1 Scope
2 Normative references
3 Definitions
4 Electromagnetic environment
5 Disturbing phenomena
6 Immunity requirements
7 Testing
8 Documentation for the purchaser/user
Annex A (normative) - Method of measurement of
immunity to radiated magnetic fields,
50 Hz to 10 kHz
Annex B (normative) - Methods of measurement
of common mode immunity for balanced
signal and control ports intended to be
connected to cables whose total length
according to the manufacturer's specification
may exceed 10 m; 50 Hz to 10 kHz
Annex C (informative) - Apparatus using infra-red
radiation for open-air transmission purposes
Annex D (informative) - Guidance for test houses
on immunity testing of audio, video, audio-visual
and entertainment lighting control apparatus
for professional use
Annex E (informative) - Background information
about this standard
Annex ZZ (informative) - Coverage of Essential
Requirements of EC Directives
Bibliography
National Annex NA (informative) - Text of IS1 to E
N 55103-2:2009
Pertains to professional audio, video, audio-visual and entertainment lighting control apparatus as defined in 3.6 intended for use in the environments described in Clause 4.
Committee |
GEL/210
|
DevelopmentNote |
Supersedes 95/207380 DC (07/2004) Supersedes 11/30248811 DC. (07/2012)
|
DocumentType |
Standard
|
Pages |
40
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This European Standard for EMC immunity requirements applies to professional audio, video, audio-visual andentertainment lighting control apparatusas defined in 3.6 intended for use in the environmentsdescribed in Clause 4. Thisincludes the digital apparatus definedin 3.5 and sub-assemblies, see 7.4.
Disturbances in the frequency range 0 Hz to 400 GHz are covered, but requirements are not establishedover the whole of that range.
NOTE 1 In Annex C, information is included on infra-red radiation in the wavelength range 0,7 μm to 1,6 μm.
The objective of this standard is to define the immunity test requirements, test signals, performance criteria and test methods for apparatus defined in the scope, in relation to electromagnetic immunity to continuous and transient conducted and radiated electromagnetic disturbances including electrostatic discharges. These test requirements represent essential electromagnetic compatibility requirements.
Fault conditions of source or victim apparatus are not taken into account.
Apparatus asdefined in 3.4, 3.5 and 3.6 may be operated with any source of power.
NOTE 2 Sources of power may include, for example: the publiclow-voltage supply; private supplies with similar characteristics; ad.c. source provided specifically for the apparatus; batteries internal to the apparatus; stand-by generators. Some standards may not apply to private low-voltage supplies.
NOTE 3 If it is intended to use a hand-held transmitter in proximity, additional mitigation measures may have to be employed to increase the electromagnetic immunity further, beyond the specified limits.
This European Standard does not apply to
consumer apparatus,
apparatus specifically designed for security systems,
apparatus designed to radiate electromagnetic energy for radio communications purposes.
Standards | Relationship |
EN 55103-2:2009 | Identical |
UNE-EN 55103-2:2010 | Identical |
DIN EN 55103-2 : 2010 | Identical |
NBN EN 55103-2 : 2009 | Identical |
SN EN 55103-2 : 2009 | Identical |
I.S. EN 55103-2:2009 | Identical |
NF EN 55103-2 : 2009 | Identical |
EN 55103-2:2009/IS1:2012 | Identical |
IEC 60332-3-10:2018 | Identical |
IEC 60332-3-10:2018/COR1:2018 | Identical |
EN IEC 60332-3-10:2018 | Identical |
NEN EN 55103-2 : 2009 | Identical |
CISPR 20:2006+AMD1:2013 CSV | Sound and television broadcast receivers and associated equipment -Immunity characteristics - Limits and methods of measurement |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 55020:2007/A12:2016 | SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 20:2006) |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
HD 483.1 : 200S2 | SOUND SYSTEM EQUIPMENT - GENERAL |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
IEC 60268-1:1985 | Sound system equipment. Part 1: General |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
EN 55103-1:2009/A1:2012 | ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR AUDIO, VIDEO, AUDIO-VISUAL AND ENTERTAINMENT LIGHTING CONTROL APPARATUS FOR PROFESSIONAL USE - PART 1: EMISSIONS |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.