BS EN 50200:2015
Current
The latest, up-to-date edition.
Method of test for resistance to fire of unprotected small cables for use in emergency circuits
Hardcopy , PDF
English
31-12-2015
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Test environment
5 Test apparatus
6 Verification procedure for source of heat
7 Test sample (Electric power and control
cables with rated voltage up to and including
600 V/1000 V)
8 Cable test procedure (Electric power and
control cables with rated voltage up to and
including 600 V/1000 V)
9 Test report (Electric power and control cables
with rated voltage up to and including
600 V/1000 V)
Annex A (informative) - Guidance on the choice of
recommended test equipment
Annex B (normative) - Field of direct application
and extended application of test results
(Electric power and control cables with
rated voltage up to and including
600 V/1000 V)
Annex C (normative) - Fuse characteristic curve
Annex D (informative) - Information regarding
classification
Annex E (informative) - Guidance for using optional
water spray protocol
Bibliography
Defines the test method for cables designed to have intrinsic resistance to fire and intended for use as emergency circuits for alarm, lighting and communication purposes.
| Committee |
GEL/20/18
|
| DevelopmentNote |
Supersedes 96/201661 DC (09/2005) Supersedes BS 8434-1(2003) & 03/310352 DC. (06/2006) Supersedes 13/30282376 DC. (12/2015)
|
| DocumentType |
Standard
|
| Pages |
36
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This European Standard specifies the test method for cables designed to have intrinsic resistance to fire and intended for use as emergency circuits for alarm, lighting and communication purposes. This European Standard is applicable to cables for emergency circuits of rated voltage not exceeding 600V/1000V, including those of rated voltage below 80V and optical fibre cables. This European Standard includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power and control cables with rated voltage up to and including 600V/1000V. Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to copper data and telecom cables and optical cables are given in the relevant standards of CLC/TC 46X and CLC/TC 86A. The test method is limited to cables with an overall diameter not exceeding 20mm. The test method is based on the direct impingement of flame from a propane burner giving a constant temperature attack of a notional 842°C. It is intended to be used for cables for emergency circuits suitable for alarm, emergency lighting and communication. NOTE When the test method is used in support of EN13501‑3 , it only applies to cables of less than 20mm diameter, and, for metallic conductor cables, to those with conductor sizes up to and including 2,5mm 2. For optical cables, only the less than 20mm diameter limit applies. This European Standard includes ( AnnexB) the field of direct application and rules for extended application of test results (EXAP). Details regarding classification using data from this test are given in EN13501‑3 1) . Information regarding classification is given in AnnexD. This European Standard also includes informative guidance ( AnnexE) on a means of applying a water spray to the cable during the test. Such a requirement may be a feature of particular product standards.
| Standards | Relationship |
| NEN EN 50200 : 2015 | Identical |
| NBN EN 50200 : 2016 | Identical |
| NF EN 50200 : 2016 | Identical |
| DIN EN 50200:2016-07 | Identical |
| EN 50200:2015 | Identical |
| I.S. EN 50200:2015 | Identical |
| UNE-EN 50200:2016 | Identical |