• There are no items in your cart

BS EN 60420:1993

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Specification for high-voltage alternating current switch-fuse combinations

Available format(s)

Hardcopy , PDF

Withdrawn date

27-10-2018

Language(s)

English

Published date

28-02-1991

€306.17
Excluding VAT

Committees responsible
National foreword
Specification
1 General
2 Normal and special service conditions
3 Definitions
4 Rating
5 Design and construction
6 Type tests
7 Routine tests
8 Application guide for the selection of switch-fuse
      combinations for service
9 Information to be given with enquiries, tenders
      and orders
10 Rules for transport, storage, erection and
      maintenance
Appendices
A Example of the co-ordination of fuses, switch and
      transformer
B Justification of the procedure for determining
      transfer current and of the parameters associated
      with test duty 4
Tables
I Standard values of rated TRV (Based on practice in
      Europe)
IA Standard values of rated TRV (Based on practice in
      the United States of America and Canada)
II Nameplate markings
III Standard values of prospective TRV for test duty 2
      (Based on practice in Europe)
IIIA Standard values of prospective TRV for test duty 2
      (Based on practice in the United States of America
      and Canada)
IV Standard values of prospective TRV for test duty 4
      (Based on practice in Europe)
IVA Standard values of prospective TRV for test duty 4
      (Based on practice in the United States of America
      and Canada)
V Summary of test parameters for test duties 1 to 5
Annex
ZA Other International publications quoted in this
      standard with the references of the relevant
      European publications
Figures
1 Representation of a specified TRV by a two-
      parameter reference line and a delay line
2 Example of a two-parameter reference line for a
      TRV
3 Arrangement of test circuits for test duties 1 and
      2
4 Arrangement of test circuits for test duty 3
5 Arrangement of test circuits for test duties 4 and
      5
6 Determination of power-frequency recovery voltage
7 Practical determination of transfer current
8 Probable maximum and minimum time-current
      characteristics of fuse
9 Transfer current in relation to the primary fault
      current Isc due to a solid short in the
      transformer secondary terminal
10 Characteristics relating to the protection of an
      11 kV - 400 kVA transformer
11 Discrimination between HV and LV fuses
12 Characteristics for determining take-over current

Requirements for three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses.

Committee
PEL/17
DevelopmentNote
Supersedes and renumbers BS 7426(1991) (07/2004)
DocumentType
Standard
Pages
68
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
UNE-EN 60420:1997 Identical
NF EN 60420 : 1993 Identical
IEC 60420:1990 Identical
NBN EN 60420 : 1995 Identical
I.S. EN 60420:1994 Identical
SN EN 60420 : 1993 Identical
EN 60420:1993 Identical
DIN EN 60420 : 1994 Identical

BS 2692-1(1996) : 1996 HIGH-VOLTAGE FUSES - CURRENT-LIMITING FUSES

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.