Excluding VAT

1 Scope
2 Normative references
3 Conditions
4 Classes of operation
5 Interchangeable parts
6 Automatic controls
7 Power supply
8 Position of the volume controls
9 Pre-conditioning for measurements
10 Series of measurements
11 Variable consumption apparatus
12 Marking
13 Operating environment
14 Characteristics to be specified, and their methods
   of measurement
Annex A (informative) - Balanced interfaces
Annex B (informative) - Specification of a multi-channel
        amplifier
Bibliography
Annex ZA (normative) - Normative references to
         international Publications with their
         corresponding European publications

Pertains to analogue amplifiers, and the analogue parts of analogue/digital amplifiers, which form part of a sound system for professional or household applications.

Committee
EPL/100
DevelopmentNote
Supersedes BS 6840-3(1992) (04/2001) Supersedes 96/211067 DC. (09/2005)
DocumentType
Standard
Pages
64
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

This part of IEC 60268 applies to analogue amplifiers, and the analogue parts of analogue/digital amplifiers, which form part of a sound system for professional or household applications. It specifies the characteristics which should be included in specifications of amplifiers and the corresponding methods of measurement.

NOTE The methods of measurement for digital amplifiers and similar equipment are given in IEC 61606 [4] 1.

In general, the specified methods of measurement are those which are seen to be most directly related to the characteristics. This does not exclude the use of other methods which give equivalent results.

In general, the methods are based on the simplest measuring equipment which can provide useful results. This does not exclude the use of more complex equipment which can give higher accuracy and/or allow automatic measurement and recording of results.

Rated conditions and standard measuring conditions are specified in order to allow measurements to be reliably repeated.

Standards Relationship
UNE-EN 60268-3:2002 Identical
SN EN 60268-3 : 2000 Identical
DIN EN 60268-3:2014-03 Identical
IEC 60268-3:2013 Identical
NBN EN 60268-3 : 2013 Identical
EN 60268-3:2013 Identical
NF EN 60268-3 : 2014 Identical
I.S. EN 60268-3:2013 Identical

BS 6259:2015 Code of practice for the design, planning, installation, testing and maintenance of sound systems
13/30218906 DC : 0 BS 6259 - CODE OF PRACTICE FOR THE DESIGN, PLANNING, INSTALLATION, TESTING AND MAINTENANCE OF SOUND SYSTEMS
BS 7827:2011 Code of practice for designing, specifying, maintaining and operating emergency sound systems at sports venues

EN 60065:2014/AC:2017-01 AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016)
IEC 61000-4-17:1999+AMD1:2001+AMD2:2008 CSV Electromagnetic compatibility (EMC) - Part 4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test
IEC 61938:2013 Multimedia systems - Guide to the recommended characteristics of analogue interfaces to achieve interoperability
HD 483.1 : 200S2 SOUND SYSTEM EQUIPMENT - GENERAL
IEC 60268-1:1985 Sound system equipment. Part 1: General
IEC 60098:1987 Analogue audio disk records and reproducing equipment
IEC 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
EN 61000-4-17:1999/A2:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-17: TESTING AND MEASUREMENT TECHNIQUES - RIPPLE ON D.C. INPUT POWER PORT IMMUNITY TEST
EN 61000-4-13:2002/A2:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015)
HD 483.2 : 200S2 SOUND SYSTEM EQUIPMENT - EXPLANATION OF GENERAL TERMS AND CALCULATION METHODS
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
EN 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 60268-5:2003+AMD1:2007 CSV Sound system equipment - Part 5: Loudspeakers

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.