1 Scope and object
2 Normative references
3 Functional characteristics
  3.1 Capacity
  3.2 Charge retention
  3.3 High-rate discharge performance
  3.4 Cyclic endurance
4 General test conditions
  4.1 Accuracy of measuring instruments
  4.2 Preparation and maintenance of the test cells or
      batteries
  4.3 Characteristics of a fully charged cell or battery
      (unless the state of a fully charged battery is
      otherwise stated by the manufacturer)
5 Testing procedure
  5.1 Sequence of performance of the tests
  5.2 Capacity test
  5.3 Charge retention test
  5.4 High-rate discharge performance test
  5.5 Cyclic endurance test
6 Specific values
  6.1 Energy density
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications
Bibliography

Applies to lead-acid traction batteries for use as power sources for electric propulsion.

Committee
PEL/21
DevelopmentNote
Together with BS EN 60254-2, it supersedes BS 2550(1983) (06/2002) Supersedes BS 7483(1991). (09/2007)
DocumentType
Standard
Pages
18
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of IEC 60254 is applicable to lead-acid traction batteries used as power sources for electric propulsion.

The tests defined are relevant to all traction battery applications which include road vehicles, locomotives, industrial trucks and mechanical handling equipments. Tests which may be used specifically to test batteries developed for use in vehicles such as light passenger vehicles, motor cycles, light commercial vehicles, etc. may be found in alternative standards e.g. IEC 61982-2.

The object of this standard is to specify certain essential characteristics of traction batteries or cells, together with the relevant test methods of those characteristics.

Although Part 2 of this standard defines dimensions of commonly used traction cells, the tests in Part 1 may be applied to cells and monobloc batteries of other dimensions, if the application is appropriate.

Standards Relationship
IEC 60254-1:2005 Identical
EN 60254-1:2005 Identical
SN EN 60254-1 : 1997 Identical
NBN EN 60254-1 : 2005 Identical
NF EN 60254-1 : 2005 Identical
I.S. EN 60254-1:2005 Identical
UNE-EN 60254-1:2005 Identical
DIN EN 60254-1:2006-01 Identical

IEC 61982-2:2002 Secondary batteries for the propulsion of electric road vehicles - Part 2: Dynamic discharge performance test and dynamic endurance test
IEC 60050-482:2004 International Electrotechnical Vocabulary (IEV) - Part 482: Primary and secondary cells and batteries
EN 60254-2:2008 Lead-acid traction batteries - Part 2: Dimensions of cells and terminals and marking of polarity on cells

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.