BS EN 60420:1993
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Specification for high-voltage alternating current switch-fuse combinations
Hardcopy , PDF
27-10-2018
BS EN 62271-105:2003
BS EN 62271-105:2012
BS EN 61340-5-1:2001
English
28-02-1991
Committees responsible
National foreword
Specification
1 General
2 Normal and special service conditions
3 Definitions
4 Rating
5 Design and construction
6 Type tests
7 Routine tests
8 Application guide for the selection of switch-fuse
combinations for service
9 Information to be given with enquiries, tenders
and orders
10 Rules for transport, storage, erection and
maintenance
Appendices
A Example of the co-ordination of fuses, switch and
transformer
B Justification of the procedure for determining
transfer current and of the parameters associated
with test duty 4
Tables
I Standard values of rated TRV (Based on practice in
Europe)
IA Standard values of rated TRV (Based on practice in
the United States of America and Canada)
II Nameplate markings
III Standard values of prospective TRV for test duty 2
(Based on practice in Europe)
IIIA Standard values of prospective TRV for test duty 2
(Based on practice in the United States of America
and Canada)
IV Standard values of prospective TRV for test duty 4
(Based on practice in Europe)
IVA Standard values of prospective TRV for test duty 4
(Based on practice in the United States of America
and Canada)
V Summary of test parameters for test duties 1 to 5
Annex
ZA Other International publications quoted in this
standard with the references of the relevant
European publications
Figures
1 Representation of a specified TRV by a two-
parameter reference line and a delay line
2 Example of a two-parameter reference line for a
TRV
3 Arrangement of test circuits for test duties 1 and
2
4 Arrangement of test circuits for test duty 3
5 Arrangement of test circuits for test duties 4 and
5
6 Determination of power-frequency recovery voltage
7 Practical determination of transfer current
8 Probable maximum and minimum time-current
characteristics of fuse
9 Transfer current in relation to the primary fault
current Isc due to a solid short in the
transformer secondary terminal
10 Characteristics relating to the protection of an
11 kV - 400 kVA transformer
11 Discrimination between HV and LV fuses
12 Characteristics for determining take-over current
Requirements for three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses.
Committee |
PEL/17
|
DevelopmentNote |
Supersedes and renumbers BS 7426(1991) (07/2004)
|
DocumentType |
Standard
|
Pages |
68
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 60420:1997 | Identical |
NF EN 60420 : 1993 | Identical |
IEC 60420:1990 | Identical |
NBN EN 60420 : 1995 | Identical |
I.S. EN 60420:1994 | Identical |
SN EN 60420 : 1993 | Identical |
EN 60420:1993 | Identical |
DIN EN 60420 : 1994 | Identical |
BS 2692-1(1996) : 1996 | HIGH-VOLTAGE FUSES - CURRENT-LIMITING FUSES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.