• There are no items in your cart

BS EN 60444-1:1997

Current

Current

The latest, up-to-date edition.

Measurement of quartz crystal unit parameters Basic method for the measurement of resonance frequency and resonance resistance of quartz crystal units by zero phase technique in a π-network

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-08-2000

€217.36
Excluding VAT

Committees responsible
National foreword
Foreword
1 Scope
2 Definition of resonance frequency
3 Reference plane and shielding box
4 Principle of measurement
5 Measuring circuit
      5.1 The p-network
      5.2 Accessories of the p-network
      5.3 Associated equipment
6 Method of measurement
      6.1 Initial calibration of the p-network
      6.2 Frequency and resistance measurement
Appendix A - Additional information on accuracy
Annex B (normative) updating of some formulae of Appendix A
Figure 1
Figure 2
Figure 3 - Plot showing the phase change from the value at
           25 O versus reference resistor values from 0 to
           100 O AT 10 MHz, 50 MHz, 100 MHz and 200 MHz.
           Measuring circuit according to, Figure 1 page 4
Figure 4 - Reference resistors and shorting blank
Figure 5a
Figure 5a
Figure A.1
Figure A.2
Figure A.3
Figure A.4
Figure A.5
Figure A.6
Figure A.7
Figure A.8 - A typical phase/frequency variation of an
             adjusted p-network with a 25 O reference
             resistor
Figure A.9 - Typical p-network
Figure A.10 - Detail of network assembly
Figure A.11 - Dimensions of contacting plates and earthed
              shield; x indicates position of rod and disk
              centers of p-network
Figure A.12 - Position of the reference resistor with
              respect to the network contacting plates
Figure A.13 - Other design of a p-network

Defines a simple method for measuring resonance frequency and resonance resistance of quartz crystal units, and establishes a suitable measuring network.

Committee
W/-
DevelopmentNote
Renumbers and supersedes BS 7681-1(1993). 1997 version incorporates amendment 9657 to BS 7681-1(1993). Also numbered as IEC 60444-1. Supersedes 97/202227 DC. (04/2005)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Current
Supersedes

BS EN 60444-2:1997 Measurement of quartz crystal unit parameters Phase offset method for measurement of motional capacitance of quartz crystal units
BS EN 60444-4:1997 Measurement of quartz crystal unit parameters Method for the measurement of the load resonance frequency <i>f</i><sub>L</sub>, load resonance resistance <i>R</i><sub>L</sub> and the calculation of other derived values of quartz crystal units, up to 30 MHz

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.