BS EN 15417:2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Gas-fired central heating boilers. Specific requirements for condensing boilers with a nominal heat input greater than 70 kW but not exceeding 1000 kW
Hardcopy , PDF
30-11-2012
BS EN 15502-1:2012+A1:2015
BS EN 15502-1 : 2012
BS EN 15502-2-1 : 2012
BS EN 15502-2-2:2014
BS EN 15502-2-1:2012+A1:2016
English
31-07-2006
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Classification of boilers
4.1 Gases and categories
4.2 Classification according to the mode of
evacuation of the combustion products
4.3 Classification according to operating conditions
4.3.1 Gas condensing boiler
4.3.2 Standard boiler
5 Constructional requirements
5.1 Materials in contact with condensate
5.2 Removal of condensate
5.3 Chemical composition of the condensate
5.4 Control of the combustion products temperature
6 Operational requirements
6.1 General
6.2 Verification of the nominal condensing output
6.3 Formation of condensate
6.4 Temperature of combustion products
6.5 Combustion
6.6 Useful efficiency
6.6.1 General
6.6.2 Useful at the nominal heat input
6.6.3 Useful efficiency at part load
7 Test methods
7.1 General
7.2 Verification of the nominal condensing output
7.3 Formation of condensate
7.4 Temperature of combustion products
7.5 Combustion
7.5.1 Normal conditions
7.5.2 Condensate discharge blockage
7.6 Useful efficiency
7.6.1 General
7.6.2 Useful efficiency at nominal heat input
7.6.3 Useful efficiency at part load
8 Marking
8.1 Data plate
8.2 Instructions
8.2.1 Technical instructions for the installer
8.2.2 Use and maintenance instructions for the
user
Annex A (normative) Correction for the determined
efficiency in the low water temperature
test of condensing boilers
Annex ZA (informative) Clauses of this European standard
addressing essential requirements or other
provisions of EU Directives
Bibliography
Determines gas-fired central heating boilers, which are declared by the manufacturer to be 'condensing boilers': - of types C (excluding appliances without a fan) and B; - using one or more gases corresponding to the three gas families; - for which the nominal heat input is greater than 70 kW but not exceeding 1000 kW.
Committee |
GSE/29
|
DevelopmentNote |
Supersedes 05/30142225 DC (08/2006) Superseded by BS EN 15502-2-1, BS EN 15502-1 & BS EN 15502-2-2 but remains current and will be withdrawn on 31/07/2017. (09/2014)
|
DocumentType |
Standard
|
Pages |
20
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NEN EN 15417 : 2006 | Identical |
NBN EN 15417 : 2007 | Identical |
NS EN 15417 : 1ED 2006 | Identical |
EN 15417:2006 | Identical |
NF EN 15417 : 2006 | Identical |
I.S. EN 15417:2006 | Identical |
UNI EN 15417 : 2006 | Identical |
UNE-EN 15417:2007 | Identical |
SN EN 15417 : 2006 | Identical |
DIN EN 15417:2006-11 | Identical |
EN 13836:2006 | Gas fired central heating boilers - Type B boilers of nominal heat input exceeding 300 kW, but not exceeding 1 000 kW |
EN 437:2003+A1:2009 | Test gases - Test pressures - Appliance categories |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.