 2: CHIMNEYS FOR ROOMSEALED APPLIANCES |
I.S. EN 15882-4:2012 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 4: LINEAR JOINT SEALS |
S.R. CEN/TS 45545-3:2009 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 3: FIRE RESISTANCE REQUIREMENTS FOR FIRE BARRIERS |
PREN 845-2 : DRAFT 2012 | SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 2: LINTELS |
EN 81-58:2018 | Safety rules for the construction and installation of lifts - Examination and tests - Part 58: Landing doors fire resistance test |
15/30324901 DC : 0 | BS EN 1504-3 - PRODUCTS AND SYSTEMS FOR THE PROTECTION AND REPAIR OF CONCRETE STRUCTURES - DEFINITIONS, REQUIREMENTS, QUALITY CONTROL AND AVCP - PART 3: REPAIR CONCRETE AND MORTARS |
16/30343246 DC : 0 | BS EN 1125 - BUILDING HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
UNI EN 15254-7 : 2012 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING CEILINGS - PART 7: METAL SANDWICH PANEL CONSTRUCTION |
15/30327624 DC : 0 | BS EN 15269-6 - EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 6: FIRE RESISTANCE OF SLIDING TIMBER DOORSETS |
PREN 15254-5 : DRAFT 2016 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 5: METAL SANDWICH PANEL CONSTRUCTION |
PREN 12859 : DRAFT 2010 | GYPSUM BLOCKS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
EN 15254-7:2018 | Extended application of results from fire resistance tests - Non-loadbearing ceilings - Part 7: Metal sandwich panel construction |
I.S. EN 61936-1:2010 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
EN 13369:2018 | Common rules for precast concrete products |
I.S. CEN TR 12101-4:2006 | SMOKE AND HEAT CONTROL SYSTEMS - PART 4: INSTALLED SHEVS SYSTEMS FOR SMOKE AND HEAT VENTILATION |
I.S. EN 15882-3:2009 | EXTENDED APPLICATIONS OF RESULTS FROM FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS |
I.S. EN 81-58:2018 | SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - EXAMINATION AND TESTS - PART 58: LANDING DOORS FIRE RESISTANCE TEST |
I.S. EN 13279-1:2008 | GYPSUM BINDERS AND GYPSUM PLASTERS - PART 1: DEFINITIONS AND REQUIREMENTS |
DIN EN 14209:2016-02 (Draft) | PREFORMED PLASTERBOARD CORNICES - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
DIN EN 14190:2014-09 | Gypsum board products from reprocessing - Definitions, requirements and test methods |
DIN EN 14081-1:2016-06 | TIMBER STRUCTURES - STRENGTH GRADED STRUCTURAL TIMBER WITH RECTANGULAR CROSS SECTION - PART 1: GENERAL REQUIREMENTS |
DIN EN 14080:2013-09 | TIMBER STRUCTURES - GLUED LAMINATED TIMBER AND GLUED SOLID TIMBER - REQUIREMENTS |
DIN EN 1634-3:2005-01 | Fire resistance tests for door and shutter assemblies - Part 3: Smoke control doors and shutters |
BS EN 1863-2:2004 | Glass in building. Heat strengthened soda lime silicate glass Evaluation of conformity. Product standard |
BS EN 13658-1:2005 | Metal lath and beads. Definitions, requirements and test methods Internal plastering |
BS EN 13950:2014 | Gypsum board thermal/acoustic insulation composite panels. Definitions, requirements and test methods |
BS EN 13915:2017 | Prefabricated gypsum plasterboard panels with a cellular paperboard core. Definitions, requirements and test methods |
BS EN 13815:2006 | Fibrous gypsum plaster casts. Definitions, requirements and test methods |
BS EN 14209:2017 | Preformed plasterboard cornices. Definitions, requirements and test methods |
EN 15269-1:2010 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 1: General requirements |
BS EN 1364-4:2014 | Fire resistance tests for non-loadbearing elements Curtain walling. Part configuration |
UNE-EN 16351:2016 | Timber structures - Cross laminated timber - Requirements |
BS EN 1366-3:2009 | Fire resistance tests for service installations Penetration seals |
UNE-EN 1366-3:2011 | Fire resistance tests for service installations - Part 3: Penetration seals |
11/30211394 DC : DRAFT MAR 2011 | BS ISO 20100 - GASEOUS HYDROGEN - FUELLING STATIONS |
UNE-EN 14081-1:2016 | Timber structures - Strength graded structural timber with rectangular cross section - Part 1: General requirements |
DIN EN 15319:2007-10 | General principles of design of fibrous (gypsum) plaster works |
UNE-EN 14190:2014 | Gypsum board products from reprocessing - Definitions, requirements and test methods |
BS EN 13063-1:2005 | Chimneys. System chimneys with clay/ceramic flue liners Requirements and test methods for sootfire resistance |
UNE-EN 12209:2017 | Building hardware - Mechanically operated locks and locking plates - Requirements and test methods |
UNE EN 15287-1 : 0 | CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOMSEALED HEATING APPLIANCES |
BS EN 13279-1:2008 | Gypsum binders and gypsum plasters Definitions and requirements |
BS EN 14321-2:2005 | Glass in building. Thermally toughened alkaline earth silicate safety glass Evaluation of conformity/Product standard |
BS EN 15318:2007 | Design and application of gypsum blocks |
BS EN 14250:2010 | Timber structures. Product requirements for prefabricated structural members assembled with punched metal plate fasteners |
UNE EN 16309 : 0 | SUSTAINABILITY OF CONSTRUCTION WORKS - ASSESSMENT OF SOCIAL PERFORMANCE OF BUILDINGS - CALCULATION METHODOLOGY |
17/30326406 DC : 0 | BS EN 17168 - RAILWAY APPLICATIONS - PLATFORM BARRIER SYSTEMS |
BS EN 61936-1 : 2010 | POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES |
BS EN 1364-3:2014 | Fire resistance tests for non-loadbearing elements Curtain walling. Full configuration (complete assembly) |
BS EN 12391-1:2003 | Chimneys. Execution standard for metal chimneys Chimneys for non-roomsealed heating appliances |
BS EN 14246:2006 | Gypsum elements for suspended ceilings. Definitions, requirements and test methods |
BS EN 13830:2015 | Curtain walling. Product standard |
UNE-EN 520:2005 | Gypsum plasterboards - Definitions, requirements and test methods |
BS EN 1748-1-2:2004 | Glass in building. Special basic products Borosilicate glasses - Evaluation of conformity. Product standard |
BS EN 14080:2013 | Timber structures. Glued laminated timber and glued solid timber. Requirements |
UNE-EN 1364-4:2015 | Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration |
BS EN 14449:2005 | Glass in building. Laminated glass and laminated safety glass. Evaluation of conformity/product standard |
BS EN 12859:2011 | Gypsum blocks. Definitions, requirements and test methods |
UNE-EN 14209:2017 | Preformed plasterboard cornices - Definitions, requirements and test methods |
BS EN 1748-2-2:2004 | Glass in building. Special basic products Glass ceramics - Evaluation of conformity/Product standard |
EN 14190:2014 | Gypsum board products from reprocessing - Definitions, requirements and test methods |
EN 15269-10:2011 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies including their elements of building hardware - Part 10: Fire resistance of steel rolling shutter assemblies |
EN 15882-4:2012 | Extended application of results from fire resistance tests for service installations - Part 4: Linear joint seals |
EN 13950:2014 | Gypsum board thermal/acoustic insulation composite panels - Definitions, requirements and test methods |
EN 845-2:2013+A1:2016 | Specification for ancillary components for masonry - Part 2: Lintels |
EN 15269-3:2012 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 3: Fire resistance of hinged and pivoted timber doorsets and openable timber framed windows |
EN 15283-2:2008+A1:2009 | Gypsum boards with fibrous reinforcement - Definitions, requirements and test methods - Part 2: Gypsum fibre boards |
EN 14080:2013 | Timber structures - Glued laminated timber and glued solid timber - Requirements |
EN 15269-5:2014+A1:2016 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 5: Fire resistance of hinged and pivoted metal framed glazed doorsets and openable windows |
EN 16153:2013+A1:2015 | Light transmitting flat multiwall polycarbonate (PC) sheets for internal and external use in roofs, walls and ceilings - Requirements and test methods |
EN 14471:2013+A1:2015 | Chimneys - System chimneys with plastic flue liners - Requirements and test methods |
EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
EN 14963:2006 | Roof coverings - Continuous rooflights of plastics with or without upstands - Classification, requirements and test methods |
EN 13658-2:2005 | Metal lath and beads - Definitions, requirements and test methods - Part 2: External rendering |
UNI EN 1366-3 : 2009 | FIRE RESISTANCE TESTS FOR SERVICE INSTALLATIONS - PART 3: PENETRATION SEALS |
EN 14178-2:2004 | Glass in building - Basic alkaline earth silicate glass products - Part 2: Evaluation of conformity/Product standard |
