EN 50124-1:2017
Current
The latest, up-to-date edition.
Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
03-03-2017
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Basis for insulation coordination
5 Requirements and dimensioning rules for clearances
6 Dimensioning rules for creepage distances
7 Tests and measurements
8 Specific requirements for applications in the
railway field
Annex A (normative) - Tables
Annex B (normative) - Provisions for type and routine
dielectric tests for equipment
Annex C (normative) - Methods of measuring creepage
distances and clearances
Annex D (normative) - Correlation between U[n] and U[Nm]
Annex E (informative) - Macro-environmental conditions
Annex F (informative) - Application guide
Annex ZZ (informative) Relationship between this
European Standard and the Essential
Requirements of EU Directive 2008/57/EC
Bibliography
This European Standard deals with insulation coordination in railways. It applies to equipment for use in signalling, rolling stock and fixed installations.Insulation coordination is concerned with the selection, dimensioning and correlation of insulation both within and between items of equipment. In dimensioning insulation, electrical stresses and environmental conditions are taken into account. For the same conditions and stresses, these dimensions are the same.An objective of insulation coordination is to avoid unnecessary over dimensioning of insulation.This standard specifies:-requirements for clearances and creepage distances for equipment;-general requirements for tests pertaining to insulation coordination.The term equipment relates to a section as defined in 3.3 it may apply to a system, a sub-system, an apparatus, a part of an apparatus, or a physical realization of an equipotential line.This standard does not deal with:-distances through solid or liquid insulation;-distances through gases other than air;-distances through air not at atmospheric pressure;-equipment used under extreme conditions.Product standards should align with this generic standard.However, they may require, with justification, different requirements due to safety and/or reliability reasons, e.g. for signalling, and/or particular operating conditions of the equipment itself, e.g. overhead contact lines which should comply with EN 50119.This standard also gives provisions for dielectric tests (type tests or routine tests) on equipment (see Annex B).NOTEFor safety critical systems, specific requirements are needed. These requirements are given in the product specific signalling standard EN 50129.
| Committee |
CLC/TC 9X
|
| DevelopmentNote |
Supersedes PREN 50124-1. (03/2017)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| OVE EN 50124-1:2018 01 01 | Identical |
| DIN EN 50124-1 Berichtigung 1:2023-06 | Identical |
| VDE 0115-107-1 Berichtigung 1:2023-06 | Identical |
| BS EN 50124-1:2017 | Identical |
| NEN EN 50124-1 : 2017 | Identical |
| VDE 0115-107 : DRAFT AMD 2 2004 | Identical |
| CEI EN 50124-1:2018 | Identical |
| NBN EN 50124-1 : 2001 AMD 2 2006 | Identical |
| I.S. EN 50124-1:2017 | Identical |
| PN EN 50124-1 : 2017 | Identical |
| NF EN 50124-1 : 2017 | Identical |
| CEI EN 50124-1:2017 | Identical |
| DIN EN 50124-1:2017-12 | Identical |
| OVE/ONORM EN 50124-1 : 2011-05 | Identical |
| UNE-EN 50124-1:2017 | Identical |
| VDE 0115-107-1:2017-12 | Identical |