BS EN 50600-2-1:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Information technology. Data centre facilities and infrastructures Building construction
Hardcopy , PDF
27-04-2021
English
30-04-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Conformance
5 Location
6 Site configuration
7 Building construction
8 Data centre spaces and access routes
9 Fire compartments, fire barriers and
fire suppression systems
10 Building configurations
Annex A (normative) - Additional requirements
and recommendations
Annex B (informative) - Physical protection against
external hazards
Bibliography
Covers the construction of buildings and other structures which provide accommodation for data centres based upon the criteria and classification for 'physical security' within EN 50600-1 in support of availability.
Committee |
TCT/7
|
DevelopmentNote |
Supersedes 11/30247940 DC. (04/2014)
|
DocumentType |
Standard
|
Pages |
36
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This European Standard addresses the construction of buildings and other structures which provide accommodation for data centres based upon the criteria and classification for “physical security” within EN 50600 1 in support of availability. This European Standard specifies requirements and recommendations for the following: a) location and site selection; b) building construction; c) building configuration; d) fire protection; e) quality construction measures. Safety and electromagnetic compatibility (EMC) requirements are outside the scope of this European Standard and are covered by other standards and regulations. However, information given in this European Standard may be of assistance in meeting these standards and regulations. Conformance of data centres to the present document is covered in Clause 4.
Standards | Relationship |
EN 50600-2-1:2014 | Identical |
EN 12825:2001 | Raised access floors |
EN 50174-1:2009/A2:2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
EN 50174-3:2013/A1:2017 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
EN 15004-1:2008 | Fixed firefighting systems - Gas extinguishing systems - Part 1: Design, installation and maintenance (ISO 14520-1:2006, modified) |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
EN 50600-1:2012 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 1: GENERAL CONCEPTS |
EN 50600-2-4:2015 | Information technology - Data centre facilities and infrastructures - Part 2-4: Telecommunications cabling infrastructure |
PREN 50600-2-5 : DRAFT 2012 | BS EN 50600-2-5 - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS |
PREN 50600-2-3 : DRAFT 2012 | DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-3: ENVIRONMENTAL CONTROL |
ISO 14520-1:2015 | Gaseous fire-extinguishing systems — Physical properties and system design — Part 1: General requirements |
EN 50310:2016 | Telecommunications bonding networks for buildings and other structures |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.