EN 520:2004+A1:2009 | Gypsum plasterboards - Definitions, requirements and test methods |
EN 15498:2008 | Precast concrete products - Wood-chip concrete shuttering blocks - Product properties and performance |
EN 15254-6:2014 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 6: Curtain walling |
EN 14321-2:2005 | Glass in building - Thermally toughened alkaline earth silicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 15683-2:2013 | Glass in building - Thermally toughened soda lime silicate channel shaped safety glass - Part 2: Evaluation of conformity/Product standard |
EN 14989-1:2007 | Chimneys - Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications - Part 1: Vertical air/flue terminals for C6-type appliances |
EN 15287-2:2008 | Chimneys - Design, installation and commissioning of chimneys - Part 2: Chimneys for roomsealed appliances |
EN 13815:2006 | Fibrous gypsum plaster casts - Definitions, requirements and test methods |
EN 1748-1-2:2004 | Glass in building - Special basic products - Borosilicate glasses - Part 1-2: Evaluation of conformity/Product standard |
EN 14509:2013 | Self-supporting double skin metal faced insulating panels - Factory made products - Specifications |
EN 15318:2007 | Design and application of gypsum blocks |
EN 1364-3:2014 | Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration (complete assembly) |
EN 14600:2005 | Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification |
EN 14081-1:2016 | Timber structures - Strength graded structural timber with rectangular cross section - Part 1: General requirements |
EN 16309:2014+A1:2014 | Sustainability of construction works - Assessment of social performance of buildings - Calculation methodology |
EN 13915:2017 | Prefabricated gypsum plasterboard panels with a cellular paperboard core - Definitions, requirements and test methods |
EN 14209:2017 | Preformed plasterboard cornices - Definitions, requirements and test methods |
EN 1520:2011 | Prefabricated reinforced components of lightweight aggregate concrete with open structure with structural or non-structural reinforcement |
EN 1748-2-2:2004 | Glass in building - Special basic products - Part 2-2: Glass ceramics - Evaluation of conformity/Product standard |
EN 16623:2015 | Paints and varnishes - Reactive coatings for fire protection of metallic substrates - Definitions, requirements, characteristics and marking |
EN 15080-8:2009 | Extended application of results from fire resistance tests - Part 8: Beams |
EN 15254-2:2009 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 2: Masonry and Gypsum Blocks |
EN 179:2008 | Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods |
EN 1364-4:2014 | Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration |
EN 1634-2:2008 | Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware |
EN 15269-7:2009 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 7: Fire resistance for steel sliding doorsets |
EN 357:2004 | Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance |
EN 14496:2017 | Gypsum based adhesives for thermal/acoustic insulation composite panels and gypsum boards - Definitions, requirements and test methods |
EN 438-7:2005 | High-pressure decorative laminates (HPL) - Sheets based on thermosetting resins (Usually called Laminates) - Part 7: Compact laminate and HPL composite panels for internal and external wall and ceiling finishes |
EN 16035:2012 | Hardware performance sheet (HPS) - Identification and summary of test evidence to facilitate the inter-changeability of building hardware for application to fire resisting and/or smoke control doorsets and/or openable windows |
EN 15497:2014 | Structural finger jointed solid timber - Performance requirements and minimum production requirements |
EN 15682-2:2013 | Glass in building - Heat soaked thermally toughened alkaline earth silicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 15882-3:2009 | Extended applications of results from fire resistance tests for service installations - Part 3: Penetration seals |
EN 15269-2:2012 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 2: Fire resistance of hinged and pivoted steel doorsets |
EN 572-9:2004 | Glass in building - Basic soda lime silicate glass products - Part 9: Evaluation of conformity/Product standard |
EN 15080-12:2011 | Extended application of results from fire resistance tests - Part 12: Loadbearing masonry walls |
EN 1863-2:2004 | Glass in building - Heat strengthened soda lime silicate glass - Part 2: Evaluation of conformity/Product standard |
EN 15319:2007 | General principles of design of fibrous (gypsum) plaster works |
EN 13658-1:2005 | Metal lath and beads - Definitions, requirements and test methods - Part 1: Internal plastering |
EN 14179-2:2005 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 14620-4:2006 | Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Part 4: Insulation components |
EN 1364-5:2017 | Fire resistance tests for non-loadbearing elements - Part 5: Air transfer grilles |
I.S. EN 45545-1:2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 1: GENERAL |
ISO/TR 12470-1:2017 | Fire-resistance tests Guidance on the application and extension of results from tests conducted on fire containment assemblies and products Part 1: Loadbearing elements and vertical and horizontal separating elements |
DIN EN 16035:2013-03 | Hardware performance sheet (HPS) - Identification and summary of test evidence to facilitate the interchangeability of building hardware for application to fire resisting and/or smoke control doorsets and/or openable windows |
UNE-EN 15682-2:2014 | Glass in building - Heat soaked thermally toughened alkaline earth silicate safety glass - Part 2: Evaluation of conformity/Product standard |
BS EN 14963:2006 | Roof coverings. Continuous rooflights of plastics with or without upstands. Classification, requirements and test methods |
UNE-EN 50583-1:2016 | Photovoltaics in buildings - Part 1: BIPV modules |
05/30135872 DC : 0 | EN 15283-2 - GYPSUM BOARDS WITH FIBROUS REINFORCEMENT - DEFINITIONS, REQUIREMENTS AND TEST METHODS - PART 2: GYPSUM FIBRE BOARDS |
I.S. EN 438-7:2005 | HIGH-PRESSURE DECORATIVE LAMINATES (HPL) - SHEETS BASED ON THERMOSETTING RESINS (USUALLY CALLED LAMINATES) - PART 7: COMPACT LAMINATE AND HPL COMPOSITE PANELS FOR INTERNAL AND EXTERNAL WALL AND CEILING FINISHES |
UNE-EN 15497:2014 | Structural finger jointed solid timber - Performance requirements and minimum production requirements |
UNE-EN 15319:2012 | General principles of design of fibrous (gypsum) plaster works |
UNE-EN 15269-2:2016 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 2: Fire resistance of hinged and pivoted steel doorsets |
I.S. EN 15287-1:2007 | CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOMSEALED HEATING APPLIANCES |
I.S. EN 16623:2015 | PAINTS AND VARNISHES - REACTIVE COATINGS FOR FIRE PROTECTION OF METALLIC SUBSTRATES - DEFINITIONS, REQUIREMENTS, CHARACTERISTICS AND MARKING |
UNE-EN 1993-1-2:2016 | Eurocode 3: Design of steel structures - Part 1-2: General rules - Structural fire design |
DIN EN 45545-3:2013-08 | Railway applications - Fire protection on railway vehicles - Part 3: Fire resistance requirements for fire barriers; German version EN 45545-3:2013 |
I.S. EN 15269-2:2012 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 2: FIRE RESISTANCE OF HINGED AND PIVOTED STEEL DOORSETS |
17/30359844 DC : 0 | BS EN 572-9 - GLASS IN BUILDING - BASIC SODA LIME SILICATE GLASS PRODUCTS - PART 9: PRODUCT STANDARD |
05/30093062 DC : 0 | PREN 15269-2 - EXTENDED APPLICATION OF TEST RESULTS FOR DOORSETS AND SHUTTER ASSEMBLIES - FOR DOORS AND SHUTTERS - PART 2: STEEL HINGED AND PIVOTED DOORSETS |
BS EN 15283-2 : 2008 | GYPSUM BOARDS WITH FIBROUS REINFORCEMENT - DEFINITIONS, REQUIREMENTS AND TEST METHODS - PART 2: GYPSUM FIBRE BOARDS |
05/30137946 DC : 0 | EN 15269-1 - EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE FOR DOORSETS AND SHUTTER ASSEMBLIES - FOR DOORS AND SHUTTERS - PART 1: GENERAL REQUIREMENTS FOR FIRE RESISTANCE |
06/30154477 DC : 0 | EN 1634-2 - FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 2: FIRE RESISTANCE CHARACTERISATION TEST FOR ELEMENTS OF BUILDING HARDWARE |
BS EN 15080-12:2011 | Extended application of results from fire resistance tests Loadbearing masonry walls |
11/30251985 DC : 0 | BS EN 13950 - GYPSUM PLASTERBOARD THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
12/30265747 DC : 0 | BS EN 845-2 - SPECIFICATION FOR ANCILLARY COMPONENTS FOR MASONRY - PART 2: LINTELS |
BS EN 15269-5 : 2014 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 5: FIRE RESISTANCE OF HINGED AND PIVOTED METAL FRAMED GLAZED DOORSETS AND OPENABLE WINDOWS |
DIN EN 15269-3:2012-10 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 3: Fire resistance of hinged and pivoted timber doorsets and openable timber framed windows |
DIN EN 15497 E : 2014 | STRUCTURAL FINGER JOINTED SOLID TIMBER - PERFORMANCE REQUIREMENTS AND MINIMUM PRODUCTION REQUIREMENTS |
12/30255661 DC : 0 | BS EN 15269-5 - EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 5: FIRE RESISTANCE OF HINGED AND PIVOTED METAL FRAMED GLAZED DOORSETS AND OPENABLE WINDOWS |
PD ISO/TR 12470-2:2017 | Fire-resistance tests. Guidance on the application and extension of results from tests conducted on fire containment assemblies and products Non-loadbearing elements |
UNI EN 15683-2 : 2014 | GLASS IN BUILDING - THERMALLY TOUGHENED SODA LIME SILICATE CHANNEL SHAPED SAFETY GLASS - PART 2: EVALUATION OF CONFORMITY/PRODUCT STANDARD |
BS EN 15882-4:2012 | Extended application of results from fire resistance tests for service installations Linear joint seals |
I.S. EN 50583-2:2016 | PHOTOVOLTAICS IN BUILDINGS - PART 2: BIPV SYSTEMS |
12/30266553 DC : 0 | BS EN 16477-2 - GLASS IN BUILDING - PAINTED GLASS FOR INTERNAL USE - PART 2: EVALUATION OF CONFORMITY |
BS EN 15254-6:2014 | Extended application of results from fire resistance tests. Non-loadbearing walls Curtain walling |
12/30252241 DC : DRAFT JAN 2012 | BS EN 15254-6 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 6: CURTAIN WALLING |
PD CEN/TR 14819-1:2004 | Safety recommendations for cableway installations designed to carry persons. Prevention and fight against fire Funicular railways in tunnels |
04/30099887 DC : DRAFT MAY 2004 | PREN 14963 - ROOF COVERINGS - CONTINUOUS ROOFLIGHTS OF PLASTICS WITH UPSTANDS - CLASSIFICATION, REQUIREMENTS AND TEST METHODS |
DIN EN 1999-1-2:2010-12 | Eurocode 9: Design of aluminium structures - Part 1-2: Structural fire design (includes Corrigendum AC:2009) |
16/30299842 DC : 0 | BS EN 50518 - MONITORING AND ALARM RECEIVING CENTRE |
11/30253102 DC : 0 | BS EN 16351 - TIMBER STRUCTURES - CROSS LAMINATED TIMBER - REQUIREMENTS |
16/30332917 DC : 0 | BS EN 13915 - PREFABRICATED GYPSUM PLASTERBOARD PANELS WITH A CELLULAR PAPERBOARD CORE - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
17/30313628 DC : 0 | BS EN ISO 20023 - SOLID BIOFUELS - SAFETY OF SOLID BIOFUEL PELLETS - SAFE HANDLING AND STORAGE OF WOOD PELLETS IN RESIDENTIAL AND OTHER SMALL-SCALE APPLICATIONS |
BS EN 15269-10:2011 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies including their elements of building hardware Fire resistance of steel rolling shutter assemblies |
DD CEN/TS 45545-3:2009 | Railway applications. Fire protection on railway vehicles Fire resistance requirements for fire barriers |
08/30093077 DC : DRAFT MAR 2008 | BS EN 15269-10 - EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 10: FIRE RESISTANCE OF STEEL ROLLING SHUTTER ASSEMBLIES |
07/30171469 DC : DRAFT DEC 2007 | BS EN 15080-15 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - PART 15: LINEAR JOINT SEALS |
UNE-EN 15269-7:2011 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 7: Fire resistance for steel sliding doorsets |
UNI EN 13369 : 2013 | COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
16/30343249 DC : 0 | BS EN 179 - BUILDING HARDWARE - EMERGENCY EXIT DEVICES OPERATED BY A LEVER HANDLE OR PUSH PAD, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
PREN 13964 : DRAFT 2013 | SUSPENDED CEILINGS - REQUIREMENTS AND TEST METHODS |
EN 15254-4:2008+A1:2011 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 4: Glazed constructions |
PREN 17064 : DRAFT 2016 | SAFETY REQUIREMENTS FOR CABLEWAY INSTALLATIONS DESIGNED TO CARRY PERSONS - PREVENTION AND FIGHT AGAINST FIRE |
NF EN 1090-1 : 2009 + A1 2012 | EXECUTION OF STEEL STRUCTURES AND ALUMINIUM STRUCTURES - PART 1: REQUIREMENTS FOR CONFORMITY ASSESSMENT OF STRUCTURAL COMPONENTS |
I.S. EN 16153:2013 | LIGHT TRANSMITTING FLAT MULTIWALL POLYCARBONATE (PC) SHEETS FOR INTERNAL AND EXTERNAL USE IN ROOFS, WALLS AND CEILINGS - REQUIREMENTS AND TEST METHODS |
