BS EN 55016-1-5:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus. Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
Hardcopy , PDF
02-10-2020
English
28-02-2015
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Specifications and validation procedures
for CALTS and REFTS from 5 MHz to
1000 MHz
5 Validation methods for a FAR from
30 MHz to 18 GHz
6 Validation methods for sites used for
the calibration of directive antennas
7 Site validation by comparison of antenna
factors, and application of RSM to evaluate
the uncertainty contribution of a SAC site
Annex A (informative) - CALTS characteristics
and validation
Annex B (informative) - Test antenna considerations
Annex C (informative) - Antenna and SIL theory
Annex D (informative) - Pascal Program used in C.1.4
Annex E (informative) - Validation procedure checklist
Annex F (informative) - Evidence that field taper of VP
site validation method has negligible effect on
measured antenna factor
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6.
Committee |
GEL/210/11
|
DevelopmentNote |
Together with BS EN 55016-1-1, BS EN 55016-1-2, BS EN 55016-1-3 and BS EN 55016-1-4 it supersedes BS CISPR 16-1(1999). 2004 Edition is still active & will be withdrawn on 24-07-2015. Supersedes 09/30208075 DC. (02/2013) 2004 + A1 2012 Edition remains active & will be withdrawn on 21/01/2018. (02/2015)
|
DocumentType |
Standard
|
Pages |
102
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
CISPR 16-1-5:2014 specifies the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6. It also specifies the requirements for reference test sites that are used for the validation of compliance test sites in the frequency range 30 MHz to 1 000 MHz according to CISPR 16-1-4. It has the status of a basic EMC standard in accordance with IEC Guide 107. Measurement instrumentation specifications are given in CISPR 16-1-1 and CISPR 16-1-4. Further information and background on uncertainties in general is given in CISPR 16-4, which can also be helpful in establishing uncertainty estimates for the calibration processes of antennas and site validation measurements. This second edition cancels and replaces the first edition published in 2003, and its Amendment 1 (2012). It constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:
- site validation methods for other sites covered in CISPR 16-1-6 are added;
- smaller step sizes are specified for swept frequency measurements;
- the minimum ground plane size is increased;
- and other miscellaneous technical and editorial refinements are included. Keywords: electromagnetic compatibility
Standards | Relationship |
CISPR 16-1-5:2014+AMD1:2016 CSV | Identical |
EN 55016-1-5:2015/A1:2017 | Identical |
NEN EN 55016-1-5 : 2015 AMD 1 2017 | Identical |
DIN EN 55016-1-5 : 2015 | Identical |
NF EN 55016-1-5 : 2015 AMD 1 2017 | Identical |
I.S. EN 55016-1-5:2015 | Identical |
CISPR 16-1-5:2014 | Identical |
EN 55016-1-6:2015/A1:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-6: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - EMC ANTENNA CALIBRATION (CISPR 16-1-6:2014/A1:2017) |
EN 55016-1-4:2010/A2:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
ANSI C63.5 : 2006 | ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ) |
IEEE/ANSI C63.7-2015 | American National Standard Guide for Construction of Test Sites for Performing Radiated Emission Measurements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.