BS EN 50600-2-3:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Information technology. Data centre facilities and infrastructures Environmental control
Hardcopy , PDF
24-06-2019
English
31-10-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Conformance
5 Environmental control within data centres
6 Availability
7 Physical security
8 Energy efficiency enablement
Annex A (normative) - Distribution methodologies
for temperature-controlled air in computer
room space
Annex B (informative) - Control system concepts
Bibliography
Defines requirements and recommendations for the following: a) temperature control, b) fluid movement control, c) relative humidity control, d) particulate control, e) vibration, f) floor layout and equipment locations, g) energy saving practices, and h) physical security of environmental control systems.
Committee |
TCT/7
|
DevelopmentNote |
Supersedes 12/30273858 DC. (10/2014)
|
DocumentType |
Standard
|
Pages |
32
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This European Standard addresses environmental control within data centres based upon the criteria and classifications for “availability”, “security” and “energy efficiency enablement” within EN 50600-1. This European Standard specifies requirements and recommendations for the following: temperature control, fluid movement control, relative humidity control, particulate control, vibration, floor layout and equipment locations, energy saving practices, physical security of environmental control systems. For issues related to electromagnetic environment, see EN 50600-2-5.
Standards | Relationship |
EN 50600-2-3:2014 | Identical |
ETS 300 119-1 : 20001 | EQUIPMENT ENGINEERING (EE); EUROPEAN TELECOMMUNICATION STANDARD FOR EQUIPMENT PRACTICE - INTRODUCTION AND TERMINOLOGY |
EN 50600-2-1:2014 | Information technology - Data centre facilities and infrastructures - Part 2-1: Building construction |
EN 12792:2003 | Ventilation for buildings - Symbols, terminology and graphical symbols |
IEC 60050-212:2010 | International Electrotechnical Vocabulary (IEV) - Part 212: Electrical insulating solids, liquids and gases |
PREN ISO 14644-2 : DRAFT 2010 | CLEANROOMS AND ASSOCIATED CONTROLLED ENVIRONMENTS - PART 2: SPECIFICATIONS FOR MONITORING AND PERIODIC TESTING TO PROVE CONTINUED COMPLIANCE WITH ISO 14644-1 |
ETS 300 119-3 : 20001 | EQUIPMENT ENGINEERING (EE); EUROPEAN TELECOMMUNICATION STANDARD FOR EQUIPMENT PRACTICE - ENGINEERING REQUIREMENTS FOR MISCELLANEOUS RACKS AND CABINETS |
EN 779:2012 | Particulate air filters for general ventilation - Determination of the filtration performance |
PREN ISO 14644-1 : DRAFT 2010 | CLEANROOMS AND ASSOCIATED CONTROLLED ENVIRONMENTS - PART 1: CLASSIFICATION OF AIR CLEANLINESS BY PARTICLE CONCENTRATION |
EN 50600-1:2012 | INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 1: GENERAL CONCEPTS |
EN 50600-2-5:2016 | Information technology - Data centre facilities and infrastructures - Part 2-5: Security systems |
EN 50600-2-4:2015 | Information technology - Data centre facilities and infrastructures - Part 2-4: Telecommunications cabling infrastructure |
EN 50272-2:2001 | Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries |
ETS 300 119-2 : 20001 | EQUIPMENT ENGINEERING (EE); EUROPEAN TELECOMMUNICATION STANDARD FOR EQUIPMENT PRACTICE - ENGINEERING REQUIREMENTS FOR RACKS AND CABINETS |
EN 15243:2007 | Ventilation for buildings - Calculation of room temperatures and of load and energy for buildings with room conditioning systems |
IEC 60050-705:1995 | International Electrotechnical Vocabulary (IEV) - Part 705: Radio wave propagation |
EN 378-2:2016 | Refrigerating systems and heat pumps - Safety and environmental requirements - Part 2: Design, construction, testing, marking and documentation |
ETS 300 119-4 : 20001 | EQUIPMENT ENGINEERING (EE); EUROPEAN TELECOMMUNICATION STANDARD FOR EQUIPMENT PRACTICE - ENGINEERING REQUIREMENTS FOR SUBRACKS IN MISCELLANEOUS RACKS AND CABINETS |
ETS 300 200019-1-3 : 20001 | EQUIPMENT ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT - CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - STATIONARY USE AT WEATHERPROTECTED LOCATIONS |