BS EN 50152-3-2:2016
Current
The latest, up-to-date edition.
Railway applications. Fixed installations. Particular requirements for a.c. switchgear Measurement, control and protection devices for specific use in a.c. traction systems. Current transformers
Hardcopy , PDF
English
30-06-2016
European foreword
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Service conditions
5 Rating
6 Design and construction
7 Tests
8 Rules for transport, storage, erection, operation
and maintenance
9 Safety
10 Influence of the product on the environment
11 Information to be given with enquiries, tenders
and orders
Bibliography
Pertains to new current transformers which are: - intended for use in indoor or outdoor fixed installations in tractions systems and; - operated with an a.c. line voltage and frequency as specified in EN 50163.
Committee |
GEL/9/3
|
DevelopmentNote |
Supersedes 96/214118 DC. (09/2005) Supersedes 15/30314792 DC. (06/2016)
|
DocumentType |
Standard
|
Pages |
16
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This EN50152‑3‑2 is applicable to new current transformers which are: intended for use in indoor or outdoor fixed installations in tractions systems, and operated with an a.c. line voltage and frequency as specified in EN50163 . NOTE1 EN50163 specifies the a.c. traction systems 15kV 16,7Hz and 25kV 50Hz. NOTE2 As rails of a.c. traction systems are typically connected to earth and included in the return current path, all phase to earth voltages are subject to the limits as given in EN50163 . Nevertheless conductor to conductor voltages are some times higher e.g. in autotransformer systems. Current transformers are mainly used with: measuring instruments, protective devices. This EN50152‑3‑2 also applies to current transformers other than inductive types as far as reasonably possible. Requirements of this EN50152‑3‑2 have priority. NOTE3 Combined current and voltage transformers are typically not used in fixed installations in traction systems.
Standards | Relationship |
NF EN 50152-3-2 : 2017 | Identical |
DIN EN 50152-3-2 : 2016 | Identical |
NEN EN 50152-3-2 : 2016 | Identical |
I.S. EN 50152-3-2:2016 | Identical |
EN 50152-3-2:2016 | Identical |
SN EN 50152-3-2 : 2016 | Identical |
UNE-EN 50152-3-2:2016 | Identical |
EN 61291-1:2012 | Optical amplifiers - Part 1: Generic specification |
EN 60825-1:2014/AC:2017-06 | SAFETY OF LASER PRODUCTS - PART 1: EQUIPMENT CLASSIFICATION AND REQUIREMENTS (IEC 60825-1:2014) |
EN 61291-5-2:2017 | Optical amplifiers - Part 5-2: Qualification specifications - Reliability qualification for optical fibre amplifiers |
IEC 62148-11:2009 | Fibre optic active components and devices - Package and interface standards - Part 11: 14-pin active device modules |
EN 62149-3:2014 | Fibre optic active components and devices - Performance standards - Part 3: Modulator-integrated laser diode transmitters for 2,5-Gbit/s to 40-Gbit/s fibre optic transmission systems |
EN 62572-3:2016 | Fibre optic active components and devices - Reliability standards - Part 3: Laser modules used for telecommunication |
IEC 60825-1:2014 | Safety of laser products - Part 1: Equipment classification and requirements |
IEC 61290-6-1:1998 | Optical fibre amplifiers - Basic specification - Part 6-1: Test methods for pump leakage parameters - Optical demultiplexer |
EN 62148-11:2009 | Fibre optic active components and devices - Package and interface standards - Part 11: 14-pin active device modules |
IEC 61291-4:2011 | Optical amplifiers - Part 4: Multichannel applications - Performance specification template |
IEC 62149-3:2014 | Fibre optic active components and devices - Performance standards - Part 3: Modulator-integrated laser diode transmitters for 2,5-Gbit/s to 40-Gbit/s fibre optic transmission systems |
IEC TR 61931:1998 | Fibre optic - Terminology |
EN 61291-4:2012 | Optical amplifiers - Part 4: Multichannel applications - Performance specification template |
IEC 61291-5-2:2017 | Optical amplifiers - Part 5-2: Qualification specifications - Reliability qualification for optical fibre amplifiers |
IEC 61291-1:2012 | Optical amplifiers - Part 1: Generic specification |
IEC 62572-3:2016 | Fibre optic active components and devices - Reliability standards - Part 3: Laser modules used for telecommunication |
IEC TR 62572-2:2008 | Fibre optic active components and devices - Reliability standards - Part 2: Laser module degradation |
EN 62149-1:2012 | Fibre optic active components and devices - Performance standards - Part 1: General and guidance |
IEC 62149-1:2011 | Fibre optic active components and devices - Performance standards - Part 1: General and guidance |
EN 61290-4-3:2015 | Optical amplifiers - Test methods - Part 4-3: Power transient parameters - Single channel optical amplifiers in output power control |
IEC TS 62538:2008 | Categorization of optical devices |
EN 61290-6-1:1998 | Optical fibre amplifiers - Basic specification - Part 6-1: Test methods for pump leakage parameters - Optical demultiplexer |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.