• BS EN 60420:1993

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Specification for high-voltage alternating current switch-fuse combinations

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  27-10-2018

    Language(s):  English

    Published date:  28-02-1991

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    National foreword
    Specification
    1 General
    2 Normal and special service conditions
    3 Definitions
    4 Rating
    5 Design and construction
    6 Type tests
    7 Routine tests
    8 Application guide for the selection of switch-fuse
          combinations for service
    9 Information to be given with enquiries, tenders
          and orders
    10 Rules for transport, storage, erection and
          maintenance
    Appendices
    A Example of the co-ordination of fuses, switch and
          transformer
    B Justification of the procedure for determining
          transfer current and of the parameters associated
          with test duty 4
    Tables
    I Standard values of rated TRV (Based on practice in
          Europe)
    IA Standard values of rated TRV (Based on practice in
          the United States of America and Canada)
    II Nameplate markings
    III Standard values of prospective TRV for test duty 2
          (Based on practice in Europe)
    IIIA Standard values of prospective TRV for test duty 2
          (Based on practice in the United States of America
          and Canada)
    IV Standard values of prospective TRV for test duty 4
          (Based on practice in Europe)
    IVA Standard values of prospective TRV for test duty 4
          (Based on practice in the United States of America
          and Canada)
    V Summary of test parameters for test duties 1 to 5
    Annex
    ZA Other International publications quoted in this
          standard with the references of the relevant
          European publications
    Figures
    1 Representation of a specified TRV by a two-
          parameter reference line and a delay line
    2 Example of a two-parameter reference line for a
          TRV
    3 Arrangement of test circuits for test duties 1 and
          2
    4 Arrangement of test circuits for test duty 3
    5 Arrangement of test circuits for test duties 4 and
          5
    6 Determination of power-frequency recovery voltage
    7 Practical determination of transfer current
    8 Probable maximum and minimum time-current
          characteristics of fuse
    9 Transfer current in relation to the primary fault
          current Isc due to a solid short in the
          transformer secondary terminal
    10 Characteristics relating to the protection of an
          11 kV - 400 kVA transformer
    11 Discrimination between HV and LV fuses
    12 Characteristics for determining take-over current

    Abstract - (Show below) - (Hide below)

    Requirements for three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses.

    General Product Information - (Show below) - (Hide below)

    Committee PEL/17
    Development Note Supersedes and renumbers BS 7426(1991) (07/2004)
    Document Type Standard
    Publisher British Standards Institution
    Status Withdrawn
    Superseded By
    Supersedes