I.S. EN 15269-10:2011 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 10: FIRE RESISTANCE OF STEEL ROLLING SHUTTER ASSEMBLIES |
UNE-EN 15254-2:2010 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 2: Masonry and Gypsum Blocks |
I.S. EN 13369:2018 | COMMON RULES FOR PRECAST CONCRETE PRODUCTS |
BS EN 1279-5 : 2005 | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY |
UNE-EN 15080-8:2011 | Extended application of results from fire resistance tests - Part 8: Beams |
UNE-EN 12602:2011 | Prefabricated reinforced components of autoclaved aerated concrete |
I.S. EN 15254-2:2009 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NONLOADBEARING WALLS - PART 2: MASONRY AND GYPSUM BLOCKS |
I.S. EN 50583-1:2016 | PHOTOVOLTAICS IN BUILDINGS - PART 1: BIPV MODULES |
UNE-EN 13815:2012 | Fibrous gypsum plaster casts - Definitions, requirements and test methods |
UNI EN 15269-1 : 2010 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 1: GENERAL REQUIREMENTS |
ISO/TR 12470-2:2017 | Fire-resistance tests Guidance on the application and extension of results from tests conducted on fire containment assemblies and products Part 2: Non-loadbearing elements |
UNI EN 15269-2 : 2012 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 2: FIRE RESISTANCE OF HINGED AND PIVOTED STEEL DOORSETS |
17/30359220 DC : 0 | BS EN 15269-20 - EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 20: SMOKE CONTROL FOR DOORS, SHUTTERS AND OPENABLE WINDOWS |
XP CEN/TS 1992-4-1 : 2009 XP | DESIGN FOR FASTENINGS FOR USE IN CONCRETE - PART 4-1: GENERAL |
17/30359850 DC : 0 | BS EN 14178-2 - GLASS IN BUILDING - BASIC ALKALINE EARTH SILICATE GLASS PRODUCTS - PART 2: PRODUCT STANDARD |
UNI EN 15254-4 : 2011 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
PREN 1504-3 : DRAFT 2015 | PRODUCTS AND SYSTEMS FOR THE PROTECTION AND REPAIR OF CONCRETE STRUCTURES - DEFINITIONS, REQUIREMENTS, QUALITY CONTROL AND AVCP - PART 3: REPAIR CONCRETE AND MORTARS |
EN 15254-5:2018 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 5: Metal sandwich panel construction |
UNE-EN 15254-4:2009 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 4: Glazed constructions |
BS EN 15254-4 : 2008 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
I.S. EN 15254-4:2008 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTIONS |
I.S. EN 15283-2:2008 | GYPSUM BOARDS WITH FIBROUS REINFORCEMENT - DEFINITIONS, REQUIREMENTS AND TEST METHODS - PART 2: GYPSUM FIBRE BOARDS |
I.S. EN 15254-5:2009 | EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 5: METAL SANDWICH PANEL CONSTRUCTION |
I.S. EN 12602:2016 | PREFABRICATED REINFORCED COMPONENTS OF AUTOCLAVED AERATED CONCRETE |
EN 45545-1 : 2013 COR 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 1: GENERAL |
DIN EN 13658-2:2005-09 | Metal lath and beads - Definitions, requirements and test methods - Part 2: External rendering |
DIN EN 13658-1:2005-09 | Metal lath and beads - Definitions, requirements and test methods - Part 1: Internal plastering |
DIN EN 179:2008-04 | Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods |
DIN EN 520:2009-12 | Gypsum plasterboards - Definitions, requirements and test methods (includes Amendment A1:2009) |
BS EN 1366-7:2004 | Fire resistance tests for service installations Conveyor systems and their closures |
BS EN 1993-1-2:2005 | Eurocode 3. Design of steel structures General rules - Structural fire design |
UNE-EN 13964:2016 | Suspended ceilings - Requirements and test methods |
DD ISO/TS 20100:2008 | Gaseous hydrogen. Fuelling stations |
BS EN 1036-2:2008 | Glass in building. Mirrors from silver-coated float glass for internal use Evaluation of conformity; product standard |
BS EN 12150-2:2004 | Glass in building. Thermally toughened soda lime silicate safety glass Evaluation of conformity/Product standard |
BS EN 14496:2005 | Gypsum based adhesives for thermal/acoustic insulation composite panelsa nd plasterboards. Definitions, requirements and test methods |
BS EN 15319:2007 | General principles of design of fibrous (gypsum) plaster works |
UNE-EN 303-5:2013 | Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking |
BS EN 13964:2014 | Suspended ceilings. Requirements and test methods |
BS EN 14081-1:2016 | Timber structures. Strength graded structural timber with rectangular cross section General requirements |
BS EN 13024-2:2004 | Glass in building. Thermally toughened borosilicate safety glass Evaluation of conformity/Product standard |
BS EN 14179-2:2005 | Glass in building. Heat-soaked thermally-toughened soda lime silicate safety glass Evaluation of conformity/product standard |
CEN/TR 15123:2005 | Design, preparation and application of internal polymer plastering systems |
EN 13063-3:2007 | Chimneys - System chimneys with clay/ceramic flue liners - Part 3: Requirements and test methods for air flue system chimneys |
EN 13063-2:2005+A1:2007 | Chimneys - System chimneys with clay/ceramic flue liners - Part 2: Requirements and test methods under wet conditions |
EN 1036-2:2008 | Glass in building - Mirrors from silver-coated float glass for internal use - Part 2: Evaluation of conformity; product standard |
EN 50583-1:2016 | Photovoltaics in buildings - Part 1: BIPV modules |
EN 1366-3:2009 | Fire resistance tests for service installations - Part 3: Penetration seals |
DIN EN 14321-2:2005-10 | Glass in building - Thermally toughened alkaline earth silicate safety glass - Part 2: Evaluation of conformity/Product standard |
DIN EN 14600:2006-03 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
DIN EN 357:2005-02 | GLASS IN BUILDING - FIRE-RESISTANT GLAZED ELEMENTS WITH TRANSPARENT OR TRANSLUCENT GLASS PRODUCTS - CLASSIFICATION OF FIRE RESISTANCE |
DIN EN 13063-1:2007-10 | CHIMNEYS - SYSTEM CHIMNEYS WITH CLAY/CERAMIC FLUE LINERS - PART 1: REQUIREMENTS AND TEST METHODS FOR SOOTFIRE RESISTANCE |
DIN EN 14915:2013-12 | SOLID WOOD PANELLING AND CLADDING - CHARACTERISTICS, REQUIREMENTS AND MARKING |
EN 15287-1:2007+A1:2010 | Chimneys - Design, installation and commissioning of chimneys - Part 1: Chimneys for non-roomsealed heating appliances |
EN 12209:2016 | Building hardware - Mechanically operated locks and locking plates - Requirements and test methods |
CEN/TR 15124:2005 | Design, preparation and application of internal gypsum plastering systems |
EN 13279-1:2008 | Gypsum binders and gypsum plasters - Part 1: Definitions and requirements |
DIN EN 13063-2:2007-10 | CHIMNEYS - SYSTEM CHIMNEYS WITH CLAY/CERAMIC FLUE LINERS - PART 2: REQUIREMENTS AND TEST METHODS UNDER WET CONDITIONS |
DIN EN 1090-1:2012-02 | Execution of steel structures and aluminium structures - Part 1: Requirements for conformity assessment of structural components (includes Amendment A1:2011) |
CEN/TS 45545-3:2009 | Railway applications - Fire protection on railway vehicles - Part 3: Fire resistance requirements for fire barriers |
DIN EN 14989-1:2007-05 | Chimneys - Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications - Part 1: Vertical air/flue terminals for C6-type appliances |
CEI EN IEC 61936-1:2024 | Power installations exceeding 1 kV AC and 1,5 kV DC Part 1: AC |
UNE-EN 14915:2013 | Solid wood panelling and cladding - Characteristics, evaluation of conformity and marking |
UNE-EN 1279-5:2006 | Glass in building - Insulating glass units - Part 5: Evaluation of conformity |
UNE-EN 16153:2013 | Light transmitting flat multiwall polycarbonate (PC) sheets for internal and external use in roofs, walls and ceilings - Requirements and test methods |
EN 13381-9:2015 | Test methods for determining the contribution to the fire resistance of structural members - Part 9: Applied fire protection systems to steel beams with web openings |
EN 15080-12:2011 | Extended application of results from fire resistance tests - Part 12: Loadbearing masonry walls |
EN 15254-6:2014 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 6: Curtain walling |
EN 1364-3:2014 | Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration (complete assembly) |
EN 1366-5:2010 | Fire resistance tests for service installations - Part 5: Service ducts and shafts |
EN 1365-3:1999 | Fire resistance tests for loadbearing elements - Part 3: Beams |
EN 1364-1:1999 | Fire resistance tests for non-loadbearing elements - Part 1: Walls |
PREN 15269-6 : DRAFT 2015 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 6: FIRE RESISTANCE OF SLIDING TIMBER DOORSETS |
EN 13216-1:2004 | Chimneys - Test methods for system chimneys - Part 1: General test methods |
EN 15269-3:2012 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 3: Fire resistance of hinged and pivoted timber doorsets and openable timber framed windows |
EN 13381-4:2013 | Test methods for determining the contribution to the fire resistance of structural members - Part 4: Applied passive protection to steel members |
ISO 13943:2017 | Fire safety — Vocabulary |
EN 1366-4:2006+A1:2010 | Fire resistance tests for service installations - Part 4: Linear joint seals |
EN 15269-20:2009 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 20: Smoke control for hinged and pivoted steel, timber and metal framed glazed doorsets |
EN 15080-8:2009 | Extended application of results from fire resistance tests - Part 8: Beams |
EN 1366-7:2004 | Fire resistance tests for service installations - Part 7: Conveyor systems and their closures |
EN 13381-2:2014 | Test methods for determining the contribution to the fire resistance of structural members - Part 2: Vertical protective membranes |
EN 1366-6:2004 | Fire resistance tests for service installations - Part 6: Raised access and hollow core floors |
EN 15269-5:2014+A1:2016 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 5: Fire resistance of hinged and pivoted metal framed glazed doorsets and openable windows |
EN 1366-3:2009 | Fire resistance tests for service installations - Part 3: Penetration seals |
EN 13381-8:2013 | Test methods for determining the contribution to the fire resistance of structural members - Part 8: Applied reactive protection to steel members |
EN 1364-4:2014 | Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration |
EN 13381-6:2012 | Test methods for determining the contribution to the fire resistance of structural members - Part 6: Applied protection to concrete filled hollow steel columns |
EN 13381-5:2014 | Test methods for determining the contribution to the fire resistance of structural members - Part 5: Applied protection to concrete/profiled sheet steel composite member |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
EN 1363-1:2012 | Fire resistance tests - Part 1: General Requirements |
EN 15269-2:2012 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 2: Fire resistance of hinged and pivoted steel doorsets |
EN 13381-3:2015 | Test methods for determining the contribution to the fire resistance of structural members - Part 3: Applied protection to concrete members |
PREN 15269-11 : DRAFT 2013 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 11: FIRE RESISTANCE OF OPERABLE FABRIC CURTAINS |
EN 13381-1:2014 | Test methods for determining the contribution to the fire resistance of structural members - Part 1: Horizontal protective membranes |
EN 15269-7:2009 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 7: Fire resistance for steel sliding doorsets |
EN 15269-1:2010 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 1: General requirements |
EN 15882-3:2009 | Extended applications of results from fire resistance tests for service installations - Part 3: Penetration seals |
EN 1365-4:1999 | Fire resistance tests for loadbearing elements - Part 4: Columns |
EN 1363-2:1999 | Fire resistance tests - Part 2: Alternative and additional procedures |
EN 15269-10:2011 | Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies including their elements of building hardware - Part 10: Fire resistance of steel rolling shutter assemblies |
EN 1365-5:2004 | Fire resistance tests for loadbearing elements - Part 5: Balconies and walkways |
EN 14135:2004 | Coverings - Determination of fire protection ability |
EN 15254-2:2009 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 2: Masonry and Gypsum Blocks |
ENV 13381-7:2002 | Test methods for determining the contribution to the fire resistance of structural members - Part 7: Applied protection to timber members |
EN 15254-4:2008+A1:2011 | Extended application of results from fire resistance tests - Non-loadbearing walls - Part 4: Glazed constructions |
EN 15882-4:2012 | Extended application of results from fire resistance tests for service installations - Part 4: Linear joint seals |
EN 1365-2:2014 | Fire resistance tests for loadbearing elements - Part 2: Floors and roofs |
EN 14600:2005 | Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification |
EN 1365-6:2004 | Fire resistance tests for loadbearing elements - Part 6: Stairs |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.