• Shopping Cart
    There are no items in your cart

BS EN 50125-2:2002

Current

Current

The latest, up-to-date edition.

Railway applications. Environmental conditions for equipment Fixed electrical installations

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-08-2010

€156.59
Excluding VAT

1 Scope
2 Normative references
3 Definitions
4 Environmental conditions
Annex A (informative) - Conditions relating to tunnels
Annex ZZ (informative) - Coverage of Essential
         Requirements of EC Directives
Bibliography

Deals with the environmental influences on fixed electrical installations for traction power supply and equipment essential to operate a railway: - in open air; - in covered areas; - in tunnels; - within enclosures placed in above areas.

Committee
GEL/9/3
DevelopmentNote
Supersedes 98/262546 DC. (04/2003)
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Current
Supersedes

This European Standard takes into account environmental conditions within Europe.

This European Standard deals with the environmental influences on fixed electrical installations for traction power supply and equipment essential to operate a railway

  • in open air;

  • in covered areas;

  • in tunnels;

  • within enclosures placed in above areas.

Escalators, lifts, fire protection, lighting in tunnels and on platforms, ticket machines, ventilation systems and non-essential functions are not included.

Such influences include altitude, temperature and humidity, air movement, rain, snow, hail, ice, sand, solar radiation, lightning, pollution, vibration, shocks and EMC.

This standard does not specify the test requirements for equipment.

In case of environmental conditions not covered by the standard the data to be adopted for a specific project should be clearly stipulated when preparing a specification.

This standard is not intended to apply to cranes, installations in underground mines, suspended cable cars and funicular railways.

Nuclear radiation is excluded.

Signalling and telecommunications systems are not considered in this standard.

Fixed installed signalling and telecommunication equipment shall comply with EN 50125-3 .

EN 50125-3 : 2003 COR 2010 RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 3: EQUIPMENT FOR SIGNALLING AND TELECOMMUNICATIONS
EN 50124-2:2017 Railway applications - Insulation coordination - Part 2: Overvoltages and related protection
HD 478.2.3 : 200S1 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - AIR PRESSURE
HD 478.2.2 : 200S1 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - PRECIPITATION AND WIND
EN 50123-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 1: General
HD 478.2.1 : 200S1 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - TEMPERATURE AND HUMIDITY
IEC 60721-2-1:2013 Classification of environmental conditions - Part 2-1: Environmental conditions appearing in nature - Temperature and humidity
EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
IEC 60721-2-2:2012 Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind
EN 50125-1:2014 Railway applications - Environmental conditions for equipment - Part 1: Rolling stock and on-board equipment
EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60721-3-2:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation
ENV 1991-2-4 : 1995 EUROCODE 1: BASIS OF DESIGN AND ACTIONS ON STRUCTURES - ACTIONS ON STRUCTURES - WIND ACTIONS (TOGETHER WITH UNITED KINGDOM NATIONAL APPLICATION DOCUMENT)
EN 50121-5:2017 Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
EN 50123-4:2003/A1:2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 4: OUTDOOR D.C. DISCONNECTORS, SWITCH-DISCONNECTORS AND EARTHING SWITCHES
EN 60721-3-2:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 60721-3-4:1995/A1:1997 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 4: STATIONARY USE AT NON-WEATHER-PROTECTED LOCATIONS
IEC 60721-2-3:2013 Classification of environmental conditions - Part 2-3: Environmental conditions appearing in nature - Air pressure
EN 60721-3-3 : 95 AMD 2 97 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.