• BS EN 50382-2 : 2008

    Current The latest, up-to-date edition.

    RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2008

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 Scope
    2 Normative references
    3 Definitions
    4 Rated voltage
    5 Marking and identification
    6 Construction of cables
    7 Tests
    Annex A (normative) - Code designation
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: - 1,8/3 kV unscreened, unsheathed with or without textile braid (1,5 mm[2] to 400 mm[2]); - 1,8/3 kV unscreened, sheathed (1,5 mm[2] to 400 mm[2]); - 3,6/6 kV unscreened, unsheathed with or without textile braid (2,5 mm[2] to 400 mm[2]); and - 3,6/6 kV unscreened, sheathed (2,5 mm[2] to 400 mm[2]).

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20/12
    Development Note Supersedes 05/30133183 DC. (05/2008) 2008 Edition is still active and will be withdrawn on 29/04/2016. 2008 Edition Re-Issued in July 2013 and incorporates AMD 1 2013. Supersedes 13/30277645 DC. (08/2013)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 10002-1 : 2001 METALLIC MATERIALS - TENSILE TESTING - PART 1: METHOD OF TEST AT AMBIENT TEMPERATURE
    EN 50266-2-4 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-4: PROCEDURES - CATEGORY C
    IEC 60228:2004 Conductors of insulated cables
    EN 60811-1-3:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
    EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
    EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
    EN 60332-1-2:2004/A11:2016 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015)
    IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
    EN 61034-2:2005/A1:2013 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013)
    HD 308 S2:2001 Identification of cores in cables and flexible cords
    IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
    EN 50305:2002 Railway applications - Railway rolling stock cables having special fire performance - Test methods
    EN 60811-1-2:1995/A2:2000 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS
    IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
    EN 50395 : 2005 AMD 1 2011 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
    EN 60811-2-1 : 98 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 2-1: METHODS SPECIFIC TO ELASTOMERIC COMPOUNDS - OZONE RESISTANCE, HOT SET AND MINERAL OIL IMMERSION TESTS
    IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
    EN 50355:2013 Railway applications - Railway rolling stock cables having special fire performance - Guide to use
    IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
    IEC 60811-2-1:1998+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
    EN 50266-2-5 : 2001 COR 2002 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY- MOUNTED BUNCHED WIRES OR CABLES - PART 2-5: PROCEDURES - SMALL CABLES - CATEGORY D
    IEC 61034-2:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements
    EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
    EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective