Control for heating, ventilating and air-conditioning applications. Electronic individual zone control equipment
Hardcopy , PDF
21-06-2017
English
31-05-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviations
5 Functionality
6 Test method
7 Classification and designation
8 Marking and documentation
Annex A (normative) - Functional and acceptance test
Annex B (informative) - Data
Bibliography
Describes the applications, functionality set and application performance for electronic individual zone control equipment. The applications are for cooling and hot water or electrical heating as described in Annex B.
Committee |
RHE/16
|
DevelopmentNote |
Supersedes 06/30148036 DC. (09/2008)
|
DocumentType |
Standard
|
Pages |
70
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
EN 15500:2008 | Identical |
IEC 60038:2009 | IEC standard voltages |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
EN 12098-5:2017 | Energy Performance of Buildings - Controls for heating systems - Part 5: Start-stop schedulers for heating systems - Modules M3-5,6,7,8 |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
ISO 16484-2:2004 | Building automation and control systems (BACS) — Part 2: Hardware |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
ISO 16484-3:2005 | Building automation and control systems (BACS) — Part 3: Functions |
EN ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
EN ISO 16484-3:2005 | Building automation and control systems (BACS) - Part 3: Functions (ISO 16484-3:2005) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 12098-2:2001 | Controls for heating systems - Part 2: Optimum start-stop control equipment for hot water heating systems |
EN ISO 16484-2:2004 | Building automation and control systems (BACS) - Part 2: Hardware (ISO 16484-2:2004) |
EN 12098-1:2017 | Energy Performance of Buildings - Controls for heating systems - Part 1: Control equipment for hot water heating systems - Modules M3-5, 6, 7, 8 |