BS EN 50265-1:1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable Apparatus
Hardcopy , PDF
English
15-09-1999
18-01-2005
Foreword
1 Scope
2 Normative references
3 Definition
4 Test apparatus
4.1 Components
4.2 Metallic Screen
4.3 Ignition Source
4.4 Chamber
Annex A (informative) Bibliography
Methods of test for resistance to vertical flame propagation for a single electrical insulated conductor or cable, or optical cable, under fire conditions.
| Committee |
GEL/20/18
|
| DevelopmentNote |
Supersedes 95/215049 DC. (03/2007)
|
| DocumentType |
Standard
|
| Pages |
12
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| EN 50265-1:1998 | Identical |
| NF EN 50265-1 : 1999 | Identical |
| NBN EN 50265-1 : 2000 | Identical |
| NEN EN 50265-1 : 1999 | Identical |
| DIN EN 50265-1 : 1999 | Identical |
| I.S. EN 50265-1:1999 | Identical |
| UNE-EN 50265-1:1999 | Identical |
| BS 7870-6.2:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations - XLPE or HEPR insulated and PVC sheathed cables |
| PD 6686:2006 | Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries |
| DEFSTAN 02-517(PT1)/2(2008) : 2008 | REQUIREMENTS FOR CABLE, ELECTRIC - PART 1: PRESSURE-TIGHT ETHYLENE PROPYLENE RUBBER (EPR) OR SILICONE RUBBER INSULATED, CHLOROSULPHONATED POLYETHYLENE (CSP) LIMITED FIRE HAZARD (LFH) SHEATHED |
| DEFSTAN 07-247(PT1)/3(2009) : 2009 | THE SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS - PART 1: SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS |
| BS 7671(2001) : 2001 AMD 14905 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS |
| EN 60695-2-4/1:1993/A1:1996 | FIRE HAZARD TESTING - TEST METHODS - KW NOMINAL PREMIXED TEST FLAME AND GUIDANCE |
| EN 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.