• PREN 50600-2-5 : DRAFT 2012

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    BS EN 50600-2-5 - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS

    Available format(s): 

    Superseded date:  01-03-2016

    Language(s): 

    Published date:  09-11-2012

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 Scope and conformance
    2 Normative references
    3 Definitions and abbreviations
    4 Physical security
    5 Protection Class against unauthorised access
    6 Protection Class against internal fire events
    7 Protection Class against internal environmental
      events (other than fire)
    8 Protection Class against external environmental
      events
    9 Security systems
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines requirements and recommendations for the following: a) the Protection Class to be applied to the spaces within data centres; b) the specified Protection Classes in relation to unauthorised access; c) the specified Protection Classes in relation to internal fire events; d) the specified Protection Classes in relation to internal environmental events excluding fire; e) the specified Protection Classes in relation to external environmental events; f) the security systems to provide the specified Protection Class; g) interfaces between local and remote tools for operational monitoring, control and management of physical security systems and installations.

    General Product Information - (Show below) - (Hide below)

    Comment Closes On
    Committee TC 215
    Document Type Draft
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN 50600-1:2012 Information technology. Data centre facilities and infrastructures General concepts
    EN 50600-1:2012 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 1: GENERAL CONCEPTS
    EN 50600-2-1:2014 Information technology - Data centre facilities and infrastructures - Part 2-1: Building construction
    I.S. EN 50600-2-2:2014 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-2: POWER DISTRIBUTION
    BS EN 50600-2-2:2014 Information technology. Data centre facilities and infrastructures Power distribution
    PREN 50600-2-4 : DRAFT 2013 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-4: TELECOMMUNICATIONS CABLING INFRASTRUCTURE
    I.S. EN 50600-2-1:2014 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-1: BUILDING CONSTRUCTION
    BS EN 50600-2-1:2014 Information technology. Data centre facilities and infrastructures Building construction
    14/30294963 DC : 0 BS EN 50600-2-4 - INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-4: TELECOMMUNICATIONS CABLING INFRASTRUCTURE
    EN 50600-2-2:2014 Information technology - Data centre facilities and infrastructures - Part 2-2: Power distribution

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 1047-1:2005 Secure storage units - Classification and methods of test for resistance to fire - Part 1: Data cabinets and diskette inserts
    EN 1627:2011 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification
    IEC/ISO 31010:2009 Risk management - Risk assessment techniques
    EN 15004-1:2008 Fixed firefighting systems - Gas extinguishing systems - Part 1: Design, installation and maintenance (ISO 14520-1:2006, modified)
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    EN 1047-2:2009+A1:2013 Secure storage units - Classification and methods of test for resistance to fire - Part 2: Data rooms and data container
    EN 31010:2010 Risk management - Risk assessment techniques
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective