BS EN 15193:2007
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Energy performance of buildings. Energy requirements for lighting
Hardcopy , PDF
30-06-2017
English
30-04-2011
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Calculating energy used for lighting
4.1 Total energy used for lighting
4.1.1 Total estimated energy
4.1.2 Total annual energy used for lighting
4.2 Lighting Energy Numeric Indicator (LENI)
5 Metering
5.1 General
5.2 Load segregation
5.3 Remote metering
6 Calculation of lighting energy in buildings
6.1 Installed lighting power
6.1.1 General
6.1.2 Luminaire
6.1.3 Luminaire power (P[i])
6.1.4 Parasitic powers (P[ci] and P[ei])
6.2 Calculation methods
6.2.1 Quick method
6.2.2 Comprehensive method
6.2.3 Determination of constant illuminance
factor F[c]
7 Benchmark of lighting energy requirements
8 Lighting design and practice
Annex A (informative) - Metering of lighting circuit
Annex B (informative) - Measurement method of total
power of luminaires and associated
parasitic power
B.1 Introduction
B.2 Test measurement of luminaire power during
normal operation
B.3 Standard test conditions
B.4 Electrical measuring instruments
B.5 Test luminaires
B.6 Test voltage
B.7 Luminaire power (P[i])
B.8 Luminaire parasitic power with lamps
off (P[pi])
B.9 Emergency lighting luminaire parasitic
input power (P[ei])
B.10 Lighting controls standby parasitic
power (P[ci])
B.11 Default luminaire power for existing
lighting installations
B.12 Default parasitic energy for existing
lighting installations
Annex C (informative) - Determination of the daylight
dependency factor F[D,n]
C.1 General
C.2 Building segmentation: Spaces benefiting
from daylight
C.3 Daylight supply
C.3.1 Vertical facades
C.3.2 Rooflights
C.4 Daylight dependent artificial lighting
control, F[D,C]
C.5 Monthly method
Annex D (informative) - Determination of occupancy
dependency factor F[O]
D.1 Introduction
D.2 Detailed determination of F[O]
D.3 Motivation for the choice of FO functions
Annex E (informative) - Determination of the constant
illuminance factor F[C]
E.1 Introduction
E.2 Power for constant illuminance factor
E.3 Constant illuminance factor (F[c])
Annex F (informative) - Benchmark values and lighting
design criteria
Annex G (informative) - Default values
G.1 The default values for annual operating
hours relating to building type are given
in Table G.1
Annex H (informative) - Other considerations
H.1 Individual dimming
H.2 Algorithmic lighting
H.3 Light pipes
H.4 Lighting installations with scene setting
H.5 Daylight guidance
H.5.1 Vertical facades
H.5.2 Rooflights
Annex I (informative) - List of Symbols
Bibliography
Describes the calculation methodology for the evaluation of the amount of energy used for indoor lighting inside the building and provides a numeric indicator for lighting energy requirements used for certification purposes.
Committee |
EL/1
|
DevelopmentNote |
Supersedes 06/30124376 DC. (11/2007)
|
DocumentType |
Standard
|
Pages |
82
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This European Standard specifies the calculation methodology for the evaluation of the amount of energy used for indoor lighting inside the building and provides a numeric indicator for lighting energy requirements used for certification purposes. This European Standard can be used for existing buildings and for the design of new or renovated buildings. It also provides reference schemes to base the targets for energy allocated for lighting usage. This European Standard also provides a methodology for the calculation of instantaneous lighting energy use for the estimation of the total energy performance of the building. Parasitic powers not included in the luminaire are excluded.
In this European Standard, the buildings are classified in the following categories: offices, education buildings, hospitals, hotels, restaurants, sports facilities, wholesale and retail services and manufacturing factories.
In some locations outside lighting may be fed with power from the building. This lighting may be used for illumination of the façade, open-air car park lighting, security lighting, garden lighting etc. These lighting systems may consume significant energy and if they are fed from the building, this load will not be included in the Lighting Energy Numeric Indicator or into the values used for heating and cooling load estimate. If metering of the lighting load is employed, these loads may be included in the measured lighting energy.
Standards | Relationship |
NS EN 15193 : 2007 AC 2010 | Identical |
SN EN 15193 : 2007 CORR 2011 | Identical |
NF EN 15193 : 2007 | Identical |
NBN EN 15193 : 2008 COR 2010 | Identical |
I.S. EN 15193:2007 | Identical |
NEN EN 15193 : 2007 C1 2010 | Identical |
UNI EN 15193 : 2008 | Identical |
EN 15193:2007 | Equivalent |
EN 15193:2007/AC:2010 | Identical |
DIN EN 15193:2008-01 | Identical |
BS 8206-2:2008 | Lighting for buildings Code of practice for daylighting |
EN 12464-1:2011 | Light and lighting - Lighting of work places - Part 1: Indoor work places |
IEC 60570:2003+AMD1:2017 CSV | Electrical supply track systems for luminaires |
EN 12193:2007 | Light and lighting - Sports lighting |
EN 13032-1:2004+A1:2012 | Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 1: Measurement and file format |
EN 1838:2013 | Lighting applications - Emergency lighting |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.