• EN 60420:1993

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    High-voltage alternating current switch-fuse combinations

    Available format(s): 

    Superseded date:  01-05-2003

    Language(s): 

    Published date:  30-08-1993

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    National foreword
    Specification
    1 General
    2 Normal and special service conditions
    3 Definitions
    4 Rating
    5 Design and construction
    6 Type tests
    7 Routine tests
    8 Application guide for the selection of switch-fuse
          combinations for service
    9 Information to be given with enquiries, tenders
          and orders
    10 Rules for transport, storage, erection and
          maintenance
    Appendices
    A Example of the co-ordination of fuses, switch and
          transformer
    B Justification of the procedure for determining
          transfer current and of the parameters associated
          with test duty 4
    Tables
    I Standard values of rated TRV (Based on practice in
          Europe)
    IA Standard values of rated TRV (Based on practice in
          the United States of America and Canada)
    II Nameplate markings
    III Standard values of prospective TRV for test duty 2
          (Based on practice in Europe)
    IIIA Standard values of prospective TRV for test duty 2
          (Based on practice in the United States of America
          and Canada)
    IV Standard values of prospective TRV for test duty 4
          (Based on practice in Europe)
    IVA Standard values of prospective TRV for test duty 4
          (Based on practice in the United States of America
          and Canada)
    V Summary of test parameters for test duties 1 to 5
    Annex
    ZA Other International publications quoted in this
          standard with the references of the relevant
          European publications
    Figures
    1 Representation of a specified TRV by a two-
          parameter reference line and a delay line
    2 Example of a two-parameter reference line for a
          TRV
    3 Arrangement of test circuits for test duties 1 and
          2
    4 Arrangement of test circuits for test duty 3
    5 Arrangement of test circuits for test duties 4 and
          5
    6 Determination of power-frequency recovery voltage
    7 Practical determination of transfer current
    8 Probable maximum and minimum time-current
          characteristics of fuse
    9 Transfer current in relation to the primary fault
          current Isc due to a solid short in the
          transformer secondary terminal
    10 Characteristics relating to the protection of an
          11 kV - 400 kVA transformer
    11 Discrimination between HV and LV fuses
    12 Characteristics for determining take-over current

    Abstract - (Show below) - (Hide below)

    This standard applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses and thus able to interrupt: -any load current up to the rated breaking current of the switch; -any over-current up to the rated short-circuit breaking current of the combination by which automatic interruption is initiated. This standard applies to combinations designed with rated voltages above 1 kV and below 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 17AC
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    DIN EN 45510-2-7:2003-12 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    EN 60204-11:2000/corrigendum:2010 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
    BS EN 45510-2-7:2002 Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear
    CEI EN 60265-1 : 2000 INTERRUPTEURS A HAUTE TENSION - PARTIE 1: INTERRUPTEURS POUR TENSIONS ASSIGNEES SUPERIEURES A 1 KV ET INFERIEURES A 52 KV
    CEI UNI EN 45510-2-7 : 2006 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    BS EN 60204-11 : 2001 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
    I.S. EN 60204-11:2000 SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES PART 11: REQUIREMENTS FOR HV EQUIPMENT FOR VOLTAGES ABOVE 1000 V A.C. OR 1500 V D.C. AND NOT EXCEEDING 36 KV
    UNI CEI EN 45510-2-7 : 2011 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    I.S. EN 45510-2-7:2002 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
    EN 45510-2-7:2002 Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear
    BS EN 60265-1:1998 Specification for high-voltage switches Switches for rated voltages above 1 kV and less than 52 kV
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective