• EN 55016-1-6:2015/A1:2017

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-6: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - EMC ANTENNA CALIBRATION (CISPR 16-1-6:2014/A1:2017)

    Available format(s): 

    Superseded date:  03-05-2022

    Language(s): 

    Published date:  26-05-2017

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope
    2 Normative references
    3 Terms, definitions and abbreviations
    4 Fundamental concepts
    5 Calibration methods for the frequency
      range 9 kHz to 30 MHz
    6 Frequencies, equipment and functional
      checks for calibrations at or above 30 MHz
    7 Basic parameters and equations common
      to antenna calibration methods for frequencies
      above 30 MHz
    8 Details for TAM, SAM, and SSM calibration
      methods for frequencies of 30 MHz and above
    9 Calibration procedures for specific antenna
      types for frequencies of 30 MHz and above
    Annex A (informative) - Background information
            and rationale for the methods of antenna
            calibration
    Annex B (normative) - Calibration of biconical
            antennas and tuned dipole antennas above
            a ground plane using the TAM and the SAM
    Annex C (informative) - Rationale for the equations
            used in antenna calibration and relevant
            information about antenna characteristics for
            uncertainty analysis in the frequency range 30
            MHz to 1 GHz
    Annex D (informative) - Background information
            and rationale for calibration of antennas at
            frequencies above 1 GHz
    Annex E (informative) - Notes for measurement
            uncertainty budgets
    Annex F (informative) - Mismatch uncertainties
            from a two-port device connected between a
            transmit port and a receive port
    Annex G (informative) - Verification method for
            calibration of monopole antennas and
            uncertainty analysis of the ECSM
    Annex H (informative) - Helmholtz coil method for
            calibration of loop antennas up to 150 kHz
    Annex I (normative) - Antenna pattern measurement
            method in the frequency range above 1 GHz, with
            measurement uncertainty budget
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    Gives procedures and supporting information for the calibration of antennas for determining antenna factors (AF) that are applicable to antennas intended for use in radiated disturbance measurements.

    General Product Information - (Show below) - (Hide below)

    Committee TC 210
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    EN 55016-1-4:2010/A2:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017)
    UNE-EN 55016-1-4:2011 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements
    BS EN 55016-1-5:2015 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus. Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
    I.S. EN 55016-1-4:2010 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS
    BS EN 55016-1-4 : 2010 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017)
    I.S. EN 55016-1-5:2015 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-5: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNA CALIBRATION SITES AND REFERENCE TEST SITES FOR 5 MHZ TO 18 GHZ
    EN 55016-1-5:2015/A1:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-5: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNA CALIBRATION SITES AND REFERENCE TEST SITES FOR 5 MHZ TO 18 GHZ (CISPR 16-1-5:2014/A1:2016)

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-22:2010 Electromagnetic compatibility (EMC) - Part 4-22: Testing and measurement techniques - Radiated emissions and immunity measurements in fully anechoic rooms (FARs)
    CISPR 16-4-2:2011+AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
    EN 55016-1-4:2010/A2:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017)
    CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements
    CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
    IEEE 1309-2013 REDLINE IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes (Excluding Antennas) from 9 kHz to 40 GHz
    CISPR 16-1-5:2014+AMD1:2016 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
    CISPR 25:2016 Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
    EN 55016-1-5:2015/A1:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-5: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNA CALIBRATION SITES AND REFERENCE TEST SITES FOR 5 MHZ TO 18 GHZ (CISPR 16-1-5:2014/A1:2016)
    ISO/IEC 17043:2010 Conformity assessment — General requirements for proficiency testing
    MIL-STD-461 Revision G:2015 REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT
    IEC 61169-16:2006 Radio-frequency connectors - Part 16: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 7 mm (0,276 in) with screw coupling - Characteristics impedance 50 ohms (75 ohms) (type N)
    CISPR 16-2-3:2016 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
    ANSI C63.5 : 2006 ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ)
    IEC 60050-726:1982 International Electrotechnical Vocabulary (IEV) - Part 726: Transmission lines and waveguides
    IEEE 1128-1998 IEEE Recommended Practice for Radio-Frequency (RF) Absorber Evaluation in the Range of 30 MHz to 5 GHz
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective