BS EN 15882-2:2015

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Extended application of results from fire resistance tests for service installations Fire dampers

Available format(s)

Hardcopy , PDF

Superseded date

10-10-2022

Superseded by

BS EN 15882-2:2022

Language(s)

English

Published date

30-04-2015

€217.36
Excluding VAT

Committee
FSH/22/-/4
DocumentType
Standard
Pages
26
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

This European Standard provides guidance and rules to notified bodies (for fire dampers) to allow them to produce/validate an extended field of application report for fire dampers. This standard identifies the parameters that affect the fire resistance of dampers. It also identifies the factors that need to be considered when deciding whether, or by how much, the parameter can be extended when contemplating the fire resistance performance of an untested, or untestable variation in the construction. This European Standard explains the principles behind how a conclusion on the influence of specific parameters/constructional details relating to the relevant criteria (E,I,S) can be achieved. This European Standard does not cover dampers used for smoke control. This European Standard only applies to extended fields of application based on tests successfully undertaken to EN1366‑2 . Only test reports that have a total test time where the criteria are fulfilled that is in excess of the required classification period by a margin of either 10%or 12min, whichever is the least, are to be considered. Each classification (E,I,S) is to be considered individually – consequently E (134min achieved) may be extended, but EI (61min achieved) may not be extended for a classification of EI60. Additionally, leakage determined during such tests is to be at least 10%below the leakage limits for E, or for E-S, dependent on classification achieved, given in EN13501‑3 before the EXAP rules can be applied. The 10%below the leakage limits is to be fulfilled for the extended period in addition to the classification period. By application of this European Standard, it should be possible to identify what specifications should be tested to maximize the field of application. Some information on test programmes is given for guidance purposes.

Standards Relationship
EN 15882-2:2015 Identical

EN 15882-1:2011+A1:2017 Extended application of results from fire resistance tests for service installations - Part 1: Ducts
EN 1366-1:2014 Fire resistance tests for service installations - Part 1: Ventilation ducts
EN 13501-3:2005+A1:2009 Fire classification of construction products and building elements - Part 3: Classification using data from fire resistance tests on products and elements used in building service installations: fire resisting ducts and fire dampers
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 1366-2:2015 Fire resistance tests for service installations - Part 2: Fire dampers
ISO 10294-4:2001 Fire resistance tests Fire dampers for air distribution systems Part 4: Test of thermal release mechanism
ISO 10294-1:1996 Fire resistance tests Fire dampers for air distribution systems Part 1: Test method