BS EN 60517:1997
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
Hardcopy , PDF
27-10-2018
BS EN 62271-203:2012
BS EN 62271-203:2004
BS EN 61340-5-1:2001
English
15-06-2001
Committees responsible
National foreword
Foreword
1 Scope
2 Normal and special service conditions
3 Definitions
4 Rating
4.1 Rated voltage
4.2 Rated insulation level
4.3 Rated frequency
4.4 Rated normal current and temperature rise
4.5 Rated short-time withstand current
4.6 Rated peak withstand current
4.7 Rated duration of short-circuit
4.8 Rated supply voltage of closing and opening
devices and auxiliary circuits
4.9 Rated supply frequency of operating devices and
auxiliary circuits
4.10 Rated pressure of compressed gas supply for
operating mechanisms
4.101 Rated density of gas for insulation
5 Design and construction
5.1 Requirements for liquids in switchgear and
controlgear
5.2 Requirements for gases in switchgear and
controlgear
5.3 Earthing
5.4 Auxiliary equipment
5.5 Dependent power closing
5.6 Stored energy closing
5.7 Operation of releases
5.8 Low and high pressure interlocking devices
5.9 Nameplates
5.101 Degree of protection
5.102 Internal fault
5.103 Enclosures
5.104 Partitions
5.105 Pressure relief
5.106 Disconnectors and earthing switches
5.107 Interlocks
5.108 Noise
5.109 Provisions for dielectric tests on cables
6 Type tests
6.1 Dielectric tests
6.2 Radio interference voltage (RIV) tests
6.3 Temperature-rise tests
6.4 Measurement of the resistance of the main circuit
6.5 Short-time and peak withstand current tests
6.101 Verification of making and breaking capacities
6.102 Mechanical operation tests
6.103 Verification of the degree of protection for
auxiliary circuits and moving parts
6.104 Proof tests for enclosures
6.105 Weatherproofing test
6.106 Test under conditions of arcing due to an
internal fault
6.107 Thermal stability test
6.108 Operation tests at limit temperatures
6.109 Gas tightness tests
7 Routine tests
7.1 Power-frequency voltage tests on the main circuit
7.2 Dielectric tests on auxiliary and control
circuits
7.3 Measurement of the resistance of the main circuit
7.101 Partial discharge measurement
7.102 Pressure tests of enclosures
7.103 Gas tightness tests
7.104 Mechanical operation tests
7.105 Tests of auxiliary electrical, pneumatic and
hydraulic devices
7.106 Verification of the correct wiring
7.107 Tests after erection on site
8 Guide to the selection of the switchgear for
service
National annex NA (informative)
Requirements for indoor or outdoor switchgear utilising gas other than air at atmospheric pressure for insulation for a.c. rated voltages of 7.2 kV upwards at frequencies up to and including 60 Hz.
Committee |
PEL/17
|
DevelopmentNote |
Supersedes 87/21834 DC. Also numbered as IEC 60517. (06/2001) Renumbers and supersedes BS 5524(1992). 1997 version incorporates amendment 9211 to BS 5524(1992). Supersedes 93/200463 DC. (04/2005)
|
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE EN 60517 : 1998 A11 2000 | Identical |
NF EN 60517 : 96 AMD 11 2001 | Identical |
NBN EN 60517 : 96 AMD 1 2000 | Identical |
I.S. EN 60517:AMD 11 2000 | Identical |
SN EN 60517 : 1996 AMD 11 1999 | Identical |
EN 60517:1996/A11:1999 | Identical |
IEC 60517:1990 | Identical |
IEC 60480:2004 | Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
BS EN 60137:2008 | Insulated bushings for alternating voltages above 1000 V |
BS EN 60651:1994 | Specification for sound level meters |
BS 6904:1987 | Guide for cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above |
BS 6184:1981 | Method for measuring partial discharges in instrument transformers |
BS 4727-2:GRP06(1985) : 1985 | GLOSSARY OF ELECTROTECHNICAL POWER TELECOMMUNICATION ELECTRONICS LIGHTING AND COLOUR TERMS - TERMS PARTICULAR TO POWER ENGINEERING - SWITCHGEAR & CONTROLGEAR TERMINOLOGY INCLUDING FUSE TERMINOLOGY |
BS EN 60129:1994 | Specification for alternating current disconnectors and earthing switches |
BS EN 60060-2:1995 | High-voltage test techniques Measuring systems |
IEC 60141-1:1993 | Tests on oil-filled and gas-pressure cables and their accessories - Part 1: Oil-filled, paper or polypropylene paper laminate insulated, metal-sheathed cables and accessories for alternating voltages up to and including 500 kV |
BS EN 60298:1996 | A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.